JCMX shunt trip release
TECHNICAL DATA
JCMX Shunt Trip Release Specifications and Coil Options
The JCMX shunt trip release is an externally energized accessory for opening a compatible breaker. W9 Group’s body text describes fitting it to the left side of compatible MCB / RCBO devices. Confirm the host breaker and coil voltage; the release does not provide remote closing or independent circuit protection.
| Standard | IEC61009-1 , EN61009-1 | |
| Electrical features | Rated voltage Us (V) | AC230, AC400 50/60Hz DC24/DC48 |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 4000 | |
| Poles | 1 Pole (18mm Width) | |
| Insulation voltage Ui (V) | 500 | |
| Dielectric TEST voltage at ind.Freq.for 1 min (kV) | 2 | |
| Pollution degree | 2 | |
| Mechanical features | Electrical life | 4000 |
| Mechanical life | 4000 | |
| Protection degree | IP20 | |
| Reference temperature for setting of thermal element(℃) | 30 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| Installation | Terminal connection type | Cable |
| Terminal size top/bottom for cable | 2.5mm2 / 18-14 AWG | |
| Tightening torque | 2 N*m / 18 In-Ibs. | |
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device |
SELECTION GUIDE
Selecting an MCB Shunt Trip Accessory for Remote Opening
Specify the host breaker model, coil voltage/type, trip command and required indication accessories when requesting a JCMX quotation from W9 Group.
Identify the host breaker
Provide the exact MCB or RCBO model. Confirm mechanical coupling and accessory compatibility before ordering.
Match the release coil
Choose the coil for the control voltage and AC / DC supply. Confirm the order code and terminal diagram.
Design the trip command
Confirm the permitted energization duration and the required control-circuit arrangement; source duty descriptions conflict.
Plan indication separately
If breaker position or fault-trip feedback is needed, confirm a separate compatible contact accessory.
ABOUT W9 GROUP
W9 Group Breaker Accessory Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMX enquiry, contact W9 Group about configuration and matching product documents.

RELATED RESOURCES
JCMX Shunt Trip Wiring and Breaker Compatibility Information
Use W9 Group technical support and the product directory to specify JCMX. Request a datasheet and wiring diagram matching the selected JCMX configuration.
PRODUCT DIRECTORYExplore W9 Group productsBrowse W9 Group models and request the specifications of the selected product
DOCUMENTSW9 Group download centreRequest the current document for your quoted JCMX variant
BUYER FAQ
JCMX Shunt Trip Release FAQs: Coil Duty and Remote Tripping
Find answers about JCMX selection, configuration and ordering.
What does a JCMX shunt trip release do?
Applying the specified control voltage to the release trips a compatible host breaker open. Confirm the host breaker and wiring diagram.
Can JCMX remotely close the breaker?
No remote-closing function is established. It is described as a shunt trip release for opening; confirm a separate operating mechanism if closing is required.
Which coil voltages are listed?
The AC and DC coil-voltage choices appear in the specifications. Confirm the particular coil code and supply frequency rather than assuming one unit accepts all listed supplies.
Will JCMX fit any MCCB, MCB or RCBO?
No. The title mentions MCCB, while the body describes MCB / RCBO mounting. Confirm exact compatible host codes with W9 Group.
Can the coil remain energized continuously?
The page contains conflicting duty descriptions. Confirm permitted pulse duration, continuous-duty capability and required control wiring from the matching instructions.
Does the release provide trip feedback or overload protection?
No auxiliary feedback is listed, and the accessory is not an independent overload or short-circuit protective device. Confirm separate indication and the host breaker’s protection functions.
What is needed for a JCMX quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.
PRODUCT ENQUIRY
Request a JCMX Shunt Trip Release Quotation
Tell W9 Group your host breaker model, coil voltage/type, trip command and required indication accessories, quantity and destination market so the selected configuration can be identified.


































