산업용 제품

  • MCCB 차단기 WLM6LY-160A-4300 4P WLM6L 시리즈 RCCB 지상 누설 보호 타입 400V 160A 3극 4극 갤러리 이미지 1
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6
  • MCCB 차단기 WLM6LY-160A-4300 4P WLM6L 시리즈 RCCB 지상 누설 보호 타입 400V 160A 3극 4극 갤러리 이미지 1
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6

WLM6LY-160 earth leakage MCCB

The WLM6LY-160 earth leakage MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

WLM6LY-160 Earth Leakage MCCB Specifications

The WLM6LY-160 earth leakage MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6LY-160 product specifications
모델 WLM6LY-160
제품 카테고리 Earth leakage molded case circuit breaker
총칭된 전류 160 A
Catalog current choices 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A
Summary pole options 3P / 4P; confirm the complete order code
Voltage selection 400 V AC appears in the summary and table; confirm voltage for the selected configuration
Overcurrent release listed Thermal
Leakage release listed 전자적
Residual-current type listed AC; confirm suitability for the expected waveform
절연 전압 Ui 1000 V
임펄스 저항 전압 Uimp 8 kV
Leakage alarm without tripping Shown as an option; confirm availability and intended alarm / trip mode
Standard listed IEC / EN 60947-2; request applicable model documents

선정 가이드

Selecting a 160A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-160 quotation from W9 Group.

01

Choose the ordered current

The 160 A page lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-160: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

W9 그룹 소개

W9 Group 160A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-160 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

WLM6LY-160 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-160. Request a datasheet and wiring diagram matching the selected WLM6LY-160 configuration.

구매자 FAQ

WLM6LY-160 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-160 selection, configuration and ordering.

Which current choices are listed for WLM6LY-160?

The summary identifies 160 A. The frame schedule lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-160 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a WLM6LY-160 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기