  • Выключатель MCCB WLM6LY-160A-4300 серии WLM6L с четырьмя выводами, тип защиты от утечки электропитания, 400 В, 160 А, 3 полюса, 4 полюса
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6
  • Выключатель MCCB WLM6LY-160A-4300 серии WLM6L с четырьмя выводами, тип защиты от утечки электропитания, 400 В, 160 А, 3 полюса, 4 полюса
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6

MCCB WLM6LY-160 для утечки электроэнергии

The WLM6LY-160 earth leakage MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

WLM6LY-160 Earth Leakage MCCB Specifications

Электрическая автоматическая выключательная коробка WLM6LY-160 от W9 Group имеет общий ток срабатывания 160 А и варианты подключения 3P/4P. В таблице указаны параметры термоперегрева и электронного срабатывания утечки. Для конкретной модели необходимо указать требуемый остаточный ток срабатывания, расположение полюсов и режим работы при замыкании.

Преобразователь с корпусом в форме уплотнительной пробки WLM6LY 160
Номинальный ток (А) выключателя 40°C Тип фиксировки 16-20-25-30-32-40-50-60-63-75-80-90-100-125-140-150-160
Тип LCD 16-20-25-30-32-40-50-60-63-75-80-90-100-125-140-150-160
Определенная изоляционная напряженность Ui (В) 1000
Определенная импульсная прочность на напряжение (kV) 8
Определенная рабочая напряженность Ue(V), переменный ток 50/60 Гц AC230V (2P)/AC400 (3P, 3P+N, 4P)
Код прорыва пропускной способности C S M H
Число столбов 2P ■ ■ ■ ■
3P ■ ■ ■ ■
4P ■ ■ ■ ■
Определён как наилучший
прекращение замыкания
мощность ИКУ (кА)
AC380/400/415В 15 20 25 35
AC380/400/415В 10 15 25 35
Определенная остаточная прочность при скручивании и разрыве
Я△м(А)
AC220/230/240В – – 12.5 12.5
Ограничение времени бездействия △ t (мс) 0,06 с/0,2 с/0,5 с/1 с
Функция сигнализации утечки без срабатывания □
тип срабатывания при перегрузке Тип Themal
Тип срабатывания утечки Электронный тип
Тип остаточного тока AC
Стандартный IEC/EN 60947-2
Категория использования A
Температура окружающей среды -40℃ ~+70 ℃
Безопасность изоляции ■
Расстояние искрения 0
Механический срок службы
(Ко второй переработке)
Поддержание работоспособности 15000
Электрическая жизнь
(Ко второй переработке)
AC415V,In 8000
AC690V,В 2000
Выпускаемые единицы
Установка и подключение
Исправлено Передний контакт ■
Задний разъём ■
Пластиковый адаптер Передний контакт ■
Задний разъём ■
Развертывание Передний контакт –
Задний разъём –
DIN-рейлинги Передний контакт ■
Размер
Размер (мм)
Ш×В×Г
Ширина (2P/3P/4P) 60/90/120
Высота 155
Глубина 68
Масса
Защита от распространения 2P –
3P 1.45
4P 1.592

ГИД ПО ОТБЕРЕЖЕ

Selecting a 160A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-160 quotation from W9 Group.

01

Choose the ordered current

The 160 A page lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-160: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

WLM6LY-160 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-160. Request a datasheet and wiring diagram matching the selected WLM6LY-160 configuration.

Часто задаваемые вопросы покупателей

WLM6LY-160 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-160 selection, configuration and ordering.

Which current choices are listed for WLM6LY-160?

The summary identifies 160 A. The frame schedule lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-160 quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a WLM6LY-160 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.