WLM6LY-125 지상 누설 MCCB

The WLM6LY-125 earth leakage MCCB is listed by W9 Group with a 125 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

WLM6LY-125 Earth Leakage MCCB Specifications

The WLM6LY-125 earth leakage MCCB is listed by W9 Group with a 125 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6L Moulded Case Circuit Breaker 125
회로 차단기의 정격 전류 (A), 40℃ 기준 유형 수정 16-20-25-30-32-40-50-60-63-75-80-90-100-125
LCD 유형 –
등급된 절연 전압 Ui(V) 1000
정격 인덕션 저항 전압 (kV) 8
운용 전압 Ue(V), AC 50/60Hz AC230V(2P)/AC400(3P、3P+N、4P)
차단 용량 코드 C S M H
폴 수 2P ■ ■ ■ ■
3P ■ ■ ■ ■
4P ■ ■ ■ ■
최고 등급
단락 차단
용량 Icu(kA)
AC380/400/415V 5 8 25 35
AC380/400/415V 3 5 18 35
정격 잔류 차단 및 개폐 용량
나는(kA)
AC220/230/240V 12.5 12.5 12.5 12.5
비작동 시간 제한 Δt (ms) 0.06초/0.2초/0.5초/1초
누출 경보 비작동 기능 □
과전류 트립형 열적 유형
누전 트립형 전자식
잔류 전류형 에이씨
표준 IEC/EN 60947-2
이용 범주 A
기온 -40℃ ~+70 ℃
절연재의 안전성 ■
회전 거리 0
기계적 수명
(CO 재활용)
보수 15000
전기 수명
(CO 재활용)
AC415V,In 8000
AC690V,In 2000
릴리스 단위
장착 및 연결
수정됨 전면 연결 ■
후면 연결 ■
플러그인 전면 연결 ■
후면 연결 ■
끌어내는 것 전면 연결 –
후면 연결 –
DIN 레일 전면 연결 ■
차원
치수 (mm)
W×H×D
폭 (2P/3P/4P) 50/75/100
키 130
깊이 68
체중
유통 보호 2P –
3P 0.913
4P 1.161

선정 가이드

Selecting a 125A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-125 quotation from W9 Group.

01

Choose the ordered current

The 125 A page lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-125: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

W9 그룹 소개

W9 Group 125A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

WLM6LY-125 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-125. Request a datasheet and wiring diagram matching the selected WLM6LY-125 configuration.

구매자 FAQ

WLM6LY-125 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-125 selection, configuration and ordering.

Which current choices are listed for WLM6LY-125?

The summary identifies 125 A. The frame schedule lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

전압과 차단용량은 어떻게 선택해야 하나요?

극 배열 및 용량 코드에 대한 동작 전압과 Icu/Ics 데이터를 요청하십시오. 설치 전에 요약과 표 간의 불일치 사항을 확인하십시오. 여기에는 범용 고장 정격이 부여되어 있지 않습니다.

What is needed for a WLM6LY-125 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a WLM6LY-125 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기