産業製品

  • MCCB遮断器 WLM6LY-160A-4300 4P WLM6Lシリーズ RCCB 地圧漏洩保護型 400V 160A 3極 4極 ギャラリー画像1
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6
  • MCCB遮断器 WLM6LY-160A-4300 4P WLM6Lシリーズ RCCB 地圧漏洩保護型 400V 160A 3極 4極 ギャラリー画像1
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-160A-4300 4P WLM6L Series RCCB earth leakage protection type 400V 160A 3 poles 4 Poles Gallery image 6

WLM6LY-160 地上漏電MCCB

The WLM6LY-160 earth leakage MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

技術データ

WLM6LY-160 Earth Leakage MCCB Specifications

The WLM6LY-160 earth leakage MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6LY Moulded Case Circuit Breaker 160
回路ブレーカーの定格電流(A)40℃ タイプを修正 16-20-25-30-32-40-50-60-63-75-80-90-100-125-140-150-160
液晶タイプ 16-20-25-30-32-40-50-60-63-75-80-90-100-125-140-150-160
定格絶縁電圧 Ui(V) 1000
定格インパルス耐圧(kV) 8
動作電圧Ue(V)、AC 50/60Hz AC230V(2P)/AC400(3P、3P+N、4P)
断線容量コード C S M H
ポール数 2P ■ ■ ■ ■
3P ■ ■ ■ ■
4P ■ ■ ■ ■
究極の評価
短絡遮断
容量(Icu) (kA)
AC380/400/415V 15 20 25 35
AC380/400/415V 10 15 25 35
定格残留遮断能力
私は△ m(kA)です
AC220/230/240V – – 12.5 12.5
非作動時間の上限 Δt (ms) 0.06秒/0.2秒/0.5秒/1秒
漏れ警報の非作動機能 □
過電流トリップ型 熱式
漏電トリップタイプ 電子タイプ
残留電流型 AC
スタンダード IEC/EN 60947-2
利用カテゴリー A
周囲温度 -40℃ ~+70 ℃
断熱材の安全性 ■
アーチング距離 0
機械的寿命
(CO リサイクル)
メンテナンス 15000
電気寿命
(CO リサイクル)
AC415V、イン 8000
AC690V、イン 2000
リリースユニット
取り付けと接続
修正済み フロント接続 ■
リア接続 ■
プラグイン フロント接続 ■
リア接続 ■
引き伸ばす フロント接続 –
リア接続 –
DINレール フロント接続 ■
寸法
寸法(mm)
W×H×D
幅(2P/3P/4P) 60/90/120
身長 155
奥行き 68
重量
配電保護 2P –
3P 1.45
4P 1.592

選定ガイド

Selecting a 160A Earth Leakage MCCB by Sensitivity and Poles

W9グループにWLM6LY-160の見積りを依頼する際には、選択した定格電流、極数、漏れ感度および遅延時間、波形要件、電圧、故障耐容量、および警報モードを指定してください。.

01

選択した電流を指定してください

160 Aのページには、16 A、20 A、25 A、30 A、32 A、40 A、50 A、60 A、63 A、75 A、80 A、90 A、100 A、125 A、140 A、150 A、160 Aが記載されています。選択した定格電流および極数構成を含む、製品型式末尾をご確認ください。.

02

漏電保護を指定する

要求される感度、波形応答および遅延を確保してください。実際の設定可能な値を確認してください。残留電流遮断容量は感度設定ではありません。.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-160: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

W9 GROUPについて

W9 Group 160A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-160 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

WLM6LY-160 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-160. Request a datasheet and wiring diagram matching the selected WLM6LY-160 configuration.

購入者のよくある質問

WLM6LY-160 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-160 selection, configuration and ordering.

Which current choices are listed for WLM6LY-160?

The summary identifies 160 A. The frame schedule lists 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 90, 100, 125, 140, 150, 160 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-160 quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a WLM6LY-160 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ