産業製品

  • MCCB遮断器 WLM6LY-630A-4300 4P WLM6L シリーズ 地電漏えい保護型遮断器 400V 630A 3 極 4 極 ギャラリー画像 1
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 6
  • MCCB遮断器 WLM6LY-630A-4300 4P WLM6L シリーズ 地電漏えい保護型遮断器 400V 630A 3 極 4 極 ギャラリー画像 1
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 6

WLM6LY-630 earth leakage MCCB

The WLM6LY-630 earth leakage MCCB is listed by W9 Group with a 630 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

技術データ

WLM6LY-630 Earth Leakage MCCB Specifications

The WLM6LY-630 earth leakage MCCB is listed by W9 Group with a 630 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6LY-630 product specifications
モデル WLM6LY-630
製品カテゴリー Earth leakage molded case circuit breaker
概要評価電流 630 A
Catalog current choices 400, 500, 630 A
Summary pole options 3P / 4P; confirm the complete order code
Voltage selection 400 V AC appears in the summary and table; confirm voltage for the selected configuration
Overcurrent release listed Thermal
Leakage release listed 電子機器
Residual-current type listed AC; confirm suitability for the expected waveform
絶縁電圧 Ui 1000 V
インパルス耐圧 Uimp 8 kV
Leakage alarm without tripping Shown as an option; confirm availability and intended alarm / trip mode
Standard listed IEC / EN 60947-2; request applicable model documents

選定ガイド

Selecting a 630A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-630 quotation from W9 Group.

01

Choose the ordered current

The 630 A page lists 400, 500, 630 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-630: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

W9 GROUPについて

W9 Group 630A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-630 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

WLM6LY-630 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-630. Request a datasheet and wiring diagram matching the selected WLM6LY-630 configuration.

購入者のよくある質問

WLM6LY-630 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-630 selection, configuration and ordering.

Which current choices are listed for WLM6LY-630?

The summary identifies 630 A. The frame schedule lists 400, 500, 630 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-630 quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a WLM6LY-630 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ