JCMS100 main switch isolator specifications
The JCMS100 main switch isolator is offered by W9 Group for manual switching and isolation. Specify the ordered current, pole arrangement and load duty using the matching switch schedule. It does not replace automatic overload or short-circuit protection.
| 표준 | IEC/EN 60947-3 | |
|
전기 기능 |
정격 전류(A) | 32,40,50,63,80,100,125 |
| 폴란드인 | 1P, 2P, 3P, 4P | |
| 정격 전압 Ue(V) | 230/400~240/415 | |
| 절연 전압 Ui(V) | 500 | |
| 정격 주파수 | 50/60Hz | |
| 정격 임펄스 내전압(1.2/50) Uimp (V) | 4,000 | |
| 정격 단시간 내전 전류 lcw | 12le, 1s | |
| Rated making and breaking capacity | 3le, 1.05Ue, cosφ=0.65 | |
| Rated short circuit making capacity | 20le, t=0.1s | |
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |
| 오염 정도 | 2 | |
| Uilization category | AC-22A | |
|
기계적 특징 |
전기 수명 | 1500 |
| 기계적 수명 | 8500 | |
| 접촉 위치 표시기 | 네 | |
| 보호 수준 | IP20 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| 설치 | 터미널 연결 유형 | 케이블/U형 버스바/핀형 버스바 |
| 케이블의 상단/하단 터미널 사이즈 |
50mm2 / 18-1/0 AWG |
|
| 버스바용 터미널 사이즈 상단/하단 |
35mm2 / 18-2 AWG |
|
| 강력한 토크 |
2.5 N*m / 22 In-Ibs. |
|
| 장착 | DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착 | |
| 연결 | From top and bottom |
선정 가이드
JCMS100 manual switch disconnector selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCMS100 quotation from W9 Group.
스위칭 업무 정의
로드 유형, 공급 전압 및 필요한 작동 부하를 제공합니다. 활용 범주와 허용되는 전환 조건 확인.
현재 및 폴 선택
주문된 전류 및 폴 구성과 회로를 일치시켜야 합니다. 이 과정에는 중립 전환 요구 사항도 포함됩니다.
위치 결함 보호 기능
업스트림 보호 장치 및 잠재적 결함 전류를 명시합니다. 제조업체의 단락 시공 정보 요청.
박스 및 출입구 확인
차원, 터미널 세부 정보, 설치 및 작동 및 유지보수 접근에 대한 확인을 하십시오. 잠금 지침은 별도로 요청하십시오.
W9 그룹 소개
W9 Group support for JCMS100 switch isolator
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMS100 enquiry, contact W9 Group about configuration and matching product documents.

관련 자료
JCMS100 Switch Isolator Connection Diagrams
Use technical support and related products to specify JCMS100. Request a datasheet and wiring diagram matching the selected JCMS100 configuration.
구매자 FAQ
JCMS100 main switch selection FAQs
Find answers about JCMS100 selection, configuration and ordering.
Is JCMS100 a circuit breaker?
It is listed as a main switch isolator. Confirm separate automatic overload and short-circuit protection for the circuit; manual switching is a different function.
Which rated current should I specify?
Confirm the exact current option and order code with W9 Group. The product designation and the full schedule should be checked together before ordering.
Which pole options are listed?
The supplier lists one through four poles. Confirm which conductors are switched and the neutral arrangement from the exact wiring diagram.
What does the utilization category mean?
The original table lists AC-22A. Confirm that the actual load and switching duty fall within the applicable rating; a current value alone does not establish every load-switching duty.
Can the isolator be locked off?
The summary lists a locking kit. Confirm the compatible kit, locking position and installation procedure for the exact ordered switch.
Does the short-circuit figure replace upstream protection?
No. Confirm whether the stated figure is a withstand, making or conditional rating, and obtain the required backup-device coordination schedule.
What is needed for a JCMS100 quotation?
필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.
제품 문의
Request a JCMS100 main switch isolator quotation
W9 Group에 주문번호, 회로 사용 목적, 설치 조건 및 필요한 서류, 수량 및 판매처를 알려주시면 선택된 구성이 확인될 수 있습니다.