JCH2-125 메인 스위치 이오실레이터
기술 데이터
JCH2-125 125A Main Switch Isolator Specifications
The JCH2-125 main switch isolator is a switch-disconnector for local isolation in residential and light-commercial distribution. W9 Group lists 1-pole through 4-pole versions, current choices up to 125 A and AC-22A duty. It is a switching and isolation device; provide separate circuit protection.
| 제품 코드 | JCH2- 125 | |||
| 폴 | 1 극 | 2번 기둥 | 3번 기둥 | 4 Pole |
| 표준 | IEC 60947-3 , EN 60947-3 | |||
|
Electrical features |
Rated current In (A) | 32 ,40 ,50 ,63 ,80 , 100 , 125 | ||
| 폴란드인 | 1P , 2P , 3P , 4P | |||
| Rated voltage Ue (V) | 230/400~ 240/415 | |||
| Insulation voltage Ui (V) | 500 | |||
| Rated frequency | 50/60Hz | |||
| Rated impulse withstand voltage(1 .2/50) Uimp (V) | 4000 | |||
| 정격 단시간 내전 전류 lcw | 12le , 1s | |||
| Rated making and breaking capacity | ||||
| Rated short circuit making capacity | 20le , t=0. 1s | |||
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |||
| 오염 정도 | 2 | |||
| Uilization category | AC-22A | |||
| Mechanicalfeatures | Electrical life | 1500 | ||
| Mechanical life | 8500 | |||
| Contact position indicator | 네 | |||
| Protection degree | IP 20 | |||
| Reference temperature for setting of thermal element(℃) | 30 | |||
| Ambient temperature (with daily average ≤35℃) | -5. . .+40 ℃ | |||
| Storage temperation (℃) | -25…+70 ℃ | |||
| 설치 | Terminal connection type | Cable/U-type busbar/Pin-type busbar | ||
| Terminal size top/bottom for cable | 50mm² / 18- 1/0 AWG | |||
| Terminal size top/bottom for busbar | 35mm² / 18-2 AWG | |||
| Tightening torque | 2.5 N*m / 22 In-Ibs. | |||
| 장착 | On DIN rail EN 60715 (35mm) | |||
| 연결 | From top and bottom | |||
| 표준 | IEC/EN 60947-3 | |
|
전기 기능 |
정격 전류(A) | 32,40,50,63,80,100,125 |
| 폴란드인 | 1P, 2P, 3P, 4P | |
| 정격 전압 Ue(V) | 230/400~240/415 | |
| 절연 전압 Ui(V) | 500 | |
| 정격 주파수 | 50/60Hz | |
| 정격 임펄스 내전압(1.2/50) Uimp (V) | 4,000 | |
| 정격 단시간 내전 전류 lcw | 12le, 1s | |
| Rated making and breaking capacity | 3le, 1.05Ue, cosφ=0.65 | |
| Rated short circuit making capacity | 20le, t=0.1s | |
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |
| 오염 정도 | 2 | |
| Uilization category | AC-22A | |
|
기계적 특징 |
전기 수명 | 1500 |
| 기계적 수명 | 8500 | |
| 접촉 위치 표시기 | 네 | |
| 보호 수준 | IP20 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| 설치 | 터미널 연결 유형 | 케이블/U형 버스바/핀형 버스바 |
| 케이블의 상단/하단 터미널 사이즈 |
50mm2 / 18-1/0 AWG |
|
| 버스바용 터미널 사이즈 상단/하단 |
35mm2 / 18-2 AWG |
|
| 강력한 토크 |
2.5 N*m / 22 In-Ibs. |
|
| 장착 | DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착 | |
| 연결 | From top and bottom |
선정 가이드
Selecting a 2 Pole or 4 Pole Switch Disconnector
Specify the current, poles, supply voltage, load duty, enclosure and locking requirements when requesting a JCH2-125 quotation from W9 Group.
Choose the current rating
The table includes 32–125 A choices. Confirm the ordered current and its load-duty suitability.
Match poles and supply
Specify the required live and neutral isolation arrangement. Request the connection diagram for the selected pole version.
Check isolation and locking
Confirm contact indication, the locking accessory and the isolation procedure required by the installation.
Provide circuit protection
Coordinate a suitable breaker or fuse separately. Confirm load switching duty and short-circuit withstand data with W9 Group.
W9 그룹 소개
W9 Group Main Switch Isolator Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCH2-125 enquiry, contact W9 Group about configuration and matching product documents.

관련 자료
JCH2-125 Main Switch Isolator Wiring and Mounting Information
Use W9 Group technical support and the product directory to specify JCH2-125. Request a datasheet and wiring diagram matching the selected JCH2-125 configuration.
구매자 FAQ
Main Switch Isolator FAQs: Poles, Load Duty and Circuit Protection
Find answers about JCH2-125 selection, configuration and ordering.
Is JCH2-125 a circuit breaker?
It is listed as a main switch isolator / switch-disconnector. It does not provide overload or short-circuit trip protection.
What current ratings are listed?
The technical table lists 32, 40, 50, 63, 80, 100 and 125 A. Confirm the available order code and current marking.
Can I choose a 2-pole or 4-pole main switch?
Yes, the source lists 1P, 2P, 3P and 4P versions. Confirm the required supply and neutral isolation arrangement.
What utilization category is stated?
The supplier lists AC-22A. Confirm that the load duty and operating conditions are covered by the offered switch rating.
Does IP20 make the switch suitable for outdoor exposure?
Do not use IP20 as evidence of outdoor weather protection. Confirm the enclosure and environmental requirements for the installation.
어떤 설치 서류가 필요합니까?
Request the dimensions, terminal and busbar details, locking instructions and connection diagram for the selected version. Confirm short-circuit withstand values because source sections differ.
What is needed for a JCH2-125 quotation?
필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.
제품 문의
Request a JCH2-125 Main Switch Isolator Quotation
Tell W9 Group your current, poles, supply voltage, load duty, enclosure and locking requirements, quantity and destination market so the selected configuration can be identified.