آیوسیلاتور اصلی JCMS100
اطلاعات فنی
JCMS100 main switch isolator specifications
The JCMS100 main switch isolator is offered by W9 Group for manual switching and isolation. Specify the ordered current, pole arrangement and load duty using the matching switch schedule. It does not replace automatic overload or short-circuit protection.
| استاندارد | IEC/EN 60947-3 | |
|
ویژگیهای الکتریکی |
مقاومت جریان ورودی (A) | 32,40,50,63,80,100,125 |
| پوشندگان لهستانی | 1P, 2P, 3P, 4P | |
| فشار ولتاژ Ue (V) | 230/400~240/415 | |
| ولتاژ عایق بندی Ui (V) | 500 | |
| فراوانی رتبهبندی شده | ۵۰/۶۰ هرتز | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 4,000 | |
| Rated short-time withstand current lcw | 12le, 1s | |
| Rated making and breaking capacity | 3le, 1.05Ue, cosφ=0.65 | |
| Rated short circuit making capacity | 20le, t=0.1s | |
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |
| سطح آلودگی | 2 | |
| Uilization category | AC-22A | |
|
ویژگیهای مکانیکی |
زندگی الکتریکی | 1500 |
| زمان کارکرد مکانیکی | 8500 | |
| نمایشگر موقعیت تماس | بله | |
| سطح حفاظت | IP20 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| ارائه نصب | نوع اتصال ترمینال | کابل/پیوستهای U-type/پیوستهای Pin-type |
| ابعاد بالایی/پایینی ترمینال برای کابل |
50mm2 / 18-1/0 AWG |
|
| ابعاد پایانه بالایی/پایینی برای Busbar |
35mm2 / 18-2 AWG |
|
| تنگ کردن گشتاور |
2.5 N*m / 22 In-Ibs. |
|
| قرارگیری | بر روی ریل DIN EN 60715 (35 میلی متر) با استفاده از دستگاه سریع اتصال | |
| اتصال | From top and bottom |
راهنمای انتخاب
JCMS100 manual switch disconnector selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCMS100 quotation from W9 Group.
تعریف وظیفه سوئیچینگ
نوع بار، ولتاژ ورودی و وظیفه کاری مورد نیاز را مشخص کنید. دستهبندی استفاده و شرایط سوئیچینگ مجاز را تأیید کنید.
انتخاب فعلی و قطبها
ارتباط ترتیب جریان و پیک موجود با مدار را شاملشود، از جمله هر گونه الزامی در رابطه با تغییر مدار به صورت خنثی.
تنسيق حفاظت از خطاهای فنی
دستگاه حفاظتی بالادست و جریان خطا احتمالی را مشخص کنید. اطلاعات هماهنگی اتصال کوتاه را از سازنده درخواست کنید.
بررسی محوطه و دسترسی
ابعاد، جزئیات ترمینال، نصب و دسترسی برای عملیات و نگهداری را تأیید کنید. هر گونه دستورالعمل مربوط به قفل کردن را جداگانه درخواست کنید.
درباره W9 Group
W9 Group support for JCMS100 switch isolator
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMS100 enquiry, contact W9 Group about configuration and matching product documents.

منابع مرتبط
JCMS100 Switch Isolator Connection Diagrams
Use technical support and related products to specify JCMS100. Request a datasheet and wiring diagram matching the selected JCMS100 configuration.
محصول مرتبطWLLP-160 isolating switchعملکرد و پیکربندی را مقایسه کنید؛ درخواست امتیازات جداگانه برای مدلها را ارائه دهید
اسنادمرکز دانلود W9 GroupRequest the current document for your quoted JCMS100 variant
سوالات متداول خریداران
JCMS100 main switch selection FAQs
Find answers about JCMS100 selection, configuration and ordering.
Is JCMS100 a circuit breaker?
It is listed as a main switch isolator. Confirm separate automatic overload and short-circuit protection for the circuit; manual switching is a different function.
Which rated current should I specify?
Confirm the exact current option and order code with W9 Group. The product designation and the full schedule should be checked together before ordering.
Which pole options are listed?
The supplier lists one through four poles. Confirm which conductors are switched and the neutral arrangement from the exact wiring diagram.
What does the utilization category mean?
The original table lists AC-22A. Confirm that the actual load and switching duty fall within the applicable rating; a current value alone does not establish every load-switching duty.
Can the isolator be locked off?
The summary lists a locking kit. Confirm the compatible kit, locking position and installation procedure for the exact ordered switch.
Does the short-circuit figure replace upstream protection?
No. Confirm whether the stated figure is a withstand, making or conditional rating, and obtain the required backup-device coordination schedule.
What is needed for a JCMS100 quotation?
اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونهها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.
سؤال و جواب درباره محصول
Request a JCMS100 main switch isolator quotation
به گروه W9 کد کامل سفارش، وظایف مدار، شرایط نصب و مدارک مورد نیاز، تعداد و بازار مقصد را اطلاع دهید تا بتوان پیکربندی انتخاب شده را شناسایی کرد.