JCMS100 main switch isolator specifications
The JCMS100 main switch isolator is offered by W9 Group for manual switching and isolation. Specify the ordered current, pole arrangement and load duty using the matching switch schedule. It does not replace automatic overload or short-circuit protection.
| Стандартный | IEC/EN 60947-3 | |
|
Электрические характеристики |
Максимальный ток в А (А) | 32,40,50,63,80,100,125 |
| Поляки | 1P, 2P, 3P, 4P | |
| Номинальное напряжение Ue (V) | 230/400~240/415 | |
| Изоляционное напряжение Ui (В) | 500 | |
| Определенная частота | 50/60 Гц | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 4,000 | |
| Rated short-time withstand current lcw | 12le, 1s | |
| Rated making and breaking capacity | 3le, 1.05Ue, cosφ=0.65 | |
| Rated short circuit making capacity | 20le, t=0.1s | |
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |
| Уровень загрязнения | 2 | |
| Uilization category | AC-22A | |
|
Механические характеристики |
Электрическая жизнь | 1500 |
| Механический срок службы | 8500 | |
| Индикатор положения контакта | Да | |
| Степень защиты | IP20 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| Установка | Тип терминального соединения | Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками |
| Верхний и нижний размер терминала для кабеля |
50mm2 / 18-1/0 AWG |
|
| Высокоскоростной терминал для разветвления кабелей |
35mm2 / 18-2 AWG |
|
| Усиление крутящего момента |
2.5 N*m / 22 In-Ibs. |
|
| Установка | На DIN-рейле EN 60715 (35 мм) с помощью устройства с быстрым зажимом | |
| Вставка | From top and bottom |
ГИД ПО ОТБЕРЕЖЕ
JCMS100 manual switch disconnector selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCMS100 quotation from W9 Group.
Определите обязанности по переключению
Укажите тип нагрузки, напряжение питания и требуемую рабочую нагрузку. Проверьте категорию использования и допустимые условия переключения.
Выберите «Текущий и полюсы»
Совместите заказанную схему тока и конфигурацию полюсов с цепями, включая любые требования к коммутации нейтральных выводов.
Координирование защиты от повреждений
Укажите источник защиты и предполагаемый ток короткого замыкания. Запросите информацию о координации замыкания от производителя.
Проверьте корпус и доступ к нему
Уточните размеры, детали крепления, способы монтажа и доступ к устройству для обслуживания и ремонта. Запросите инструкции по блокировке отдельно.
О W9 GROUP
W9 Group support for JCMS100 switch isolator
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMS100 enquiry, contact W9 Group about configuration and matching product documents.

СВЯЗАННЫЕ РЕСУРСЫ
JCMS100 Switch Isolator Connection Diagrams
Use technical support and related products to specify JCMS100. Request a datasheet and wiring diagram matching the selected JCMS100 configuration.
СВЯЗАННЫЕ ПРОДУКТЫWLLP-160 isolating switchСравните функциональность и конфигурацию; запросите отдельную оценку модели
ДОКУМЕНТЫЦентр загрузки программ W9 GroupRequest the current document for your quoted JCMS100 variant
Часто задаваемые вопросы покупателей
JCMS100 main switch selection FAQs
Find answers about JCMS100 selection, configuration and ordering.
Is JCMS100 a circuit breaker?
It is listed as a main switch isolator. Confirm separate automatic overload and short-circuit protection for the circuit; manual switching is a different function.
Which rated current should I specify?
Confirm the exact current option and order code with W9 Group. The product designation and the full schedule should be checked together before ordering.
Which pole options are listed?
The supplier lists one through four poles. Confirm which conductors are switched and the neutral arrangement from the exact wiring diagram.
What does the utilization category mean?
The original table lists AC-22A. Confirm that the actual load and switching duty fall within the applicable rating; a current value alone does not establish every load-switching duty.
Can the isolator be locked off?
The summary lists a locking kit. Confirm the compatible kit, locking position and installation procedure for the exact ordered switch.
Does the short-circuit figure replace upstream protection?
No. Confirm whether the stated figure is a withstand, making or conditional rating, and obtain the required backup-device coordination schedule.
What is needed for a JCMS100 quotation?
Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.
ЗАЯВКА О ПОКУПКЕ ПРОДУКТА
Request a JCMS100 main switch isolator quotation
Пожалуйста, сообщите компании W9 Group свой полный номер заказа, информацию о схеме подключения, условиях установки и необходимых документах, количество и место назначения рынка, чтобы можно было идентифицировать выбранную конфигурацию.