JC3RH-B Type B RCCB
The JC3RH-B Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code. Request the selected configuration and matching technical documents from W9 Group.
- Type B RCCB
- Smooth DC residual-current detection
- Electromagnetic operation
JC3RH-B Type B protection where DC leakage can occur
The JC3RH-B detects smooth DC residual current as well as leakage on AC circuits. This distinction matters when selecting protection for a load with power electronics: the rated current alone does not identify the waveforms an RCCB can detect.






TECHNICAL DATA
JC3RH-B Type B RCCB for AC, Pulsating DC and Smooth DC Residual Currents
The JC3RH-B Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code.
| Standard | IEC62423 & IEC61008-1 | |
|
Electrical features |
Type (wave form of the earth leakage sensed) | B |
| Rated current In | 25A, 40A, 63A, 80A, 100A | |
| Poles | 1P+N, 3P+N | |
| Rated voltage Ue | 1P+N:230V/240V~; 3P+N:400V/415V~; | |
| Rated sensitivity I∆n | 0.03A, 0.1A, 0.3A | |
| Insulation voltage Ui | 500V | |
| Rated residual making and breaking capacity I∆m | 500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A | |
| Short-circuit current Inc=I∆c | 6kA,10kA | |
| SCPD fuse | 10000A | |
| break time under I∆n | ≤0.1 S | |
| Rated frequency | 50Hz | |
| Rated impulse withstand voltage(1.2/50) Uimp | 4,000V | |
| Dielectric test voltage at ind. Freq. for 1 min | 2.5 kV | |
| Pollution degree | 2 | |
|
Mechanical features |
Electrical life | 2, 000 |
| Mechanical life | 10,000 | |
| Fault current indicator | Yes | |
| Protection degree | IP20 | |
| Ambient temperature (with daily average≤35°C) | -25°C…+40°C | |
| Storage temperation | -25°C…+70°C | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25/35 mm² | |
| 18-3/18-2 AWG | ||
| Terminal size top/bottom for busbar | 10/16 mm² | |
| 18-8/18-5 AWG | ||
| Tightening torque | 2.5 N·m | |
| 22 In-Ibs. | ||
| Mounting | On DIN rail EN 60715 (35mm) | |
| Connection | From top and bottom |
SELECTION GUIDE
How to Select a JC3RH-B Type B RCCB by Poles, Current and Sensitivity
Specify the complete order code, load type, poles, supply voltage, current, sensitivity and backup device when requesting a JC3RH-B quotation from W9 Group.
Use the full B suffix when specifying this device. Match the residual operating current to the circuit and confirm the exact connection diagram for the chosen pole arrangement.
Identify the leakage waveform
Check the load manufacturer requirements for smooth-DC and frequency-dependent residual currents. Confirm the Type B response envelope for the exact device.
Match poles and neutral wiring
Specify 1P+N or 3P+N and the actual supply voltage. Request the neutral-terminal, supply and load connection diagram.
Choose current and sensitivity
Select rated current and residual-current sensitivity separately. Confirm the protection objective and upstream/downstream trip-time coordination.
Check backup and application rules
Request the permitted backup protective device and conditional short-circuit data. For inverter or charging circuits, include the equipment protection specification.
ABOUT W9 GROUP
W9 Group JC3RH-B Type B Residual Current Circuit Breaker Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH-B enquiry, contact W9 Group about configuration and matching product documents.

Matching a Type B RCCB to the load
Loads with electronic conversion can produce residual currents that differ from mains-frequency AC. Use the complete JC3RH-B code when selecting smooth DC detection. A similar suffix on an application example is not enough to identify the supplied RCCB or its operating threshold.
RELATED RESOURCES
JC3RH-B Type B RCCB Wiring, Trip-Time and Backup-Protection Documents
Use technical support and related products to specify JC3RH-B. Request a datasheet and wiring diagram matching the selected JC3RH-B configuration.
RELATED PRODUCTJC3RH-BSCompare function and configuration; request separate model ratings
DOCUMENTSW9 Group download centreRequest the current document for your quoted JC3RH-B variant
BUYER FAQ
JC3RH-B Type B RCCB FAQs: Smooth DC, Inverter Loads and Selectivity
Find answers about JC3RH-B selection, configuration and ordering.
What does Type B mean on the JC3RH-B RCCB?
Here Type B describes the residual-current waveform response, including smooth DC in the supplier description. It is different from the B overcurrent trip curve used to describe an MCB.
Which current and sensitivity options are listed?
The target table lists 25 A, 40 A, 63 A, 80 A and 100 A, with residual-current sensitivity choices of 0.03 A, 0.1 A and 0.3 A. Confirm the selected combination.
Which supply and pole configurations are available?
The table lists 1P+N at 230/240 V AC and 3P+N at 400/415 V AC, with a rated frequency of 50 Hz. Confirm the offered configuration and neutral connection diagram.
Can I use it with an inverter, rectifier or charging circuit?
The supplier discusses nonlinear loads and smooth-DC leakage. Confirm the equipment maker requirements, residual-current spectrum, local installation rules and exact-model response data; this is not a universal application approval.
Does the RCCB include overload and short-circuit protection?
The target identifies an RCCB and cites residual-current standards. Confirm a separate overcurrent protective device and the specified conditional short-circuit arrangement; do not interpret conditional capacity as integrated overcurrent protection.
Does the BS suffix guarantee selective or time-delayed tripping?
A suffix alone is insufficient. The available shared schedule does not establish a distinct selective curve for every model. Confirm the exact delay class and trip-time data before coordinating devices.
What is needed for a JC3RH-B quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.