JCRD2-125 RCCB

The JCRD2-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 2P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCRD2-125 2 Pole RCCB Specifications

The JCRD2-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 2P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection.

JCRD2-125 product specifications
Модель JCRD2-125
Device category Residual current circuit breaker
Pole options 2P
Current choices reviewed 25, 40, 50, 63, 80, 100 A
Listed operating voltage 230 / 240 V
Residual-current types Type A / Type AC
Sensitivity options 30 / 100 / 300 mA
Overcurrent protection Separate coordinated MCB or fuse required
Установка 35 mm DIN rail
Степень защиты IP20
Standards listed IEC 61008-1 / EN 61008-1; request matching documentation

ГИД ПО ОТБЕРЕЖЕ

Selecting a Type A or Type AC Residual Current Circuit Breaker

Specify the pole count, current, residual-current type, sensitivity, supply voltage and upstream protection when requesting a JCRD2-125 quotation from W9 Group.

01

Match supply and poles

The listed pole options are 2P. Confirm supply voltage, neutral arrangement and the manufacturer’s terminal diagram.

02

Choose type and sensitivity

Specify Type A or Type AC and the required residual-current sensitivity. Confirm the waveform and protection requirements of the circuit.

03

Coordinate overcurrent protection

Select a compatible MCB or fuse and request the manufacturer’s short-circuit coordination data. The RCCB does not replace overcurrent protection.

04

Confirm the offered current

The reviewed current choices include 25, 40, 50, 63, 80, 100 A. Confirm the complete model code and rating for the quoted unit.

Before specifying JCRD2-125: Confirm the exact order code, current, residual-current type and sensitivity, plus upstream short-circuit coordination. The table includes 125 A but the feature text says up to 100 A; confirm any 125 A offer with a matching datasheet.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCRD2-125 RCCB Datasheet and Upstream Protection Information

Use W9 Group technical support and the product directory to specify JCRD2-125. Request a datasheet and wiring diagram matching the selected JCRD2-125 configuration.

Часто задаваемые вопросы покупателей

JCRD2-125 RCCB FAQs: 30mA Options and Overcurrent Coordination

Find answers about JCRD2-125 selection, configuration and ordering.

Is JCRD2-125 an RCCB or an RCBO?

It is listed as an RCCB: residual-current protection without integral overload and short-circuit protection. Use a coordinated MCB or fuse for those functions.

Which pole and voltage arrangement is listed?

The model page lists 2P, with 230 / 240 V. Confirm the selected configuration and neutral connection diagram.

Which residual-current sensitivities are available?

W9 Group lists 30 mA, 100 mA and 300 mA options. Select the sensitivity for the required protection purpose and coordination.

How do I specify Type A or Type AC?

The source lists both options. State the connected equipment and required residual-current waveform response, and confirm the selected type in the quotation.

Does a 6kA figure mean the RCCB protects against overload?

No. A short-circuit figure does not establish integral overcurrent protection. Confirm the conditional short-circuit rating and required upstream protective device.

What installation details should be checked?

The source lists 35 mm DIN-rail mounting and IP20 protection. Confirm terminal sizes, busbar compatibility, connection instructions and enclosure requirements.