JCRD4-125 RCCB

The JCRD4-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 4P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCRD4-125 4 Pole RCCB Specifications

The JCRD4-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 4P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection.

RCD Types of Load
Type AC Resistive, capacitive, inductive loadsImmersion heater, oven / hob with resistive heating elements, electric shower, tungsten / halogen lighting
Type A Single phase with electronic componentsSingle phase inverters, class 1 IT & multimedia equipment, power supplies for class 2 equipment, appliances such as washing machines, lighting controls, induction hobs & EV charging
Type F Frequency controlled equipmentAppliances containing synchronous motors, some class 1 power tools, some air conditioning controllers using variable frequency speed drives
Type B Three phase electronic equipmentInverters for speed control, ups, EV charging where DC fault current is >6mA, PV
Стандартный IEC61008-1 ,  EN61008-1
Electrical
features
Максимальный ток в А (А)  25, 40, 50, 63, 80, 100, 125
Тип Electromagnetic
Тип (форма волны обнаруженного утечка электроэнергии) AC, A, AC-G, A-G, AC-S and A-S are available
Поляки 4 Pole
Номинальное напряжение Ue (V) 400/415
Rated sensitivity I△n 30mA,100mA,300mA are available
Изоляционное напряжение Ui (В) 500
Определенная частота 50/60 Гц
Максимальный пробойной прочность 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Dielectric test voltage at ind. Freq. for 1 min 2.5kV
Уровень загрязнения 2
Mechanical
features
Электрическая жизнь 2, 000
Механический срок службы 2, 000
Индикатор положения контакта Да
Степень защиты IP20
Референтная температура для настройки теплового элемента (℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70
Установка Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25mm2  , 18-3/18-2 AWG
Terminal size top/bottom for Busbar 10/16mm2  ,18-8 /18-5AWG
Усиление крутящего момента 2.5 N*m  /  22 In-Ibs.
Установка На DIN-рейле EN 60715 (35 мм) с помощью устройства с быстрым зажимом
Вставка From top or bottom

ГИД ПО ОТБЕРЕЖЕ

Selecting a Type A or Type AC Residual Current Circuit Breaker

Specify the pole count, current, residual-current type, sensitivity, supply voltage and upstream protection when requesting a JCRD4-125 quotation from W9 Group.

01

Match supply and poles

The listed pole options are 4P. Confirm supply voltage, neutral arrangement and the manufacturer’s terminal diagram.

02

Choose type and sensitivity

Specify Type A or Type AC and the required residual-current sensitivity. Confirm the waveform and protection requirements of the circuit.

03

Coordinate overcurrent protection

Select a compatible MCB or fuse and request the manufacturer’s short-circuit coordination data. The RCCB does not replace overcurrent protection.

04

Confirm the offered current

The reviewed current choices include 25, 40, 50, 63, 80, 100 A. Confirm the complete model code and rating for the quoted unit.

Before specifying JCRD4-125: Confirm the exact order code, current, residual-current type and sensitivity, plus upstream short-circuit coordination. The table includes 125 A but the feature text says up to 100 A; confirm any 125 A offer with a matching datasheet.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCRD4-125 RCCB Datasheet and Upstream Protection Information

Use W9 Group technical support and the product directory to specify JCRD4-125. Request a datasheet and wiring diagram matching the selected JCRD4-125 configuration.

Часто задаваемые вопросы покупателей

JCRD4-125 RCCB FAQs: 30mA Options and Overcurrent Coordination

Find answers about JCRD4-125 selection, configuration and ordering.

Is JCRD4-125 an RCCB or an RCBO?

It is listed as an RCCB: residual-current protection without integral overload and short-circuit protection. Use a coordinated MCB or fuse for those functions.

Which pole and supply arrangement is listed?

This model is listed as 4P. The voltage choices appear in the specifications; confirm the selected voltage and neutral connection diagram in the offered datasheet.

Which residual-current sensitivities are available?

W9 Group lists 30 mA, 100 mA and 300 mA options. Select the sensitivity for the required protection purpose and coordination.

How do I specify Type A or Type AC?

The source lists both options. State the connected equipment and required residual-current waveform response, and confirm the selected type in the quotation.

Does a 6kA figure mean the RCCB protects against overload?

No. A short-circuit figure does not establish integral overcurrent protection. Confirm the conditional short-circuit rating and required upstream protective device.

What installation details should be checked?

The source lists 35 mm DIN-rail mounting and IP20 protection. Confirm terminal sizes, busbar compatibility, connection instructions and enclosure requirements.

What is needed for a JCRD4-125 quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCRD4-125 RCCB Quotation

Tell W9 Group your pole count, current, residual-current type, sensitivity, supply voltage and upstream protection, quantity and destination market so the selected configuration can be identified.