회로 보호 제품

  • MCCB 차단기 RCD 잔류 전류 차단기 JCRD4-125 4극 타입 AC 또는 Type A RCCB
  • MCCB circuit breaker RCD residual current circuit breaker JCRD4-125 4 Pole Type AC or Type A RCCB Gallery image 2
  • MCCB 차단기 RCD 잔류 전류 차단기 JCRD4-125 4극 타입 AC 또는 Type A RCCB
  • MCCB circuit breaker RCD residual current circuit breaker JCRD4-125 4 Pole Type AC or Type A RCCB Gallery image 2

JCRD4-125 RCCB

The JCRD4-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 4P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JCRD4-125 4 Pole RCCB Specifications

The JCRD4-125 RCCB is a residual current circuit breaker for earth-leakage protection. W9 Group lists 4P, Type A or Type AC and 30 / 100 / 300 mA sensitivity choices. Specify a coordinated MCB or fuse for overload and short-circuit protection.

RCD Types of Load
Type AC Resistive, capacitive, inductive loadsImmersion heater, oven / hob with resistive heating elements, electric shower, tungsten / halogen lighting
Type A Single phase with electronic componentsSingle phase inverters, class 1 IT & multimedia equipment, power supplies for class 2 equipment, appliances such as washing machines, lighting controls, induction hobs & EV charging
Type F Frequency controlled equipmentAppliances containing synchronous motors, some class 1 power tools, some air conditioning controllers using variable frequency speed drives
Type B Three phase electronic equipmentInverters for speed control, ups, EV charging where DC fault current is >6mA, PV
표준 IEC61008-1 ,  EN61008-1
Electrical
features
정격 전류(A)  25, 40, 50, 63, 80, 100, 125
형태 Electromagnetic
형태(지하 배수관에서 감지된 파형) AC, A, AC-G, A-G, AC-S and A-S are available
폴란드인 4 Pole
정격 전압 Ue(V) 400/415
Rated sensitivity I△n 30mA,100mA,300mA are available
절연 전압 Ui(V) 500
정격 주파수 50/60Hz
최대 절단 용량 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Dielectric test voltage at ind. Freq. for 1 min 2.5kV
오염 정도 2
Mechanical
features
전기 수명 2, 000
기계적 수명 2, 000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2  , 18-3/18-2 AWG
버스바용 터미널 사이즈 상단/하단 10/16mm2  ,18-8 /18-5AWG
강력한 토크 2.5 N*m  /  22 In-Ibs.
장착 DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착
연결 From top or bottom

선정 가이드

Selecting a Type A or Type AC Residual Current Circuit Breaker

Specify the pole count, current, residual-current type, sensitivity, supply voltage and upstream protection when requesting a JCRD4-125 quotation from W9 Group.

01

Match supply and poles

The listed pole options are 4P. Confirm supply voltage, neutral arrangement and the manufacturer’s terminal diagram.

02

Choose type and sensitivity

Specify Type A or Type AC and the required residual-current sensitivity. Confirm the waveform and protection requirements of the circuit.

03

Coordinate overcurrent protection

Select a compatible MCB or fuse and request the manufacturer’s short-circuit coordination data. The RCCB does not replace overcurrent protection.

04

Confirm the offered current

The reviewed current choices include 25, 40, 50, 63, 80, 100 A. Confirm the complete model code and rating for the quoted unit.

Before specifying JCRD4-125: Confirm the exact order code, current, residual-current type and sensitivity, plus upstream short-circuit coordination. The table includes 125 A but the feature text says up to 100 A; confirm any 125 A offer with a matching datasheet.

W9 그룹 소개

W9 Group RCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCRD4-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCRD4-125 RCCB Datasheet and Upstream Protection Information

Use W9 Group technical support and the product directory to specify JCRD4-125. Request a datasheet and wiring diagram matching the selected JCRD4-125 configuration.

구매자 FAQ

JCRD4-125 RCCB FAQs: 30mA Options and Overcurrent Coordination

Find answers about JCRD4-125 selection, configuration and ordering.

Is JCRD4-125 an RCCB or an RCBO?

It is listed as an RCCB: residual-current protection without integral overload and short-circuit protection. Use a coordinated MCB or fuse for those functions.

Which pole and supply arrangement is listed?

This model is listed as 4P. The voltage choices appear in the specifications; confirm the selected voltage and neutral connection diagram in the offered datasheet.

Which residual-current sensitivities are available?

W9 Group lists 30 mA, 100 mA and 300 mA options. Select the sensitivity for the required protection purpose and coordination.

How do I specify Type A or Type AC?

The source lists both options. State the connected equipment and required residual-current waveform response, and confirm the selected type in the quotation.

Does a 6kA figure mean the RCCB protects against overload?

No. A short-circuit figure does not establish integral overcurrent protection. Confirm the conditional short-circuit rating and required upstream protective device.

What installation details should be checked?

The source lists 35 mm DIN-rail mounting and IP20 protection. Confirm terminal sizes, busbar compatibility, connection instructions and enclosure requirements.

What is needed for a JCRD4-125 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JCRD4-125 RCCB Quotation

Tell W9 Group your pole count, current, residual-current type, sensitivity, supply voltage and upstream protection, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기