산업용 제품

홈제품산업용 제품MCCBMCCB M7 시리즈WLM7HUWLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 1
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 2
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 3
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 1
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 2
  • WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb Gallery image 3

WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb

Rated Current : 315A Number Of Poles : 3P Rated Working Voltage : 800V

MCCB Highlights

800V MCCBs for isolator application offer solution for switching various loads such as UPS,battery banks,etc.with many advantages.These MCCBs differ from regular MCCBs only in terms of absence of protection trip units.These MCCBs can be used for following applications for isolation purpose:
·For local isolation:such as very close to motor load
·Incoming of any sub-distribution
·As an isolator for bus coupler
·As an automatic switch
·For switching applications of motors with VFDs,soft starterslsolator application MCCBs are always backed up by short circuit protection device to protectthe downstream loads/installations against short circuit.Following advantages are offered byisolator MCCBs:
·Suitable for positive isolation
·Available with 3P and 4P versions
·Can be used with under voltage protection
·Remote tripping through shunt release
·Motor operated MCCBs
·Status Feedback possible

Main performance index of WLM7HU series circuit breaker

WLM7HU Moulded Case Circuit Breaker 315
Rated operating current In (A),40℃ 280-300-315
Rated insulation voltage Ui (V) 1150
Rated impulse withstand voltage (kV) 12
Rated operational voltage Ue(V),AC 50/60Hz 415/690/800/1000/1140v
Breaking capacity code – M H
Number of poles 3P – ■ ■
AC415V – – –
AC690V – – –
Rated ultimate
short-circuit breaking
capacity Icu(kA)
AC800V – 35 50
AC1000V – 15 20
AC1140V – 15 15
AC415V – – –
AC690V – – –
Rated service breaking
capacity Ics(kA)
AC800V – 35 50
AC1000V – 15 20
AC1140V – 15 15
Standard IEC/EN 60947-2
Utilization category A
Ambient temperature -40℃ ~+70 ℃
Safety of insulation ■
Arcing distance 0
Mechanical life
(CO recycle)
Maintenance free 20000
Electrical life
(CO recycle)
Maintenance free 1500
Release units
Distribution protection TM ■
Mounting and connection
Fixed Front connection ■
Rear connection ■
Plug-in Front connection ■
Rear connection ■
Draw-out Front connection –
Rear connection –
DIN rail Front connection –
Dimension
Dimension (mm)
W×H×D
Width 107
Height 200
Depth 109
Weight
Weight(kg)/Fixed 3P 3

Overall and installation dimensions of circuit breaker

WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb detail image 1WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb detail image 2