회로 보호 제품

  • AC 서지 보호 장치 JCSP-60 서지 보호 장치 30/60kA
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 2
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 3
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 4
  • AC 서지 보호 장치 JCSP-60 서지 보호 장치 30/60kA
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 2
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 3
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 4

JCSP-60 Ac Surge Protection Device

W9 Group lists JCSP-60 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 30 kA, maximum discharge current Imax of 60 kA and maximum continuous AC operating voltage Uc of 275 V. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JCSP-60 Type 2 AC Surge Protection Device Specifications

W9 Group lists JCSP-60 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 30 kA, maximum discharge current Imax of 60 kA and maximum continuous AC operating voltage Uc of 275 V.

Technology MOV, MOV+GSG are available
형태 Type2
Network 230 V single-phase
400 V 3-phase
Max. AC operating voltage   Uc 275V
Temporary Over Voltage (TOV) Charasteristics – 5 sec.   UT 335 Vac withstand
Temporary Over Voltage (TOV) Charasteristics – 120 mn   UT 440 Vac disconnection
Nominal discharge current    In 30 kA
Max. discharge current  Imax 60kA
Withstand on Combination waveform IEC 61643-11  Uoc 6kV
Protection level  Up 1.8kV
Protection level N/PE at 5 kA 0.7 kV
Residual voltage L/PE at 5 kA 0.7 kV
Admissible short-circuit current 25kA
Connection to Network By screw terminals: 2.5-25 mm²
장착 Symmetrical rail 35 mm (DIN 60715)
Operating temperature -40 / +85°C
Protection rating IP20
Failsafe mode  Disconnection from AC network
Disconnection indicator 1 mechanical indicator by pole – Red/Green
Fuses 50 A mini. – 125 A max. – Fuses Type gG
Standards compliance IEC 61643-11 / EN 61643-11

선정 가이드

Selecting a 275V AC SPD with 30kA In and 60kA Imax

Specify the supply voltage, earthing system, pole arrangement, SPD classification and backup protection when you request a JCSP-60 quotation from W9 Group.

01

Match the supply network

For JCSP-60, specify single-phase or three-phase supply and the earthing arrangement so the connection scheme can be confirmed.

02

Check surge ratings

Compare Uc, Up and discharge-current ratings in the matching datasheet; confirm classification and any impulse-current rating required by the project.

03

Check protective coordination

Ask for the required backup protection, conductor sizing and installation connection drawing for the selected SPD.

04

Plan inspection and replacement

Request status-indicator instructions, replacement-module compatibility and any remote indication option for the offered version.

Before ordering JCSP-60: confirm supply voltage, earthing system, pole arrangement, SPD classification and backup protection, the matching datasheet and the installation drawing.

W9 그룹 소개

W9 Group Type 2 AC SPD Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCSP-60 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCSP-60 Type 2 AC SPD Technical Document Requests

Use W9 Group technical support and the product directory to specify JCSP-60. Request the matching datasheet before ordering.

구매자 FAQ

Type 2 AC SPD FAQs: Earthing and Backup Protection

Find answers about JCSP-60 selection, configuration and ordering.

Where is JCSP-60 intended to be used?

The supplier table identifies AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device.

What do In and Imax mean on this page?

They are the nominal and maximum discharge-current labels in the supplier table. Use the associated test data when comparing SPDs; confirm the required project classification separately.

How should I specify the version?

State JCSP-60, supply voltage, earthing arrangement, pole count and required SPD classification; request the corresponding datasheet.

What is needed for a JCSP-60 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

What is JCSP-60 used for?

The supplier tables identify this model family for AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device; the page does not certify a universal installation.

How should I compare In and Imax when selecting an AC SPD?

Use the supplier table’s nominal and maximum discharge-current labels together with the project classification and test data. Confirm the required SPD class and wiring before ordering.

제품 문의

Request a JCSP-60 Type 2 AC SPD Quotation

Tell W9 Group your supply voltage, earthing system, pole arrangement, SPD classification and backup protection, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기