Productos de protección de circuitos

  • Dispositivo de protección contra sobretensiones AC JCSP-60 Dispositivo de protección contra sobretensiones 30/60kA Imagen de la galería 1
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 2
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 3
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 4
  • Dispositivo de protección contra sobretensiones AC JCSP-60 Dispositivo de protección contra sobretensiones 30/60kA Imagen de la galería 1
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 2
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 3
  • AC Surge Protective Device JCSP-60 Surge protection Device 30/60kA Gallery image 4

JCSP-60 Ac Surge Protection Device

W9 Group lists JCSP-60 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 30 kA, maximum discharge current Imax of 60 kA and maximum continuous AC operating voltage Uc of 275 V. Request the selected configuration and matching technical documents from W9 Group.

DATOS TÉCNICOS

JCSP-60 Type 2 AC Surge Protection Device Specifications

W9 Group lists JCSP-60 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 30 kA, maximum discharge current Imax of 60 kA and maximum continuous AC operating voltage Uc of 275 V.

JCSP-60 product specifications
Modelo JCSP-60
Network 230 V single-phase / 400 V three-phase; confirm connection
SPD classification Type 2 in the technical table
Technology options MOV / MOV+GSG; confirm version
Maximum continuous operating voltage Uc 275 V AC
Nominal discharge current In 30 kA
Maximum discharge current Imax 60 kA
Protection level Up 1.8 kV
Conexión terminal Screw terminals, 2.5–25 mm²
Instalación 35 mm DIN rail
Protection rating IP20

Guía de selección

Selecting a 275V AC SPD with 30kA In and 60kA Imax

Specify the supply voltage, earthing system, pole arrangement, SPD classification and backup protection when you request a JCSP-60 quotation from W9 Group.

01

Match the supply network

For JCSP-60, specify single-phase or three-phase supply and the earthing arrangement so the connection scheme can be confirmed.

02

Check surge ratings

Compare Uc, Up and discharge-current ratings in the matching datasheet; confirm classification and any impulse-current rating required by the project.

03

Check protective coordination

Ask for the required backup protection, conductor sizing and installation connection drawing for the selected SPD.

04

Plan inspection and replacement

Request status-indicator instructions, replacement-module compatibility and any remote indication option for the offered version.

Before ordering JCSP-60: confirm supply voltage, earthing system, pole arrangement, SPD classification and backup protection, the matching datasheet and the installation drawing.

QUÉ ES W9 GROUP

W9 Group Type 2 AC SPD Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCSP-60 enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

JCSP-60 Type 2 AC SPD Technical Document Requests

Use W9 Group technical support and the product directory to specify JCSP-60. Request the matching datasheet before ordering.

Preguntas frecuentes del comprador

Type 2 AC SPD FAQs: Earthing and Backup Protection

Find answers about JCSP-60 selection, configuration and ordering.

Where is JCSP-60 intended to be used?

The supplier table identifies AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device.

What do In and Imax mean on this page?

They are the nominal and maximum discharge-current labels in the supplier table. Use the associated test data when comparing SPDs; confirm the required project classification separately.

How should I specify the version?

State JCSP-60, supply voltage, earthing arrangement, pole count and required SPD classification; request the corresponding datasheet.

What is needed for a JCSP-60 quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

What is JCSP-60 used for?

The supplier tables identify this model family for AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device; the page does not certify a universal installation.

How should I compare In and Imax when selecting an AC SPD?

Use the supplier table’s nominal and maximum discharge-current labels together with the project classification and test data. Confirm the required SPD class and wiring before ordering.

Solicitud de producto

Request a JCSP-60 Type 2 AC SPD Quotation

Tell W9 Group your supply voltage, earthing system, pole arrangement, SPD classification and backup protection, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group