サーキット保護製品

ホーム製品サーキット保護製品MCBアクセサリーJCMX シャント トリップ リリース
  • MCCB アクセサリー JCMX シュントトリップリリース MX ギャラリー画像1
  • MCCB Accessories JCMX Shunt trip release MX Gallery image 2
  • MCCB Accessories JCMX Shunt trip release MX Gallery image 3
  • MCCB アクセサリー JCMX シュントトリップリリース MX ギャラリー画像1
  • MCCB Accessories JCMX Shunt trip release MX Gallery image 2
  • MCCB Accessories JCMX Shunt trip release MX Gallery image 3

JCMX シャント トリップ リリース

The JCMX shunt trip release is an externally energized accessory for opening a compatible breaker. W9 Group’s body text describes fitting it to the left side of compatible MCB / RCBO devices. Confirm the host breaker and coil voltage; the release does not provide remote closing or independent circuit protection. Request the selected configuration and matching technical documents from W9 Group.

技術データ

JCMX Shunt Trip Release Specifications and Coil Options

The JCMX shunt trip release is an externally energized accessory for opening a compatible breaker. W9 Group’s body text describes fitting it to the left side of compatible MCB / RCBO devices. Confirm the host breaker and coil voltage; the release does not provide remote closing or independent circuit protection.

スタンダード IEC61009-1 ,  EN61009-1
電気機能 Rated voltage Us (V) AC230, AC400 50/60Hz
DC24/DC48
Rated impulse withstand voltage(1.2/50) Uimp (V) 4000
ポーランド人 1 Pole (18mm Width)
絶縁電圧 Ui(V) 500
Dielectric TEST voltage at ind.Freq.for 1 min (kV) 2
汚染度 2
機械的特徴 電気寿命 4000
機械的寿命 4000
保護レベル IP20
サーマルエレメントの設定時の基準温度(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70
インストール ターミナル接続タイプ Cable
ケーブル用の端末サイズの上部/下部 2.5mm2  / 18-14 AWG
締めトルク 2 N*m  /  18 In-Ibs.
取り付け On DIN rail EN 60715 (35mm) by means of fast clip device

選定ガイド

Selecting an MCB Shunt Trip Accessory for Remote Opening

Specify the host breaker model, coil voltage/type, trip command and required indication accessories when requesting a JCMX quotation from W9 Group.

01

ホストブレーカを特定する

Provide the exact MCB or RCBO model. Confirm mechanical coupling and accessory compatibility before ordering.

02

Match the release coil

Choose the coil for the control voltage and AC / DC supply. Confirm the order code and terminal diagram.

03

Design the trip command

Confirm the permitted energization duration and the required control-circuit arrangement; source duty descriptions conflict.

04

Plan indication separately

If breaker position or fault-trip feedback is needed, confirm a separate compatible contact accessory.

Before specifying JCMX: Confirm the exact host, coil code, terminal diagram and energization duty. The source title and body describe different host categories.

W9 GROUPについて

W9 Group Breaker Accessory Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMX enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JCMX Shunt Trip Wiring and Breaker Compatibility Information

Use W9 Group technical support and the product directory to specify JCMX. Request a datasheet and wiring diagram matching the selected JCMX configuration.

購入者のよくある質問

JCMX Shunt Trip Release FAQs: Coil Duty and Remote Tripping

Find answers about JCMX selection, configuration and ordering.

What does a JCMX shunt trip release do?

Applying the specified control voltage to the release trips a compatible host breaker open. Confirm the host breaker and wiring diagram.

Can JCMX remotely close the breaker?

No remote-closing function is established. It is described as a shunt trip release for opening; confirm a separate operating mechanism if closing is required.

Which coil voltages are listed?

The AC and DC coil-voltage choices appear in the specifications. Confirm the particular coil code and supply frequency rather than assuming one unit accepts all listed supplies.

Will JCMX fit any MCCB, MCB or RCBO?

No. The title mentions MCCB, while the body describes MCB / RCBO mounting. Confirm exact compatible host codes with W9 Group.

Can the coil remain energized continuously?

The page contains conflicting duty descriptions. Confirm permitted pulse duration, continuous-duty capability and required control wiring from the matching instructions.

Does the release provide trip feedback or overload protection?

No auxiliary feedback is listed, and the accessory is not an independent overload or short-circuit protective device. Confirm separate indication and the host breaker’s protection functions.

What is needed for a JCMX quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a JCMX Shunt Trip Release Quotation

Tell W9 Group your host breaker model, coil voltage/type, trip command and required indication accessories, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ