サーキット保護製品

ホーム製品サーキット保護製品MCBアクセサリーJCMX1-125 シャントトリップ脱扣器
  • MCB アクセサリー JCMX1-125 シュント トリップ リリース MX ギャラリー画像 1
  • MCB Accessories JCMX1-125 Shunt trip release MX Gallery image 2
  • MCB Accessories JCMX1-125 Shunt trip release MX Gallery image 3
  • MCB アクセサリー JCMX1-125 シュント トリップ リリース MX ギャラリー画像 1
  • MCB Accessories JCMX1-125 Shunt trip release MX Gallery image 2
  • MCB Accessories JCMX1-125 Shunt trip release MX Gallery image 3

JCMX1-125 シャントトリップリリースの解除

The JCMX1-125 shunt trip release remotely opens a compatible MCB or RCBO when a voltage is applied. W9 Group describes left-side mounting with a special pin and a shunt-trip function without auxiliary feedback. Specify the host breaker and coil supply before using it in a remote-trip control circuit. Request the selected configuration and matching technical documents from W9 Group.

技術データ

JCMX1-125 Shunt Trip Release for Remote MCB and RCBO Opening

The JCMX1-125 shunt trip release remotely opens a compatible MCB or RCBO when a voltage is applied. W9 Group describes left-side mounting with a special pin and a shunt-trip function without auxiliary feedback. Specify the host breaker and coil supply before using it in a remote-trip control circuit.

JCMX1-125 product specifications
モデル JCMX1-125
Accessory designation MX shunt trip release
Operating function Remote opening when voltage is applied
Host class listed MCB / RCBO; confirm compatible models
取り付け Left side using the specified special pin
Auxiliary feedback Not included in the stated shunt-trip function
Coil supply and duty Confirm rated voltage, frequency and permitted command duration

選定ガイド

Selecting a JCMX1-125 MX Shunt Trip by Coil Voltage and Breaker Compatibility

Specify the MCB or RCBO model, coil voltage, supply type, trip-command duty and feedback requirements when requesting a JCMX1-125 quotation from W9 Group.

01

Match the breaker interface

Confirm the compatible MCB or RCBO model, mounting pin and allowed accessory combinations. The same product category does not establish a mechanical fit.

02

Choose the coil supply

Provide the available control voltage and AC or DC supply. Request the matching coil code, voltage tolerance and consumption.

03

Define the trip command

Confirm the permitted energization time, control wiring and reset sequence. Check how the command circuit is released after tripping.

04

Provide feedback separately

This release has no stated auxiliary feedback. Request a compatible position or trip-indication contact if the control system needs confirmation of the breaker state.

Before specifying JCMX1-125: Confirm the exact host, coil supply and command duty. A trip command does not provide a returned status signal or remote-closing function.

W9 GROUPについて

W9 Group JCMX1-125 Shunt Trip Release Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCMX1-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JCMX1-125 Shunt Trip Wiring, Command Duty and Reset Documents

Use technical support and related products to specify JCMX1-125. Request a datasheet and wiring diagram matching the selected JCMX1-125 configuration.

購入者のよくある質問

JCMX1-125 Shunt Trip FAQs: Remote Opening and Auxiliary Feedback

Find answers about JCMX1-125 selection, configuration and ordering.

How does the JCMX1-125 shunt trip release operate?

Applying the specified coil voltage commands a compatible MCB or RCBO to open. Confirm the exact coil supply and host arrangement from the matching wiring diagram.

Does JCMX1-125 include auxiliary feedback?

The native summary explicitly states shunt-trip operation only, without auxiliary feedback. Confirm a separate compatible contact if the controller needs a breaker-state signal.

Where is the release mounted?

The source specifies left-side mounting to the MCB or RCBO using a special pin. Confirm the exact breaker model and the approved accessory assembly.

Which coil voltage and command duration should I use?

These values are not established in the available target data. Request the coil code, rated supply, operating tolerance and maximum permitted energization time.

Can the shunt release close the breaker remotely?

This listing describes remote opening. Remote closing requires a separately specified operating mechanism; it is not a stated function of this release.

Does a shunt release replace residual-current protection?

A commanded trip accessory does not by itself sense earth leakage. Confirm the separate protective device and detection arrangement required for the circuit.

What is needed for a JCMX1-125 quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a JCMX1-125 Shunt Trip Release Quotation

Tell W9 Group your MCB or RCBO model, coil voltage, supply type, trip-command duty and feedback requirements, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ