HomeProductsPhotovoltaicSolar 800VAC ACBWEW3-4000 air circuit breaker
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 1
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 1
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4

WEW3-4000 air circuit breaker

The WEW3-4000 air circuit breaker is listed by W9 Group with a 4000 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

WEW3-4000 3 Pole and 4 Pole Air Circuit Breaker Specifications

The WEW3-4000 air circuit breaker is listed by W9 Group with a 4000 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code.

WEW3 Air Circuit Breaker 4000
Rated operating current In (A),40℃ 2000-2500-2900-3200-3600-3900-4000
Rated insulation voltage Ui (V) 1000
Rated impulse withstand voltage (kV) 12
Rated operational voltage Ue(V),AC 50/60Hz 400V/690V
Use category B
Rated operational voltage Ue(V),AC 50/60Hz 100%In
Breaking capacity code M H
Number of poles 3P ■ ■
4P ■ ■
Rated ultimate
short-circuit breaking
capacity Icu (kA)
AC380V/400V/415V 100 138
AC690V 65 105
AC800V/1140V 80 138
Rated service breaking
capacity Ics (kA)
AC380V/400V/415V 65 105
AC690V 80 138
AC800V/1140V 65 105
Rated short-time withstand 
current Icw (kA/1s)
AC380V/400V/415V 80 138
AC690V 65 105
AC800V/1140V – –
Mechanical life
(CO recycle)
Maintenance 20000
Electrical life
(CO recycle)
AC415V,In 6000
AC690V,In 2000
Standard configuration Fixed Drawetry-pe
The body of the circuit breaker ■ ■
Drawer base ■ ■
Intelligent controller ■ ■
Upper and lower horizontal connecting wires ■ ■
Indicating contact of opening/closing ■ ■
Indicating contact of fault tripping ■ ■
Auxiliary contact 4NO+4NC ■ ■
Electric motor operating mechanism ■ ■
Shunt releas ■ ■
Optional accessories
Phase partition □ □
Instantaneous undervoltage release □ □
Time-delay undervoltage release □ □
Opening and closing button lock □ □
Lock for the drawer base □ □
Lock for the separation position of the drawer seat □ □
Key lock □ □
Door interlock □ □
Auxiliary contact 6NO+6NC □ □
Electric indications of three positions on the drawer base □ □
Steel cable interlock □ □
Locking interlock □ □
Dual power controller □ □
External neutral line transformer □ □
Zero-sequence transformer □ □
Ground current transformer and its accessories □ □
Dimension
Dimension (mm)
W×H×D
Width (3P/4P) 66/105 66/105
Height 57/60 60/62
Depth 60/62 57/61
Weight
Weight(kg)/Fixed 3P 83/83
4P 110.2/125.2
Weight(kg)/Drawer 3P 122/150
4P 155/175

SELECTION GUIDE

How to Select a 4000A Fixed or Withdrawable Air Circuit Breaker

Specify the ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements when requesting a WEW3-4000 quotation from W9 Group.

01

Define the current and frame

State WEW3-4000, the ordered current and continuous load. Confirm the selected controller and any derating conditions.

02

Match the application voltage

Provide system voltage and prospective fault current. Request a matched rating table rather than relying on a generic solar application title.

03

Choose fixed or withdrawable

Confirm the construction, base, interlocks, terminal arrangement and maintenance access on the installation drawing.

04

Specify the control package

List required trip functions, operating supply, auxiliary feedback and communication needs. Confirm each item in the supplied bill of materials.

Before specifying WEW3-4000: Confirm the complete model, voltage, controller and fault-duty documentation. Series solar wording does not establish extended-voltage or outdoor suitability for the supplied breaker.

ABOUT W9 GROUP

W9 Group 4000A Air Circuit Breaker Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WEW3-4000 enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

WEW3-4000 ACB Wiring, Icu, Ics and Icw Document Requests

Use technical support and related products to specify WEW3-4000. Request a datasheet and wiring diagram matching the selected WEW3-4000 configuration.

BUYER FAQ

WEW3-4000 Air Circuit Breaker FAQs: Fault Ratings and Trip Controllers

Find answers about WEW3-4000 selection, configuration and ordering.

Which current choices are listed for WEW3-4000?

The target table lists 2000, 2500, 2900, 3200, 3600, 3900, 4000 A. Confirm the ordered current, controller range and any enclosure or temperature derating.

Does the listing establish every voltage mentioned in the old title?

Use a matched rating document for the offered device. The summary, title and some table entries differ; no extended-voltage suitability is promised from the title alone.

How do fixed and withdrawable versions differ for ordering?

State the required construction and confirm the supplied base, position indication, interlocks, terminals and installation dimensions for that version.

Are Icu, Ics and Icw interchangeable ratings?

Request all required ratings separately at the project voltage. Confirm the short-time withstand duration and the controller settings used in the coordination study.

Does every controller include ground-fault protection or communication?

A series configuration list does not establish every controller function. Confirm the exact controller code, sensing arrangement, protection functions and communication interface.

Can the breaker be installed outdoors without an enclosure?

The available listing does not establish a complete outdoor enclosure specification. Confirm the switchboard protection, environmental conditions and installation requirements; generic waterproof wording is not a device rating.

What is needed for a WEW3-4000 quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a WEW3-4000 Air Circuit Breaker Quotation

Tell W9 Group your ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements, quantity and destination market so the selected configuration can be identified.

Contact W9 Group