  • Disjuntor de circuito de aire WEW3-4000 tipo acb retráctil tipo acb fijo 1000VAC/1500VAC 4000A 3p acb 4p acb Galería de imágenes 1
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4
  • Disjuntor de circuito de aire WEW3-4000 tipo acb retráctil tipo acb fijo 1000VAC/1500VAC 4000A 3p acb 4p acb Galería de imágenes 1
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4

Disjuntor de circuito de aire WEW3-4000

The WEW3-4000 air circuit breaker is listed by W9 Group with a 4000 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code. Request the selected configuration and matching technical documents from W9 Group.

DATOS TÉCNICOS

WEW3-4000 3 Pole and 4 Pole Air Circuit Breaker Specifications

El disyuntor de circuito de aire WEW3-4000 está catalogado por W9 Group con una clasificación de 4000 A, opciones de 3P/4P y configuraciones fijas o retráctiles. Seleccione el voltaje y el controlador solicitados, luego obtenga las clasificaciones de fallas específicas de la tensión y los datos de instalación para el código de capacidad exacto.

WEW3 Air Circuit Breaker 4000
Corriente de operación nominal en (A), 40 °C 2000-2500-2900-3200-3600-3900-4000
Tensión de aislamiento nominal Ui (V) 1000
Tensión de resistencia a la impulsión nominal (kV) 12
Tensión operativa nominal Ue(V), CA 50/60Hz 400V/690V
Utiliza la categoría B
Tensión operativa nominal Ue(V), CA 50/60Hz 100%In
Código de capacidad de ruptura M H
Número de postes 3P ■ ■
4P ■ ■
Calificado como el mejor
Desconexión por cortocircuito
Capacidad de la unidad de control (kA)
AC380V/400V/415V 100 138
AC690V 65 105
AC800V/1140V 80 138
Servicio de calidad quebrado
Capacidad Ics (kA)
AC380V/400V/415V 65 105
AC690V 80 138
AC800V/1140V 65 105
Resistencia a corto tiempo de carga 
Corriente actual Icw (kA/1s)
AC380V/400V/415V 80 138
AC690V 65 105
AC800V/1140V – –
Vida mecánica
(Reciclaje de CO)
Mantenimiento 20000
Vida eléctrica
(Reciclaje de CO)
AC415V,En 6000
AC690V,En 2000
Configuración estándar Corregido Drawetry-pe
El cuerpo del disyuntor ■ ■
Base de la cajuela ■ ■
Controllor inteligente ■ ■
Cables horizontales de conexión superior e inferior ■ ■
Indica el contacto entre la apertura y la cierre ■ ■
Indica el contacto con el fallo de disparo ■ ■
Conector auxiliar 4NO+4NC ■ ■
Mecanismo de funcionamiento del motor eléctrico ■ ■
Desconexión de shunt ■ ■
Accesorios opcionales
Partición de fase □ □
Desconexión instantánea de bajo voltaje □ □
Desconexión temporal por sobrevoltaje □ □
Bloqueo de la apertura y la sujeción de la puerta □ □
Bloqueo para la base del cajón □ □
Bloqueo para la posición de separación del asiento del cajón □ □
Bloqueo de llave □ □
Bloqueo de la puerta □ □
Conector auxiliar 6NO+6NC □ □
Indicaciones eléctricas de tres posiciones en la base del cajón □ □
Interbloqueo de cable de acero □ □
Bloqueo de seguridad □ □
Controlador de energía dual □ □
Transformador de línea neutra externo □ □
Transformador de secuencia cero □ □
Transformador de corriente de tierra y sus accesorios □ □
Dimension
Dimensiones (mm)
W×H×D
Ancho (3P/4P) 66/105 66/105
Altura 57/60 60/62
Profundidad 60/62 57/61
Peso
Peso (kg)/Fijo 3P 83/83
4P 110.2/125.2
Peso (kg)/Caja 3P 122/150
4P 155/175

Guía de selección

How to Select a 4000A Fixed or Withdrawable Air Circuit Breaker

Specify the ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements when requesting a WEW3-4000 quotation from W9 Group.

01

Define the current and frame

State WEW3-4000, the ordered current and continuous load. Confirm the selected controller and any derating conditions.

02

Match the application voltage

Provide system voltage and prospective fault current. Request a matched rating table rather than relying on a generic solar application title.

03

Choose fixed or withdrawable

Confirm the construction, base, interlocks, terminal arrangement and maintenance access on the installation drawing.

04

Specify the control package

List required trip functions, operating supply, auxiliary feedback and communication needs. Confirm each item in the supplied bill of materials.

Before specifying WEW3-4000: Confirm the complete model, voltage, controller and fault-duty documentation. Series solar wording does not establish extended-voltage or outdoor suitability for the supplied breaker.

QUÉ ES W9 GROUP

W9 Group 4000A Air Circuit Breaker Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WEW3-4000 enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

WEW3-4000 ACB Wiring, Icu, Ics and Icw Document Requests

Use technical support and related products to specify WEW3-4000. Request a datasheet and wiring diagram matching the selected WEW3-4000 configuration.

Preguntas frecuentes del comprador

WEW3-4000 Air Circuit Breaker FAQs: Fault Ratings and Trip Controllers

Find answers about WEW3-4000 selection, configuration and ordering.

Which current choices are listed for WEW3-4000?

The target table lists 2000, 2500, 2900, 3200, 3600, 3900, 4000 A. Confirm the ordered current, controller range and any enclosure or temperature derating.

Does the listing establish every voltage mentioned in the old title?

Use a matched rating document for the offered device. The summary, title and some table entries differ; no extended-voltage suitability is promised from the title alone.

How do fixed and withdrawable versions differ for ordering?

State the required construction and confirm the supplied base, position indication, interlocks, terminals and installation dimensions for that version.

¿Son las calificaciones Icu, Ics e Icw intercambiables?

Request all required ratings separately at the project voltage. Confirm the short-time withstand duration and the controller settings used in the coordination study.

Does every controller include ground-fault protection or communication?

A series configuration list does not establish every controller function. Confirm the exact controller code, sensing arrangement, protection functions and communication interface.

Can the breaker be installed outdoors without an enclosure?

The available listing does not establish a complete outdoor enclosure specification. Confirm the switchboard protection, environmental conditions and installation requirements; generic waterproof wording is not a device rating.

What is needed for a WEW3-4000 quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

Solicitud de producto

Request a WEW3-4000 Air Circuit Breaker Quotation

Tell W9 Group your ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group