회로 보호 제품

  • 미니트랜스커 JCB3-80M 6kA 갤러리 이미지 1
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 12
  • 미니트랜스커 JCB3-80M 6kA 갤러리 이미지 1
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 12

JCB3-80M MCB

The JCB3-80M MCB is a miniature circuit breaker for overload and short-circuit protection. W9 Group lists 1–80 A and a 6 kA breaking rating, with 1P / 2P / 3P / 4P configurations. Choose the current, pole count and trip curve for the circuit and board arrangement. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JCB3-80M 6kA Miniature Circuit Breaker Specifications

The JCB3-80M MCB is a miniature circuit breaker for overload and short-circuit protection. W9 Group lists 1–80 A and a 6 kA breaking rating, with 1P / 2P / 3P / 4P configurations. Choose the current, pole count and trip curve for the circuit and board arrangement.

표준 IEC/ EN 60898- 1  IEC/ EN 60947- 2
전기 기능 Rated current In ( A) 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
폴란드인 1P, 1P+ N, 2P, 3P, 3P+ N, 4P 1P, 2P, 3P, 4P
Rated voltage Ue( V) 230/ 400~ 240/ 415
Insulation voltage Ui ( V) 500
정격 주파수 50/ 60Hz
최대 절단 용량 6kA
Energy  limiting class 3
Rated impulse withstand voltage( 1. 2/ 50) Uimp ( V) 4000
Dielectric test voltage at ind. Freq. for 1 min ( kV) 2
오염 정도 2
Power  loss  per pole Rated  current  ( A)
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
Thermo- magnetic release characteristic B, C, D 8- 12In, 9. 6- 14. 4In
Mechanicalfe atures 전기 수명 4,000
기계적 수명 20,000
접촉 위치 표시기 네
보호 수준 IP 20
열체 열 설정 기준 온도(℃) 30
Ambient temperature ( with daily average ≤35℃) – 5…+40 ℃
Storage temperation (℃) -25…+ 70 ℃
설치 터미널 연결 유형 Cable/ U- type busbar/ Pin- type busbar
Terminal size top/ bottom for cable 25mm2 / 18- 4 AWG
Terminal size top/ bottom for busbar 10mm2 / 18- 8 AWG
강력한 토크 2. 5 N* m / 22 In- Ibs.
장착 On DIN rail EN 60715 ( 35mm) by means of fast clip device
연결 From  top  and bottom
Combination withaccessori es 보조 연락처 네
스촇 방출 네
전압 감소 시 네
알람 접촉 네

선정 가이드

How to Select a 1 Pole to 4 Pole MCB

Specify the rated current, pole count, trip curve, operating voltage and board connection details when requesting a JCB3-80M quotation from W9 Group.

01

Match current to the circuit

The catalog covers 1–80 A. Confirm the required current step and coordinate it with the circuit conductors and load.

02

Choose the trip curve

The reviewed matching features list B / C / D. Request the selected time-current curve for starting-current and coordination checks.

03

Specify poles and supply

State the supply voltage and required 1P / 2P / 3P / 4P arrangement. Confirm the wiring diagram and terminal allocation.

04

Check the board space

Request dimensions and busbar details for the selected pole version before finalizing the board.

Before specifying JCB3-80M: Confirm the ordered current, pole configuration, operating voltage and trip curve. Use the matching model datasheet for installation and fault-duty checks.

W9 그룹 소개

W9 Group MCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB3-80M enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCB3-80M MCB Datasheet and Trip Curve Information

Use W9 Group technical support and the product directory to specify JCB3-80M. Request a datasheet and wiring diagram matching the selected JCB3-80M configuration.

구매자 FAQ

JCB3-80M MCB FAQs: Pole Options and Short-Circuit Rating

Find answers about JCB3-80M selection, configuration and ordering.

What does JCB3-80M protect against?

The product is listed for overload and short-circuit protection. Residual-current protection requires a suitable additional device or an RCBO configuration.

Which currents are listed for JCB3-80M?

The target-model summary lists a 1–80 A range. Confirm the individual current rating and complete order code.

Which pole configurations are offered?

This page lists 1P / 2P / 3P / 4P. Confirm the wiring and neutral arrangement in the matching product drawing.

How do I specify the trip curve?

The matching features list B / C / D. Select using the load starting current and protective coordination, and request the corresponding curve.

Is the listed 6kA rating suitable for every board?

The breaking rating must meet the prospective short-circuit current at the installation point. Confirm the applicable voltage and rating on the supplied datasheet.

How is this MCB installed?

The source lists 35 mm DIN-rail mounting. Confirm the terminal capacity, busbar type, dimensions and tightening instructions for the ordered version.

What is needed for a JCB3-80M quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JCB3-80M MCB Quotation

Tell W9 Group your rated current, pole count, trip curve, operating voltage and board connection details, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기