JCB3-80M MCB
اطلاعات فنی
JCB3-80M 6kA Miniature Circuit Breaker Specifications
The JCB3-80M MCB is a miniature circuit breaker for overload and short-circuit protection. W9 Group lists 1–80 A and a 6 kA breaking rating, with 1P / 2P / 3P / 4P configurations. Choose the current, pole count and trip curve for the circuit and board arrangement.
| استاندارد | IEC/ EN 60898- 1 | IEC/ EN 60947- 2 | ||
| ویژگیهای الکتریکی | Rated current In ( A) | 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80 | ||
| پوشندگان لهستانی | 1P, 1P+ N, 2P, 3P, 3P+ N, 4P | 1P, 2P, 3P, 4P | ||
| Rated voltage Ue( V) | 230/ 400~ 240/ 415 | |||
| Insulation voltage Ui ( V) | 500 | |||
| فراوانی رتبهبندی شده | 50/ 60Hz | |||
| قدرت شکسته شدن بر اساس رتبه بندی | 6kA | |||
| Energy limiting class | 3 | |||
| Rated impulse withstand voltage( 1. 2/ 50) Uimp ( V) | 4000 | |||
| Dielectric test voltage at ind. Freq. for 1 min ( kV) | 2 | |||
| سطح آلودگی | 2 | |||
| Power loss per pole | Rated current ( A) | |||
| 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80 | ||||
| Thermo- magnetic release characteristic | B, C, D | 8- 12In, 9. 6- 14. 4In | ||
| Mechanicalfe atures | زندگی الکتریکی | 4,000 | ||
| زمان کارکرد مکانیکی | 20,000 | |||
| نمایشگر موقعیت تماس | بله | |||
| سطح حفاظت | IP 20 | |||
| دمای مرجع برای تنظیم عنصر حرارتی (درجه سانتیگراد) | 30 | |||
| Ambient temperature ( with daily average ≤35℃) | – 5…+40 ℃ | |||
| Storage temperation (℃) | -25…+ 70 ℃ | |||
| ارائه نصب | نوع اتصال ترمینال | Cable/ U- type busbar/ Pin- type busbar | ||
| Terminal size top/ bottom for cable | 25mm2 / 18- 4 AWG | |||
| Terminal size top/ bottom for busbar | 10mm2 / 18- 8 AWG | |||
| تنگ کردن گشتاور | 2. 5 N* m / 22 In- Ibs. | |||
| قرارگیری | On DIN rail EN 60715 ( 35mm) by means of fast clip device | |||
| اتصال | From top and bottom | |||
| Combination withaccessori es | تماس اضافی | بله | ||
| سوزش شنت | بله | |||
| در شرایط کاهش ولتاژ | بله | |||
| رابط هشدار | بله | |||
راهنمای انتخاب
How to Select a 1 Pole to 4 Pole MCB
Specify the rated current, pole count, trip curve, operating voltage and board connection details when requesting a JCB3-80M quotation from W9 Group.
Match current to the circuit
The catalog covers 1–80 A. Confirm the required current step and coordinate it with the circuit conductors and load.
Choose the trip curve
The reviewed matching features list B / C / D. Request the selected time-current curve for starting-current and coordination checks.
Specify poles and supply
State the supply voltage and required 1P / 2P / 3P / 4P arrangement. Confirm the wiring diagram and terminal allocation.
Check the board space
Request dimensions and busbar details for the selected pole version before finalizing the board.
درباره W9 Group
W9 Group MCB Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB3-80M enquiry, contact W9 Group about configuration and matching product documents.

منابع مرتبط
JCB3-80M MCB Datasheet and Trip Curve Information
Use W9 Group technical support and the product directory to specify JCB3-80M. Request a datasheet and wiring diagram matching the selected JCB3-80M configuration.
دسته بندی محصولاتمحصولات گروه W9 را بررسی کنیدمدلهای W9 Group را مرور کنید و مشخصات محصول انتخابشده را درخواست کنید.
اسنادمرکز دانلود W9 GroupRequest the current document for your quoted JCB3-80M variant
سوالات متداول خریداران
JCB3-80M MCB FAQs: Pole Options and Short-Circuit Rating
Find answers about JCB3-80M selection, configuration and ordering.
What does JCB3-80M protect against?
The product is listed for overload and short-circuit protection. Residual-current protection requires a suitable additional device or an RCBO configuration.
Which currents are listed for JCB3-80M?
The target-model summary lists a 1–80 A range. Confirm the individual current rating and complete order code.
Which pole configurations are offered?
This page lists 1P / 2P / 3P / 4P. Confirm the wiring and neutral arrangement in the matching product drawing.
How do I specify the trip curve?
The matching features list B / C / D. Select using the load starting current and protective coordination, and request the corresponding curve.
Is the listed 6kA rating suitable for every board?
The breaking rating must meet the prospective short-circuit current at the installation point. Confirm the applicable voltage and rating on the supplied datasheet.
How is this MCB installed?
The source lists 35 mm DIN-rail mounting. Confirm the terminal capacity, busbar type, dimensions and tightening instructions for the ordered version.
What is needed for a JCB3-80M quotation?
اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونهها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.
سؤال و جواب درباره محصول
Request a JCB3-80M MCB Quotation
Tell W9 Group your rated current, pole count, trip curve, operating voltage and board connection details, quantity and destination market so the selected configuration can be identified.