Circuit Protection Products

  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3

JCB2LE-EV 2 pole RCBO

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval. Request the selected configuration and matching technical documents from W9 Group.

  • Live and neutral open together
  • Electronic leakage detection
  • Overload and short-circuit protection

How the JCB2LE-EV 1P+N RCBO switches live and neutral

When the JCB2LE-EV trips, it opens both the live and neutral contacts of the outgoing circuit. This switched-neutral arrangement explains the 2 pole and 1P+N descriptions used for the same device. Its electronic protection covers earth leakage, overload and short circuits in consumer units and distribution boards.

JCB2LE-EV product view 1JCB2LE-EV product view 2JCB2LE-EV product view 3

TECHNICAL DATA

JCB2LE-EV 2 pole RCBO specifications

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval.

JCB2LE-EV product specifications
Model JCB2LE-EV
Protection Residual current, overload and short circuit
Current options 32A / 40A
Residual-current response Type A
Sensitivity 30mA
Listed breaking capacity 10kA
Trip curves B / C
Poles 2 pole; neutral switched

SELECTION GUIDE

JCB2LE-EV EV charging RCBO selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCB2LE-EV quotation from W9 Group.

For an EV charging circuit, check the charging equipment's DC leakage requirements separately. Select the breaker against the operating current, sensitivity and fault rating specified for the W9 version.

01

Select load and overcurrent duty

Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.

02

Specify residual-current response

Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.

03

Check the EV protection arrangement

For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.

04

Confirm pole and terminal wiring

Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.

Before specifying JCB2LE-EV: Confirm operating voltage, charger DC protection, pole wiring and installation requirements for the exact offered RCBO.

ABOUT W9 GROUP

W9 Group support for JCB2LE-EV RCBO

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB2LE-EV enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

Cable size, terminal torque and contact life

The JCB2LE-EV schedule gives separate cable and busbar capacities, even though both share a terminal tightening specification. It also distinguishes electrical endurance under load from mechanical endurance. Use the W9 product table for the breaker current, leakage sensitivity and breaking capacity.

Additional JCB2LE-EV technical data
Parameter Value
Standards listed IEC61009-1, EN61009-1
Rated operating voltage (V) 230/240
Insulation voltage (V) 500
Rated frequency 50/60Hz
Impulse withstand voltage (V) 6,000
Power-frequency dielectric test, 1 minute (kV) 2
Pollution degree 2
Electrical endurance (operations) 2,000
Mechanical endurance (operations) 10,000
Contact position indicator Yes
Degree of protection IP20
Thermal reference temperature (°C) 30
Ambient range (°C); daily average ≤35 °C -5 … +40
Storage temperature (°C) -25 … +70
Connection type Cable/U-type busbar/Pin-type busbar
Cable terminal capacity 25mm2/18-3AWG
Busbar terminal capacity 10mm2/18-8AWG
Terminal tightening torque 2.5N*m/22In-lbs
Rail mounting On DIN rail EN 60715(35mm)
Supply connection From top or bottom are available

RELATED RESOURCES

JCB2LE-EV Type A residual current protection documents

Use technical support and related products to specify JCB2LE-EV. Request a datasheet and wiring diagram matching the selected JCB2LE-EV configuration.

BUYER FAQ

JCB2LE-EV two pole RCBO FAQs

Find answers about JCB2LE-EV selection, configuration and ordering.

Which protection functions are combined?

The summary identifies residual-current, overload and short-circuit protection in an electronic two-pole device. Confirm the complete ordered version.

Which current and curve options are listed?

W9 Group lists 32A and 40A, with B or C overcurrent characteristics. Select the curve using load starting behavior and the required conductor protection.

Does Type A mean smooth DC detection is included?

No smooth DC detection threshold is established by this target summary. Confirm the charger’s DC detection and the required upstream arrangement separately.

What residual-current sensitivity is listed?

The summary lists 30mA. Confirm the required sensitivity and exact protection arrangement against the charger instructions and installation rules.

Does this RCBO include open-PEN protection?

An independent open-PEN function is not established for the target product. Confirm any required separate protection instead of inferring it from the EV name.

Can the supply enter from either end?

The summary describes top and bottom wiring. Confirm the permitted supply terminals, neutral path and test-circuit operation from the matching installation drawing.

What is needed for a JCB2LE-EV quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a JCB2LE-EV 2 pole RCBO quotation

Tell W9 Group your complete order code, circuit duty, installation conditions and required documents, quantity and destination market so the selected configuration can be identified.

Contact W9 Group