JC3BE miniature circuit breaker
The JC3BE miniature circuit breaker provides overload and short-circuit protection for electrical distribution circuits. It has a contact indicator and several pole options. Ask W9 Group to confirm the breaking capacity for your chosen current rating and operating voltage.
- Overload and short-circuit protection
- 1P, 2P, 3P and 4P configurations
- B, C and D catalogue trip-curve options
- Contact-position indicator
- IEC 60947-2 catalogue reference
- Residential, commercial and industrial distribution
PRODUCT OVERVIEW
JC3BE MCB for Building and Industrial Distribution
The JC3BE is used in residential, commercial and industrial distribution systems. It disconnects the circuit when an overload or short circuit trips the breaker. The contact indicator shows the device state.
The product information gives different breaking capacities for different current ranges. Select the breaker using its current, voltage and short-circuit rating together. Do not apply the largest published breaking capacity to every version.
JC3BE Trip Characteristics and Configuration Options
- Contact indication and poles
- The supplier lists a contact-position indicator and one-, two-, three- and four-pole versions. Select the pole arrangement for the supply and neutral requirements of the circuit.
- B, C and D catalogue options
- B, C and D trip characteristics are listed with an IEC 60947-2 reference. Ask for the curve and test documentation for the selected product code, including the breaking capacity at its rated current and operating voltage.
JC3BE Applications in Residential and Industrial Boards
The supplier lists residential installations, commercial distribution and industrial electrical distribution systems. Select the breaker for the individual circuit within that system, taking account of the load, cable and fault current at the board.
TECHNICAL DATA
JC3BE Miniature Circuit Breaker Specifications
Use the table as a summary of the available product information. Ask for the current-specific and voltage-specific rating before choosing the breaker.
| Model | JC3BE |
|---|---|
| Protection functions | Overload and short circuit |
| Listed current limit | Up to 63A |
| Pole options | 1 pole, 2 pole, 3 pole, 4 pole |
| Breaking capacity | Confirm the current-specific and voltage-specific rating schedule |
| Contact indication | Listed by the supplier |
SELECTION GUIDE
JC3BE MCB Selection: Network Conditions and Load Characteristics
Select the breaker from the circuit conditions at the installation point and the starting behaviour of the load.
Earthing, voltage and available fault current
Identify the earthing arrangement, including TN-S or TN-C where applicable, and the normal supply voltage. Check that the available short-circuit current does not exceed the breaking capacity of the chosen current and voltage configuration.
B and C characteristics
The supplier associates B curves with lower-inrush circuits and longer cable runs, and C curves with resistive or inductive loads with modest starting current. Check the disconnection conditions for the circuit as well as the load starting current.
D characteristics for high-inrush loads
D curves are described for loads such as transformers and discharge lighting. The catalogue lists more than one D-curve threshold; obtain the trip curve for the ordered breaker rather than applying one threshold to every version.
ABOUT W9 GROUP
Buying JC3BE Circuit Breakers from W9 Group
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. Contact W9 Group about JC3BE specifications, installation documents or branding requirements for your order.

RELATED RESOURCES
JC3BE Datasheets and Technical Support
Need a JC3BE datasheet, wiring diagram or trip curve? Contact technical support with the current rating and pole configuration you need. You can also browse the product range and the W9 Group download centre below.
RELATED PRODUCTView the JCB3-125 product pageReview this model separately to compare its ratings and connection requirements.
DOCUMENTSVisit the download centreBrowse available documents. If the JC3BE file is missing, contact technical support.
BUYER FAQ
JC3BE Circuit Breaker FAQs
Answers to common questions about ratings, wiring, installation and ordering.
Is every JC3BE rated at 25 kA?
No. The description lists 15kA and says the 1A–40A range can reach 25kA. Ask which rating applies to the selected current, voltage and test conditions.
Which current ratings can I order?
The product summary gives a maximum of 63A, but does not list every order option. Ask W9 Group for the available ratings and trip curves.
Which pole configuration should I choose?
The summary lists one through four poles. Select the version for the supply and neutral arrangement, using its wiring diagram.
Can the same JC3BE be used on AC and DC?
Do not assume both ratings. Ask for the AC or DC rating for the exact version and operating voltage you intend to use.
Does the contact indicator prove the circuit is safe to work on?
No. It does not replace the required isolation procedure or a test for absence of voltage. Follow the installation and maintenance instructions.
Does the JC3BE protect against earth leakage?
The stated functions are overload and short-circuit protection. Use a suitable residual-current device or combined RCBO where earth-leakage protection is required.
What should I send for a JC3BE quotation?
Send W9 Group your required supply type and voltage, rated current, pole configuration and trip curve, quantity and destination country. Include any wiring, accessory or documentation requirements. Ask for price and delivery time for the proposed version.
PRODUCT ENQUIRY
Get a Quote for JC3BE Circuit Breakers
Send W9 Group your required supply type and voltage, rated current, pole configuration and trip curve, quantity and destination country.
Include any wiring, accessory or documentation requirements. Ask for price and delivery time for the proposed version.