RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole
W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.
- Four main poles plus an alarm section
- Leakage, overload and short-circuit protection
- DIN-rail mounting and insulated busbar openings
JCB2LE-80M4P+A four-pole RCBO with alarm indication
This variant combines a four-pole RCBO with an alarm contact. The RCBO protects the outgoing circuit; the alarm connection lets a separate monitoring circuit register the trip. The alarm is a signalling function, not an additional load pole.





TECHNICAL DATA
JCB2LE-80M4P+A 6kA 4 Pole RCBO with Alarm Specifications
W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.
| Standard | IEC61009-1 , EN61009-1 | |
| Electrical features | Rated current In (A) | 6, 10, 16, 20, 25, 32, 40,50,63,80 |
| Type | Eletronic | |
| Type (wave form of the earth leakage sensed) | A or AC are available | |
| Poles | 4 Pole | |
| Rated voltage Ue(V) | 230/240 | |
| Rated sensitivity I△n | 30mA,100mA | |
| Insulation voltage Ui (V) | 500 | |
| Rated frequency | 50/60Hz | |
| Rated breaking capacity | 6kA | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 6000 | |
| Pollution degree | 2 | |
| Thermo-magnetic release characteristic | B, C | |
| Mechanical features | Electrical life | 2, 000 |
| Mechanical life | 2, 000 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Reference temperature for setting of thermal element(℃) | 30 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25mm2 / 18-4 AWG | |
| Terminal size top/bottom for Busbar | 10mm2 / 18-8 AWG | |
| Tightening torque | 2.5 N*m / 22 In-Ibs. | |
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
| Connection | From top or bottom are available |
JCB2LE-80M4P+A product details in pictures



SELECTION GUIDE
Selecting a 4 Pole RCBO with Alarm and Type A or AC Options
Specify the rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents when requesting a JCB2LE-80M4P+A quotation from W9 Group.
Allow room for the alarm section as well as the four main poles. Include the alarm wiring requirement, trip curve and residual-current sensitivity when specifying the board.
Specify the alarm interface
Request the alarm-contact diagram, contact ratings and operating behavior required by the monitoring circuit.
Confirm supply voltage
State the circuit’s supply voltage and request confirmation of the voltage marked on the selected alarm RCBO.
Choose current and curve
The product lists a 6–80 A range with B or C curves. Include the required rating and curve in the enquiry.
Specify leakage detection
State the required waveform type and sensitivity. Confirm both for the selected JCB2LE-80M4P+A configuration.
ABOUT W9 GROUP
W9 Group 4 Pole RCBO with Alarm Supply and Support
Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M4P+A order, contact W9 Group about the required configuration and product documents.

Reading the four-pole alarm-version drawing
The four main poles carry the protected circuit. The additional alarm connection is for signalling. Use the alarm-version sheet to identify this arrangement; a four-pole drawing without the alarm contact is insufficient for planning the monitoring wiring.
JCB2LE-80M4P+A supplier datasheet (PDF) Four-pole version with alarm contact.
RELATED RESOURCES
JCB2LE-80M4P+A 4 Pole RCBO with Alarm Technical Document Requests
Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M4P+A configuration.
PRODUCT DIRECTORYExplore W9 Group circuit-protection productsBrowse the product directory to compare RCBO models
DOCUMENTSW9 Group download centreRequest the current document for your quoted JCB2LE-80M4P+A variant
BUYER FAQ
RCBO FAQs: Alarm, Current and Sensitivity Checks
Find answers about configuration, installation documents and ordering.
What distinguishes the alarm version?
JCB2LE-80M4P+A is listed as an RCBO with alarm for circuit monitoring. Request the alarm wiring diagram and contact data for the required monitoring interface.
How should voltage and sensitivity be selected?
Provide the supply voltage and required residual-current sensitivity. Ask W9 Group to confirm the ratings for the quoted alarm RCBO before approving the order.
Which current range and trip curves are listed?
The product information lists a 6–80 A range and B or C curves. Confirm the exact current, curve and alarm configuration on the quotation.
What is needed for a JCB2LE-80M4P+A quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.
What alarm-contact wiring data is needed for JCB2LE-80M4P+A?
Request the alarm terminal diagram, signal-contact duty and reset sequence for the quoted JCB2LE-80M4P+A. Confirm the external signaling circuit separately from the protected power circuit.
How do I check JCB2LE-80M4P+A fault-duty coordination?
Provide the supply voltage and prospective short-circuit current, then request the breaking-capacity and coordination documents for the exact current and pole configuration.
Which dimensions should I check before fitting the four-pole alarm RCBO?
Request the JCB2LE-80M4P+A outline and connection drawing. Confirm the device width, terminal clearance and alarm-wiring space against the distribution-board layout.
PRODUCT ENQUIRY
Request a JCB2LE-80M4P+A 4 Pole RCBO with Alarm Quotation
Tell W9 Group your rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents, quantity and destination market so the selected configuration can be identified.