Circuit Protection Products

HomeProductsCircuit Protection ProductsWLM6RT-1250 adjustable MCCB
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 1
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 2
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 3
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 4
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 5
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 6
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 7
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 8
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 9
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 10
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 1
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 2
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 3
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 4
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 5
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 6
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 7
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 8
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 9
  • Adjustable mccb WLM6RT-1250A-3300 3P WLM6RT Series Moulded Case Circuit Breaker400V/690V mccb 800A 3 Poles Gallery image 10

WLM6RT-1250 adjustable MCCB

The WLM6RT-1250 adjustable MCCB is listed by W9 Group with a 1250 A summary rating and 3P / 4P options. The catalog separates adjustable releases by suffix. Match the ordered current, overload and instantaneous functions, operating voltage and fault duty before selecting a breaker for the panel. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

WLM6RT-1250 3 Pole and 4 Pole Adjustable MCCB Specifications

The WLM6RT-1250 adjustable MCCB is listed by W9 Group with a 1250 A summary rating and 3P / 4P options. The catalog separates adjustable releases by suffix. Match the ordered current, overload and instantaneous functions, operating voltage and fault duty before selecting a breaker for the panel.

WLM6RT Moulded Case Circuit Breaker 1250
Rated operating current In (A),40℃ Thermal-magnetic type 630-700-800-1000-1250
WLM6RT/Adjustable type 630-700-800-1000-1250
WLM6RT/A/Adjustable type Ir 630-700-800-1000-1250
WLM6RT/P/Adjustable type li 630-700-800-1000-1250
Electric characteristics
Rated insulation voltage Ui (V) 1000
Rated impulse withstand voltage (kV) 8
Rated operational voltage Ue(V),AC 50/60Hz 380/400/415,440,500,660/690
Breaking capacity code S M H
Number of poles 1P(Adjutable has no this type) – – –
2P – – –
3P ■ ■ ■
4P ■ ■ ■
Number of poles AC220/230/240V 60 80 85
AC380/400/415V 50 70 100
AC440V – – –
AC500V – – –
AC660/690V 20 25 35
Number of poles AC220/230/240V 40 65 70
AC380/400/415V 35 50 70
AC440V – – –
AC500V – – –
AC660/690V 10 15 20
Standard
Utilization category A(Thermal-magnetic)/B(Electronic)
Ambient temperature
Safety of insulation ■
Arcing distance 0
Mechanical life
(CO recycle)
Maintenance 8000
Electrical life
(CO recycle)
AC415V,In 1000
AC690V,In 800
Release units
Distribution protection TM ■
Motor protection TM ■
Mounting and connection
Fixed Front connection –
Rear connection ■
Plug-in Front connection –
Rear connection –
Draw-out Front connection ■
Rear connection ■
DIN rail Front connection –
Dimension
Dimension (mm)
W×H×D
Width (1P/2P/3P/4P) 210/280
Height 275.5
Depth 103
Weight
Distribution protection 1P –
2P –
3P 8.9
4P 11.931

SELECTION GUIDE

How to Select a 1250A MCCB with Adjustable Overload or Instantaneous Trip

Specify the ordered current, release suffix, adjustment functions, poles, operating voltage and fault duty when requesting a WLM6RT-1250 quotation from W9 Group.

01

Select the current and release

Use WLM6RT-1250 with the required catalog current. Confirm whether the selected release adjusts overload, instantaneous protection or both.

02

Coordinate the protection curve

Request the time-current curve and allowed settings for the actual release. Match the settings to the load and adjacent protective devices.

03

Match voltage and fault duty

Provide circuit voltage and prospective short-circuit current. Confirm the capacity code and corresponding Icu / Ics.

04

Check the installation drawing

Confirm pole count, terminal direction, mounting form, clearances and dimensions before preparing the switchboard.

Before specifying WLM6RT-1250: Confirm the complete release suffix and matched fault-duty data. Catalog current choices and a series description do not establish the settings or installation dimensions of every ordered version.

ABOUT W9 GROUP

W9 Group 1250A Adjustable MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6RT-1250 enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

WLM6RT-1250 Adjustable MCCB Trip Curves, Wiring and Mounting Documents

Use technical support and related products to specify WLM6RT-1250. Request a datasheet and wiring diagram matching the selected WLM6RT-1250 configuration.

BUYER FAQ

WLM6RT-1250 Adjustable MCCB FAQs: Trip Settings, Poles and Fault Ratings

Find answers about WLM6RT-1250 selection, configuration and ordering.

Which current choices are listed for WLM6RT-1250?

The target catalog lists 630, 700, 800, 1000, 1250 A. These are available catalog choices, not a promise that every release adjusts continuously across the full range. Confirm the ordered current and suffix.

Does every version adjust both overload and instantaneous protection?

The catalog separates adjustable variants by suffix. Confirm each required adjustment function, setting range and time-current curve for the supplied release.

Can the same breaking capacity be used at both operating voltages?

Confirm Icu / Ics for the actual voltage, pole arrangement and capacity code. The source matrix has ambiguous headings, so no single fault rating is assigned to every version.

How do I select the pole arrangement?

The summary offers 3P / 4P. Specify neutral switching requirements and request the drawing matching the selected arrangement.

Is this an electronic controller or a thermal-magnetic release?

This page covers the adjustable thermal-magnetic model designation. Confirm its release suffix; electronic-controller functions from other product families are not included by assumption.

Which mounting and connection details need confirmation?

Request the approved drawing for fixed, plug-in or withdrawable construction as applicable. Confirm front or rear connection, terminal clearances and the ordered accessory combination.

What is needed for a WLM6RT-1250 quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a WLM6RT-1250 Adjustable MCCB Quotation

Tell W9 Group your ordered current, release suffix, adjustment functions, poles, operating voltage and fault duty, quantity and destination market so the selected configuration can be identified.

Contact W9 Group