조정 가능한 MCCB CSDM7R-800L-3300 3P CSDM7R 시리즈 몰드 케이스 회로 차단기 차단기 400V/690V 800A 3폴
기술 데이터
CSDM7R-800L-3300 800A 3P Adjustable MCCB Information
W9 Group lists CSDM7R-800L-3300 as an 800A three-pole adjustable molded case circuit breaker with 400V/690V designations. Include the full model, required poles and release settings in the enquiry so W9 Group can confirm the offered configuration.
The title identifies 800A and 3P, while the original table lists 400 and 250-315-350-400; an older summary also states 4P. Confirm the ordered current and poles against the nameplate and matching drawing.
| CSDM7R-800L- 3300 Moulded Case Circuit Breaker | 400 | |||||||||||||
| 정격 작동 전류(A) 40℃ | 열-자기 유형 | 250-315-350-400 | ||||||||||||
| CSDM7R-800L- 3300/Adjustable type | 250-315-350-400 | |||||||||||||
| CSDM7R-800L- 3300/A/Adjustable type Ir | 250-315-350-400 | |||||||||||||
| CSDM7R-800L- 3300/P/Adjustable type li | 250-315-350-400 | |||||||||||||
| 전기 특성 | ||||||||||||||
| 등급된 절연 전압 Ui(V) | 1000 | |||||||||||||
| 정격 인덕션 저항 전압 (kV) | 8 | |||||||||||||
| 운용 전압 Ue(V), AC 50/60Hz | 380/400/415,440,500,660/690 | |||||||||||||
| 차단 용량 코드 | C | S | M | H | Q | |||||||||
| 폴 수 | 1P(Adjustable에는 이 타입이 없습니다) | – | – | – | – | – | ||||||||
| 2P | – | – | – | – | – | |||||||||
| 3P | ■ | ■ | ■ | ■ | ■ | |||||||||
| 4P | ■ | ■ | ■ | ■ | ■ | |||||||||
| 폴 수 | AC220/230/240V | – | 50 | 65 | 70 | – | ||||||||
| AC380/400/415V | – | 30 | 70 | 100 | 150 | |||||||||
| AC440V | – | – | – | – | – | |||||||||
| AC500V | – | – | – | – | 65 | |||||||||
| AC660/690V | – | 8 | 20 | 25 | 20 | |||||||||
| 폴 수 | AC220/230/240V | – | – | – | – | – | ||||||||
| AC380/400/415V | – | 15 | 50 | 70 | 150 | |||||||||
| AC440V | – | – | – | – | – | |||||||||
| AC500V | – | – | – | – | 65 | |||||||||
| AC660/690V | – | 4 | 10 | 4 | 20 | |||||||||
| 표준 | ||||||||||||||
| 이용 범주 | A | |||||||||||||
| 기온 | ||||||||||||||
| 절연재의 안전성 | ■ | |||||||||||||
| 회전 거리 | 0 | |||||||||||||
| 기계적 수명 | 보수 | 15000 | ||||||||||||
| (CO 재활용) | ||||||||||||||
| 전기 수명 | AC415V,In | 8000 | ||||||||||||
| (CO 재활용) | AC690V,In | 1500 | ||||||||||||
| 릴리스 단위 | ||||||||||||||
| 유통 보호 | TM | ■ | ||||||||||||
| 모터 보호 | TM | ■ | ||||||||||||
| 장착 및 연결 | ||||||||||||||
| 수정됨 | 전면 연결 | ■ | ||||||||||||
| 후면 연결 | ■ | |||||||||||||
| 플러그인 | 전면 연결 | ■ | ||||||||||||
| 후면 연결 | ■ | |||||||||||||
| 끌어내는 것 | 전면 연결 | – | ||||||||||||
| 후면 연결 | – | |||||||||||||
| DIN 레일 | 전면 연결 | ■ | ||||||||||||
| 차원 | ||||||||||||||
| 치수 (mm) | 폭(3P/4P) | 140/184 | ||||||||||||
| W×H×D | 키 | 257 | ||||||||||||
| 깊이 | 103/111(Q type) | |||||||||||||
| 체중 | ||||||||||||||
| 유통 보호 | 1P | – | ||||||||||||
| 2P | – | |||||||||||||
| 3P | 4.68 | |||||||||||||
| 4P | 6.314 | |||||||||||||
선정 가이드
Selecting CSDM7R-800L-3300 800A 3P adjustable MCCB for Your Installation
Use CSDM7R-800L-3300 as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
Confirm the complete rating schedule
Provide the required current, circuit voltage and poles. Request a matching order-code datasheet and confirmed nameplate details before selection.
Specify adjustment functions
Request the release legend, setting increments and time-current curve. Confirm which overload and instantaneous functions are adjustable on the offered version.
Coordinate short-circuit protection
Supply the prospective fault current and adjacent protective devices. Request the applicable Icu and Ics at the intended operating voltage.
Check mounting and connection
Request the exact mounting form, dimensions, terminals and wiring instructions. Confirm any accessories and neutral arrangement separately.
W9 그룹 소개
W9 Group Support for CSDM7R-800L-3300 Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a CSDM7R-800L-3300 enquiry, contact W9 Group about configuration and matching product documents.

관련 자료
Request CSDM7R-800L-3300 MCCB Trip Curves and Wiring Drawings
Use technical support and related products to specify CSDM7R-800L-3300. Request a datasheet and wiring diagram matching the selected CSDM7R-800L-3300 configuration.
구매자 FAQ
CSDM7R-800L-3300 MCCB Current, Pole and Trip-Unit FAQs
Find answers about CSDM7R-800L-3300 selection, configuration and ordering.
Which configuration does the CSDM7R-800L-3300 title identify?
Use the complete CSDM7R-800L-3300 designation as the enquiry reference. Confirm the selected nameplate current, number of poles and trip-unit code together on the quotation and matching datasheet.
How do I confirm the CSDM7R-800L-3300 current and pole configuration?
Request a nameplate photograph and a current-and-pole schedule identifying the exact CSDM7R-800L-3300 order code. Confirm any difference between the catalogue title and legacy technical information before approving the breaker.
Which CSDM7R-800L-3300 trip-curve information should I request?
Request the complete release code, time-current curve and setting instructions for CSDM7R-800L-3300. Confirm the available adjustment functions and compare the selected release with the load and upstream protection.
How should I check the CSDM7R-800L-3300 breaking capacity?
Provide the operating voltage and prospective short-circuit current. Request the applicable Icu and Ics schedule for the exact CSDM7R-800L-3300 order code, including its test conditions.
Which CSDM7R-800L-3300 dimensions are needed before panel manufacture?
Request the outline, fixing positions and terminal drawing for the selected CSDM7R-800L-3300 pole arrangement. Confirm conductor access and busbar spacing before preparing the panel.
How do I confirm CSDM7R-800L-3300 accessory compatibility?
Provide the full CSDM7R-800L-3300 breaker and release codes, together with the required accessory function. Request written confirmation of the mounting and control-supply combination.
What should I send for a CSDM7R-800L-3300 quotation?
Send the complete CSDM7R-800L-3300 designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete CSDM7R-800L-3300 designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request CSDM7R-800L-3300 Pricing and Technical Documents
Tell W9 Group your complete model, selected current, poles, operating voltage, release settings and fault duty, quantity and destination market so the selected configuration can be identified.






































