محصولات صنعتی

  • قطع‌کننده MCCB WLM6LY-630A-4300 نوع 4P WLM6L سری قطع‌کننده حفاظت از نشت زمین 400 ولت 630 آمپر 3 پین 4 پین
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 6
  • قطع‌کننده MCCB WLM6LY-630A-4300 نوع 4P WLM6L سری قطع‌کننده حفاظت از نشت زمین 400 ولت 630 آمپر 3 پین 4 پین
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-630A-4300 4P WLM6L Series earth leakage protection type circuit breaker 400V 630a 3 poles 4 Poles Gallery image 6

WLM6LY-630 earth leakage MCCB

The WLM6LY-630 earth leakage MCCB is listed by W9 Group with a 630 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

اطلاعات فنی

WLM6LY-630 Earth Leakage MCCB Specifications

The WLM6LY-630 earth leakage MCCB is listed by W9 Group with a 630 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6LY-630 product specifications
مدل WLM6LY-630
رشته محصولات Earth leakage molded case circuit breaker
خلاصه جریان ورودی 630 A
Catalog current choices 400, 500, 630 A
Summary pole options 3P / 4P; confirm the complete order code
Voltage selection 400 V AC appears in the summary and table; confirm voltage for the selected configuration
Overcurrent release listed Thermal
Leakage release listed الکترونیک
Residual-current type listed AC; confirm suitability for the expected waveform
تنظیم ولتاژ عایق Ui 1000 ولت
تخلف ولتاژ ناگهانی Uimp 8 kV
Leakage alarm without tripping Shown as an option; confirm availability and intended alarm / trip mode
Standard listed IEC / EN 60947-2; request applicable model documents

راهنمای انتخاب

Selecting a 630A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-630 quotation from W9 Group.

01

Choose the ordered current

The 630 A page lists 400, 500, 630 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-630: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

درباره W9 Group

W9 Group 630A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-630 enquiry, contact W9 Group about configuration and matching product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

WLM6LY-630 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-630. Request a datasheet and wiring diagram matching the selected WLM6LY-630 configuration.

سوالات متداول خریداران

WLM6LY-630 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-630 selection, configuration and ordering.

Which current choices are listed for WLM6LY-630?

The summary identifies 630 A. The frame schedule lists 400, 500, 630 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

Is this an RCCB without overcurrent protection?

The target table describes a molded-case device with overcurrent and leakage releases. Confirm the complete protection functions in the matching datasheet; generic RCCB text is insufficient to classify the ordered unit.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-630 quotation?

اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونه‌ها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.

سؤال و جواب درباره محصول

Request a WLM6LY-630 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

تماس با گروه W9