فوتونورژی

  • قطع‌کن مدار هوایی WEW3-4000 نوع ACB، نوع قابل‌برداشتن، نوع ثابت، ولتاژ 1000VAC/1500VAC، جریان 4000A، نوع 3p، نوع ACB 4p
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4
  • قطع‌کن مدار هوایی WEW3-4000 نوع ACB، نوع قابل‌برداشتن، نوع ثابت، ولتاژ 1000VAC/1500VAC، جریان 4000A، نوع 3p، نوع ACB 4p
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-4000 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4

قطارکننده هوایی WEW3-4000

The WEW3-4000 air circuit breaker is listed by W9 Group with a 4000 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code. Request the selected configuration and matching technical documents from W9 Group.

اطلاعات فنی

WEW3-4000 3 Pole and 4 Pole Air Circuit Breaker Specifications

The WEW3-4000 air circuit breaker is listed by W9 Group with a 4000 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code.

WEW3 Air Circuit Breaker 4000
شارح جریان کاری در حالت (A)، ۴۰ درجه سانتیگراد 2000-2500-2900-3200-3600-3900-4000
ولتاژ عایقی مجاز Ui (V) 1000
تولید برق با ولتاژ انقباضی (kV) 12
ولتاژ عملیاتی تعیین شده Ue(V)، AC 50/60Hz ۴۰۰ ولت/۶۹۰ ولت
از دسته استفاده کنید B
ولتاژ عملیاتی تعیین شده Ue(V)، AC 50/60Hz 100%In
رمز توانایی شکست M H
تعداد ستون ۳P ■ ■
۴P ■ ■
بهترین رتبه
قطع مدار
ظرفیت آیکی (kA)
AC380V/400V/415V 100 138
AC690V 65 105
AC800V/1140V 80 138
خرابی خدمات رتبهبندی شده
توانایی Ics (kA)
AC380V/400V/415V 65 105
AC690V 80 138
AC800V/1140V 65 105
مقدار مقاومت در زمان کوتاه 
Icw فعلی (kA/1s)
AC380V/400V/415V 80 138
AC690V 65 105
AC800V/1140V – –
زمان کارکرد مکانیکی
(بازیافت CO)
خدمات نگهداری 20000
زندگی الکتریکی
(بازیافت CO)
AC415V، در 6000
AC690V، در 2000
تجهیزات استاندارد رفع اشکال Drawetry-pe
بدنه قطع کننده مدار ■ ■
باطری کشو ■ ■
کنترل کننده هوشمند ■ ■
سیم‌های اتصال افقی بالایی و پایینی ■ ■
نمودار نشان‌دهنده تماس باز/ بسته شدن ■ ■
نمودار نشانگر تماس با پریز خطا ■ ■
کنترلر جانبی 4NO+4NC ■ ■
سیستم عملیاتی موتور الکتریکی ■ ■
رفع جریان شنت ■ ■
لوازم جانبی اختیاری
تقسیم فاز □ □
سوزش ناگهانی ولتاژ □ □
خروج از ولتاژ تأخیر زمانی □ □
قفل دکمه باز و بسته شدن □ □
قفل برای پایه کشو □ □
قفل برای موقعیت جدایی صندلی کشو □ □
کلید قفل □ □
گیربندی درب □ □
کنترلر جانبی 6NO+6NC □ □
نشان‌دهی‌های الکتریکی سه موقعیت بر روی پایه کشو □ □
تداخل کابل فولادی □ □
گیربندی متقابل □ □
کنترلگر دوگانه قدرت □ □
ترانسفورماتور خط خنثی خارجی □ □
ترانسفورماتور صفر-روند □ □
ترانسفورماتور جریان زمین و لوازم جانبی آن □ □
ابعاد
ابعاد (میلی متر)
عرض × ارتفاع × عمق
عرض (3P/4P) 66/105 66/105
ارتفاع 57/60 60/62
عمق 60/62 57/61
وزن
وزن (کیلوگرم)/ثابت ۳P 83/83
۴P 110.2/125.2
وزن (کیلوگرم) / کشو ۳P 122/150
۴P 155/175

راهنمای انتخاب

How to Select a 4000A Fixed or Withdrawable Air Circuit Breaker

Specify the ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements when requesting a WEW3-4000 quotation from W9 Group.

01

Define the current and frame

State WEW3-4000, the ordered current and continuous load. Confirm the selected controller and any derating conditions.

02

Match the application voltage

Provide system voltage and prospective fault current. Request a matched rating table rather than relying on a generic solar application title.

03

Choose fixed or withdrawable

Confirm the construction, base, interlocks, terminal arrangement and maintenance access on the installation drawing.

04

Specify the control package

List required trip functions, operating supply, auxiliary feedback and communication needs. Confirm each item in the supplied bill of materials.

Before specifying WEW3-4000: Confirm the complete model, voltage, controller and fault-duty documentation. Series solar wording does not establish extended-voltage or outdoor suitability for the supplied breaker.

درباره W9 Group

W9 Group 4000A Air Circuit Breaker Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WEW3-4000 enquiry, contact W9 Group about configuration and matching product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

WEW3-4000 ACB Wiring, Icu, Ics and Icw Document Requests

Use technical support and related products to specify WEW3-4000. Request a datasheet and wiring diagram matching the selected WEW3-4000 configuration.

سوالات متداول خریداران

WEW3-4000 Air Circuit Breaker FAQs: Fault Ratings and Trip Controllers

Find answers about WEW3-4000 selection, configuration and ordering.

Which current choices are listed for WEW3-4000?

The target table lists 2000, 2500, 2900, 3200, 3600, 3900, 4000 A. Confirm the ordered current, controller range and any enclosure or temperature derating.

Does the listing establish every voltage mentioned in the old title?

Use a matched rating document for the offered device. The summary, title and some table entries differ; no extended-voltage suitability is promised from the title alone.

How do fixed and withdrawable versions differ for ordering?

State the required construction and confirm the supplied base, position indication, interlocks, terminals and installation dimensions for that version.

آیا Icu، Ics و Icw رتبهبندی‌های یکسان هستند؟

Request all required ratings separately at the project voltage. Confirm the short-time withstand duration and the controller settings used in the coordination study.

Does every controller include ground-fault protection or communication?

A series configuration list does not establish every controller function. Confirm the exact controller code, sensing arrangement, protection functions and communication interface.

Can the breaker be installed outdoors without an enclosure?

The available listing does not establish a complete outdoor enclosure specification. Confirm the switchboard protection, environmental conditions and installation requirements; generic waterproof wording is not a device rating.

What is needed for a WEW3-4000 quotation?

اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونه‌ها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.

سؤال و جواب درباره محصول

Request a WEW3-4000 Air Circuit Breaker Quotation

Tell W9 Group your ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements, quantity and destination market so the selected configuration can be identified.

تماس با گروه W9