Circuit Protection Products

HomeProductsCircuit Protection ProductsWLM6RT-160 adjustable MCCB
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 1
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 2
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 3
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 4
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 5
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 6
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 7
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 8
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 9
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 10
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 11
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 12
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 13
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 14
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 15
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 1
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 2
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 3
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 4
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 5
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 6
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 7
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 8
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 9
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 10
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 11
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 12
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 13
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 14
  • Adjustable Mccb WLM6RT-160A-3300 3P WLM6RT Series thermal magnetic type mccb 400V/690V mccb 125A 3 Poles Gallery image 15

WLM6RT-160 adjustable MCCB

The WLM6RT-160 adjustable thermal-magnetic MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. The catalog separates adjustable variants by suffix. Select the current, release configuration and voltage-specific fault duty before requesting the matching time-current curves. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

WLM6RT-160 Adjustable MCCB Specifications and Current Options

The WLM6RT-160 adjustable thermal-magnetic MCCB is listed by W9 Group with a 160 A summary rating and 3P / 4P options. The catalog separates adjustable variants by suffix. Select the current, release configuration and voltage-specific fault duty before requesting the matching time-current curves.

WLM6RT Moulded Case Circuit Breaker 160
Rated operating current In (A),40℃ Thermal-magnetic type 16-20-25-32-40-50-63-80-100-125-160
WLM6RT/Adjustable type 25-32-40-50-63- 80-100-125-140-160
WLM6RT/A/Adjustable type Ir 25-32-40-50-63- 80-100-125-140-160
WLM6RT/P/Adjustable type li 25-32-40-50-63- 80-100-125-140-160
Electric characteristics
Rated insulation voltage Ui (V) 1000
Rated impulse withstand voltage (kV) 8
Rated operational voltage Ue(V),AC 50/60Hz 380/400/415,440,500,660/690
Breaking capacity code C S M H
Number of poles 1P(Adjutable has no this type) – – – –
2P ■ ■ – –
3P ■ ■ ■ ■
4P ■ ■ ■ ■
Number of poles AC220/230/240V – – – –
AC380/400/415V 30 35 50 65
AC440V – – – –
AC500V – – – –
AC660/690V 8 6 10 15
Number of poles AC220/230/240V – – – –
AC380/400/415V 20 25 35 50
AC440V – – – –
AC500V – – – –
AC660/690V 2 3 5 10
Standard
Utilization category A
Ambient temperature
Safety of insulation ■
Arcing distance 0
Mechanical life
(CO recycle)
Maintenance 15000
Electrical life
(CO recycle)
AC415V,In 8000
AC690V,In 1500
Release units
Distribution protection TM ■
Motor protection TM ■
Mounting and connection
Fixed Front connection ■
Rear connection ■
Plug-in Front connection ■
Rear connection ■
Draw-out Front connection –
Rear connection –
DIN rail Front connection ■
Dimension
Dimension (mm)
W×H×D
Width (1P/2P/3P/4P) -/60/90/120
Height 152
Depth 68/82
Weight
Distribution protection 1P –
2P 1.1
3P 1.501
4P 1.909

SELECTION GUIDE

Selecting a 160A Adjustable Thermal-Magnetic MCCB Trip Unit

Specify the selected current, release suffix, adjustment functions, poles, operating voltage, fault duty and panel arrangement when requesting a WLM6RT-160 quotation from W9 Group.

01

Identify the current and suffix

The adjustable catalog row lists 25–160 A choices. Confirm the ordered rating and whether overload, instantaneous or both settings are adjustable.

02

Match the time-current curve

Request the selected trip curve and permitted setting ranges. Confirm coordination with the load and upstream / downstream protection.

03

Check voltage and fault capacity

Specify the operating voltage and prospective short-circuit current. Confirm Icu / Ics for the actual pole and capacity-code combination.

04

Verify panel integration

Request dimensions, terminal arrangement, mounting and clearances for the selected version. Confirm every suffix-dependent dimension before assembly.

Before specifying WLM6RT-160: Confirm the 160 A model identity, ordered current and release suffix. The old title contains a conflicting current, and series setting descriptions do not prove every variant has both adjustment functions.

ABOUT W9 GROUP

W9 Group 160A Adjustable MCCB Supply and Technical Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6RT-160 enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

WLM6RT-160 Adjustable MCCB Trip Curves and Installation Documents

Use technical support and related products to specify WLM6RT-160. Request a datasheet and wiring diagram matching the selected WLM6RT-160 configuration.

BUYER FAQ

WLM6RT-160 Adjustable MCCB FAQs: Settings, Poles and Fault Duty

Find answers about WLM6RT-160 selection, configuration and ordering.

Is the WLM6RT-160 page for a 125 A or 160 A breaker?

The native summary and frame table identify 160 A. The old title also contains 125 A. Confirm the ordered current and full suffix rather than relying on that mixed title.

Which adjustable-variant currents are listed?

The adjustable rows list 25, 32, 40, 50, 63, 80, 100, 125, 140 and 160 A. These are catalog choices; confirm the adjustment limits of the actual release.

Are overload and instantaneous settings adjustable on every version?

Do not assume both. The source separates adjustable variants by suffix. Confirm the selected release functions, pickup ranges and time-current curve.

Can one fault rating be used at both voltage options?

No universal rating is assigned. Confirm voltage-specific Icu / Ics for the capacity code and pole arrangement; the copied matrix has ambiguous row headings.

How should I choose 3P or 4P?

The summary lists both. Provide the circuit and neutral requirements, then confirm the switching arrangement and installation drawing for the chosen device.

Can I use the catalog dimensions for the final switchboard?

Use them only after matching the pole arrangement and suffix. Confirm mounting, terminals, clearances and any depth variants in the approved installation drawing.

What is needed for a WLM6RT-160 quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a WLM6RT-160 Adjustable MCCB Quotation

Tell W9 Group your selected current, release suffix, adjustment functions, poles, operating voltage, fault duty and panel arrangement, quantity and destination market so the selected configuration can be identified.

Contact W9 Group