• Воздушный выключатель WEW3-7500 acb с вынимаемым элементом заземления, стационарный тип, 1000 ВА/1500 ВА, 4000 А, 3 фазы, acb 4 фазы Галерея изображения 1
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4
  • Воздушный выключатель WEW3-7500 acb с вынимаемым элементом заземления, стационарный тип, 1000 ВА/1500 ВА, 4000 А, 3 фазы, acb 4 фазы Галерея изображения 1
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 2
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 3
  • Air circuit breaker WEW3-7500 acb withdrawable type acb fixed type 1000VAC/1500VAC 4000A 3p acb 4p acb Gallery image 4

Воздушный выключатель WEW3-7500

The WEW3-7500 air circuit breaker is listed by W9 Group with a 7500 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

WEW3-7500 3 Pole and 4 Pole Air Circuit Breaker Specifications

The WEW3-7500 air circuit breaker is listed by W9 Group with a 7500 A summary rating, 3P / 4P options and fixed or withdrawable configurations. Select the ordered current and controller, then obtain voltage-specific fault ratings and installation data for the exact capacity code.

WEW3 Air Circuit Breaker 7500
Максимальный рабочий ток (в А), 40°C 4000-5000-6300-7500
Определенная изоляционная напряженность Ui (В) 1000
Определенная импульсная прочность на напряжение (kV) 12
Определенная рабочая напряженность Ue(V), переменный ток 50/60 Гц 400 В/690 В
Используйте категорию B
Определенная рабочая напряженность Ue(V), переменный ток 50/60 Гц 100%In
Код прорыва пропускной способности M H
Число столбов 3P ■ ■
4P ■ ■
Определён как наилучший
прекращение замыкания
мощность ИКУ (кА)
AC380V/400V/415V 120 138
AC690V 85 105
AC800V/1140V – –
Сервис с рейтингом «нарушение»
мощность Ics (kA)
AC380V/400V/415V 100 138
AC690V 85 105
AC800V/1140V – –
Устойчивость при кратковременном напряжении 
ток Icw (кА/1с)
AC380V/400V/415V 100 138
AC690V 85 105
AC800V/1140V – –
Механический срок службы
(Ко второй переработке)
Поддержание работоспособности 16000
Электрическая жизнь
(Ко второй переработке)
AC415V,In 6000
AC690V,В 2000
Стандартная конфигурация Исправлено Drawetry-pe
Корпус выключателя ■ ■
Подложка для ящиков ■ ■
Интеллектуальный контроллер ■ ■
Верхние и нижние горизонтальные соединительные провода ■ ■
Указывает на контакт при открывании/закрывании ■ ■
Указывает на контакт с выключателем аварийного режима ■ ■
Помощный контакт 4NO+4NC ■ ■
Механизм управления электродвигателем ■ ■
Отключение шнура ■ ■
Дополнительные аксессуары
Фазовое разделение □ □
Обеспечение мгновенного отключения от электропитания при понижении напряжения □ □
Отключение при понижении напряжения □ □
Замок кнопки открытия и закрытия □ □
Замок для основания ящика □ □
Замок для положения отделения сиденья ящика □ □
Ключевой замок □ □
Интерлок для дверей □ □
Помощный контакт 6NO+6NC □ □
Электрические индикаторы трех позиций на основании ящика □ □
Интерлок стального кабеля □ □
Защелкивающий замок □ □
Двойной регулятор мощности □ □
Внешний нейтральный линейный трансформатор □ □
трансформатор с нулевым серией □ □
Поземный токоизмерительный трансформатор и его принадлежности □ □
Размер
Размер (мм)
Ш×В×Г
Ширина (3P/4P) 105/105 105/105
Высота 62/62 62/62
Глубина 61/61 61/61
Масса
Вес (кг)/Стабильный 3P 110/120/130
4P 140.3/151.2/162.3
Вес (кг)/корзина 3P 175/200/220
4P 175/200/220

ГИД ПО ОТБЕРЕЖЕ

How to Select a 7500A Fixed or Withdrawable Air Circuit Breaker

Specify the ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements when requesting a WEW3-7500 quotation from W9 Group.

01

Define the current and frame

State WEW3-7500, the ordered current and continuous load. Confirm the selected controller and any derating conditions.

02

Match the application voltage

Provide system voltage and prospective fault current. Request a matched rating table rather than relying on a generic solar application title.

03

Choose fixed or withdrawable

Confirm the construction, base, interlocks, terminal arrangement and maintenance access on the installation drawing.

04

Specify the control package

List required trip functions, operating supply, auxiliary feedback and communication needs. Confirm each item in the supplied bill of materials.

Before specifying WEW3-7500: Confirm the complete model, voltage, controller and fault-duty documentation. Series solar wording does not establish extended-voltage or outdoor suitability for the supplied breaker.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

WEW3-7500 ACB Wiring, Icu, Ics and Icw Document Requests

Use technical support and related products to specify WEW3-7500. Request a datasheet and wiring diagram matching the selected WEW3-7500 configuration.

Часто задаваемые вопросы покупателей

WEW3-7500 Air Circuit Breaker FAQs: Fault Ratings and Trip Controllers

Find answers about WEW3-7500 selection, configuration and ordering.

Which current choices are listed for WEW3-7500?

The target table lists 4000, 5000, 6300, 7500 A. Confirm the ordered current, controller range and any enclosure or temperature derating.

Does the listing establish every voltage mentioned in the old title?

Use a matched rating document for the offered device. The summary, title and some table entries differ; no extended-voltage suitability is promised from the title alone.

How do fixed and withdrawable versions differ for ordering?

State the required construction and confirm the supplied base, position indication, interlocks, terminals and installation dimensions for that version.

Сопоставимы ли значения Icu, Ics и Icw?

Request all required ratings separately at the project voltage. Confirm the short-time withstand duration and the controller settings used in the coordination study.

Does every controller include ground-fault protection or communication?

A series configuration list does not establish every controller function. Confirm the exact controller code, sensing arrangement, protection functions and communication interface.

Can the breaker be installed outdoors without an enclosure?

The available listing does not establish a complete outdoor enclosure specification. Confirm the switchboard protection, environmental conditions and installation requirements; generic waterproof wording is not a device rating.

What is needed for a WEW3-7500 quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a WEW3-7500 Air Circuit Breaker Quotation

Tell W9 Group your ordered current, poles, construction, system voltage, fault level, controller and control-supply requirements, quantity and destination market so the selected configuration can be identified.