Industrial Products

HomeProductsIndustrial ProductsMCCB Accessoriesmccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 1
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 2
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 3
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 4
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 5
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 6
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 1
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 2
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 3
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 4
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 5
  • mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial Gallery image 6

mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial

Looking for MCCB accessories? Get under voltage contact for AC230V AC380V DC240V and DC24V with wiring or terminal options. Find the best deals here

Function

Realize the under-voltage protection function of the circuit breaker, open the circuit breaker when the 
power supply voltage is too low, and protect the electrical equipment.
 When the supply voltage drops (even slowly) to 70% to 35% of the rated control supply voltaage, 
the under voltage, the undervoltage trips, the breaker should open the circuit breaker reliably.
 When the supply voltage is equal to or greater than 85% of the rated control supply voltage of the 
undervoltage release, the circuit breaker should be guaranteed to close.
 When the supply voltage is less than 35% of the rated control supply voltage of the undervoltage 
release, the undervoltage release should prevent the circuit breaker.

Model description

mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial detail image 1

Code for mccb Frame

Frame 125/160 250 400
code UVT-125 UVT-250 UVT-400

Electrical characteristics

 Ue(V) AC DC
230V  400V  110  220 24
ln(A)  0.3 0.3  0.15 0.15 0.15

Wiring diagram

mccb accessories Under voltage contact ac230V ac380V dc240v dc 24v with wiring or termial detail image 2