기술 데이터
WLPV-1085 photovoltaic fuse specifications
W9 Group lists the WLPV-1085 photovoltaic fuse with gPV operation class and a 1500VDC designation for photovoltaic DC protection. Select the individual fuse current, verify its time-current behavior and match the exact physical format to the holder before ordering.
| 모델 | WLPV-1085 |
|---|---|
| 제품 카테고리 | Photovoltaic fuse |
| 직류 전압 표기 | 1500VDC |
| 발행된 현재 범위 | 2A–32A |
| Published fuse size | 10×85 |
| Operation class | gPV |
| 기재된 파괴 용량 | 20kA |
| Standards listed | GB/T 13539.6 / IEC60269-6; confirm applicable documentation |
선정 가이드
WLPV-1085 solar DC fuse selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a WLPV-1085 quotation from W9 Group.
광전 회로를 연결하세요.
최대 DC 시스템 전압, 어레이 구성 및 가능한 고장전류 발생원을 제공하십시오. 정확한 보호 지점에 대한 퓨즈 용량을 확인하십시오.
현재 및 곡선을 선택하세요.
모듈 및 회로의 요구사항을 주문한 퓨즈의 정격전류와 시간-전류 곡선과 비교하십시오. 설치 조건에 따른 전류 저하 정보를 요청하십시오.
퓨즈와 퓨즈 홀더의 장착 상태를 점검하십시오.
퓨즈의 정확한 치수, 접점 배열 및 홀더 정격을 확인하십시오. 주문 전에 제공되는 부품과 포함된 구성 요소를 반드시 확인하십시오.
중단 조건을 확인하십시오.
DC 차단 조건, 동작 곡선 및 관련 기술 문서를 요청하십시오. 전체 조립품에 대한 모든 절연 및 교체 절차를 확인하십시오.
W9 그룹 소개
W9 Group support for WLPV-1085 photovoltaic fuse
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLPV-1085 enquiry, contact W9 Group about configuration and matching product documents.

관련 자료
WLPV-1085 Photovoltaic Fuse Dimensions and Datasheets
Use technical support and related products to specify WLPV-1085. Request a datasheet and wiring diagram matching the selected WLPV-1085 configuration.
구매자 FAQ
WLPV-1085 gPV fuse selection FAQs
Find answers about WLPV-1085 selection, configuration and ordering.
What does the gPV designation mean for selection?
The supplier lists gPV as the fuse operation class for photovoltaic protection. Confirm the exact time-current curve, DC operating conditions and scope for the offered fuse; the class label does not select the current for the circuit.
Which voltage and current range are listed?
The target description lists 1500VDC and 2A–32A. Confirm the individual current option and the conditions associated with the DC voltage designation.
Which fuse holder fits this model?
The source lists the 10×85 format. Confirm the dimensioned drawing, end contacts and holder compatibility for the exact supplied version.
Does the 20kA figure apply under every circuit condition?
The supplier lists 20kA breaking capacity. Confirm the corresponding DC voltage and test conditions, and compare them with the prospective fault current at the protection point.
Can I replace it with an AC fuse of the same current?
Do not select by current alone. Confirm a photovoltaic DC rating, operating curve, physical format and holder compatibility appropriate to the exact circuit.
Can a fuse be reset after operation?
A fuse link is replaced after operation rather than reset like a circuit breaker. Confirm the cause of operation and use the specified isolation and replacement procedure for the installation.
What is needed for a WLPV-1085 quotation?
필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.
제품 문의
Request a WLPV-1085 photovoltaic fuse quotation
W9 Group에 주문번호, 회로 사용 목적, 설치 조건 및 필요한 서류, 수량 및 판매처를 알려주시면 선택된 구성이 확인될 수 있습니다.