산업용 제품

홈제품산업용 제품MCCBMCCB M7 시리즈WLM7DCWLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 1
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 2
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 3
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 4
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 5
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 6
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 1
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 2
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 3
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 4
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 5
  • WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break Gallery image 6

WLM7DC-800A-2300 2Poles 3Poles WLM7DC Series 1500vdc Photovoltaic solar type Molded Case Circuit Breakers 250vdc/500vdc/750VDC/1000VDC/1500VDC 800A Photovoltaic DC circuit break

Rated Current : 800A Number Of Poles : 2P/3P Rated Working Voltage : 800V

MCCB Highlights

1. With overload and short circuit protection functions
2. It can protect lines and power equipment from damage
3. It has the characteristics of small size, high breaking capacity, short flying tiger, good anti vibration, etc,DC MCCBs are designed to offer high breaking capacity, allowing them to interrupt fault currents and protect the electrical system from damage. The ability to handle high fault currents is crucial in DC applications, where the consequences of a fault can be more severe compared to AC systems. By incorporating MCCBs with high breaking capacity, the overall reliability and safety of the DC system are significantly enhanced.
The high breaking capacity of MCCBs also ensures that they can effectively protect sensitive equipment and components within the DC circuit. This is particularly important in applications where the interruption of power supply due to a fault can lead to costly downtime and potential damage to critical assets.

Main performance index of WLM7DC  series circuit breaker

WLM7DC Moulded Case Circuit Breaker 800
Rated operating current In (A),40℃ 630-700-800
Rated insulation voltage Ui (V) 1500
Rated impulse withstand voltage (kV) 12
Rated operational voltage Ue(V),AC 50/60Hz 750/1000/1200/1500
Breaking capacity code – M H
Number of poles 2P – ■ ■
3P – ■ ■
DC250V – 25 50
DC500V – 25 50
Rated ultimate
short-circuit breaking
capacity Icu(kA)
DC750V – 15 25
DC1000V – 15(3P30) 25(3P40)
DC1250V – – –
DC1500V – 10(3P25) 20(3P30)
Rated service breaking
capacity Ics(kA)
DC250V – 25 50
DC500V – 25 50
DC750V – 15 25
DC1000V – 15 25
DC1250V – – –
DC1500V – 10 25(3P30)
Standard
Utilization category A
Ambient temperature
Safety of insulation ■
Arcing distance 0
Mechanical life
(CO recycle)
Maintenance free 15000
Electrical life
(CO recycle)
Maintenance free 2000(DC1500V is :1000times)
Release units
Distribution protection TM ■
Mounting and connection
Fixed Front connection ■
Rear connection ■
Plug-in Front connection ■
Rear connection ■
Draw-out Front connection –
Rear connection –
DIN rail Front connection –
Dimension
Dimension (mm)
W×H×D
Width 130/182
Height 270
Depth 154.5
Weight
Weight(kg)/Fixed 2P 6.2
3P 8.5
4P –

Overall and installation dimensions of circuit breaker