CSDM7-800H-3300 전자기 MCCB
기술 데이터
CSDM7-800H-3300 Electronic MCCB: 800 A, 3P and LSIG Release Selection
CSDM7-800H-3300 전자식 MCCB는 LSIG 보호 등급을 갖춘 W9 그룹 800 A, 3P 몰드 케이스 회로 차단기입니다. 제품 요약에는 380V/690V가 기재되어 있습니다. 배전반에 사용할 공급 전자식 트립 장치, 설정 범위 및 지락 감지 방식을 명시하십시오. 설치를 조정하기 전에 전압별 Icu와 Ics를 요청하십시오.
| 제품 모델 | CSDM7-800H-3300 |
|---|---|
| 제품 카테고리 | 전자형 케이스형 회로 차단기 |
| 정격 전류 명칭 | 800 A |
| 폴란드 배열 | 3P |
| 작동 전압 표기 | 380V/690V |
| Protection designation | LSIG |
| Release settings | Confirm the exact release code, pickup ranges, delays and time-current curves |
| Ground-fault arrangement | Request sensing, neutral treatment and any external sensor requirements |
| 차단 용량 | Request voltage-specific Icu and Ics |
선정 가이드
How to Select CSDM7-800H-3300 Electronic MCCB LSIG Settings and Fault Ratings
Specify the full order code, poles, operating voltage, fault duty, LSIG settings and sensing arrangement when requesting a CSDM7-800H-3300 quotation from W9 Group.
Specify the complete LSIG release
Request the supplied long-time, short-time, instantaneous and ground-fault functions, pickup settings and delay ranges. Confirm the release code before selecting a coordination curve.
Match poles and ground-fault sensing
Confirm the 3P terminal arrangement, neutral treatment and the required sensing scheme. Request any external sensor details for the actual supply system.
Coordinate voltage and fault duty
Provide the operating voltage, prospective short-circuit current and adjacent protective devices. Request Icu and Ics for the exact release and breaker configuration.
Define control and installation needs
Request mounting, terminal and accessory drawings. Confirm display, communication, auxiliary supply and powered operating mechanisms separately if required.
W9 그룹 소개
W9 Group CSDM7-800H-3300 Electronic Molded Case Circuit Breaker Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a CSDM7-800H-3300 enquiry, contact W9 Group about configuration and matching product documents.

관련 자료
CSDM7-800H-3300 Electronic MCCB Wiring, Trip Curves and Ground-Fault Documents
Use technical support and related products to specify CSDM7-800H-3300. Request a datasheet and wiring diagram matching the selected CSDM7-800H-3300 configuration.
구매자 FAQ
CSDM7-800H-3300 Electronic MCCB FAQs: LSIG, Ground Fault and Selectivity
Find answers about CSDM7-800H-3300 selection, configuration and ordering.
Which configuration is listed for CSDM7-800H-3300?
W9 Group identifies 800 A, 3P, 380V/690V and an electronic LSIG designation. Confirm the full order code and supplied release.
What does LSIG mean for this electronic MCCB?
LSIG describes long-time, short-time, instantaneous and ground-fault protection. Confirm the actual function availability, setting ranges, delays and sensing requirements of the offered release.
How should the electronic trip settings be selected?
Use the load profile and protection-coordination study with the exact release curves. Request the setting increments and supported function combinations rather than deriving a range from the model number.
Does ground-fault protection provide sensitive earth-leakage protection?
Confirm the ground-fault sensing method, pickup and trip time. LSIG ground-fault protection alone does not establish a particular residual-current sensitivity or suitability for personnel protection.
Does the H or L code establish breaking capacity?
Request numerical Icu and Ics at the actual operating voltage and configuration. A model capacity letter does not establish a complete rating schedule or prove selectivity with another breaker.
Are display, communication and remote operation included?
Confirm display functions, protocol, auxiliary supply and operating accessories separately. An electronic release does not by itself establish an LCD, network interface or powered remote closing.
What is needed for a CSDM7-800H-3300 quotation?
필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.
제품 문의
Request a CSDM7-800H-3300 Electronic MCCB Quotation
Tell W9 Group your full order code, poles, operating voltage, fault duty, LSIG settings and sensing arrangement, quantity and destination market so the selected configuration can be identified.






































