산업용 제품

  • DC6 맥스비어 액세서리 모터 구동기 DC24V 110VDC 220V AC 400V 갤러리 이미지 1
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 2
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 3
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 4
  • DC6 맥스비어 액세서리 모터 구동기 DC24V 110VDC 220V AC 400V 갤러리 이미지 1
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 2
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 3
  • DC6 mccb accessories motor drive DC24V 110VDC 220V AC 400V Gallery image 4

DC6 MCCB 모터 구동

The DC6 MCCB motor drive is a motor operating mechanism offered by W9 Group for compatible molded case circuit breakers. Specify the host breaker, exact control supply and opening, closing and reset sequence when selecting the mechanism for remote operation. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

DC6 MCCB Motor Drive for Remote Opening and Closing

The DC6 MCCB motor drive is a motor operating mechanism offered by W9 Group for compatible molded case circuit breakers. Specify the host breaker, exact control supply and opening, closing and reset sequence when selecting the mechanism for remote operation.

Model/type 125/160/250/400/630/800/1250/2000
Ue AC230V, 400V, DC24V
Hz 50HZ
제품 모델 DC6 -160 DC6 -250 DC6 -400 DC6 -800 DC6 -2000
 Size  A  110 140  177   174   174
 H  62 59  61   78   78
 W  90 105  140   210   210

선정 가이드

How to Select a DC6 MCCB Motor Operating Mechanism and Supply

Specify the host breaker code, frame, mounting interface, control supply, command scheme and required feedback when requesting a DC6 quotation from W9 Group.

01

Match the host breaker

Provide the complete breaker code, frame, pole arrangement and mounting interface. Request written confirmation of the matching mechanism.

02

Select the control supply

Specify the actual control circuit voltage and AC or DC type. Confirm the mechanism nameplate and allowable supply limits.

03

Define command and interlock logic

Request opening, closing and reset wiring. Confirm command duration, trip lockout and any closing-permission interlocks.

04

Check panel access and feedback

Confirm installed dimensions, manual operation access and the required position feedback for the complete assembly.

Before specifying DC6: Confirm the ordered mechanism and host together. Voltage choices and frame lists do not establish universal compatibility or an automatic transfer function.

W9 그룹 소개

W9 Group DC6 MCCB Motor Drive Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a DC6 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

DC6 MCCB Motor Drive Wiring, Reset and Interlock Documents

Use technical support and related products to specify DC6. Request a datasheet and wiring diagram matching the selected DC6 configuration.

구매자 FAQ

DC6 MCCB Motor Drive FAQs: Control Voltage and Breaker Compatibility

Find answers about DC6 selection, configuration and ordering.

What is the DC6 MCCB motor drive used for?

The target description identifies remote opening, closing and re-opening of a compatible circuit breaker. Confirm the host and trip/reset sequence for the ordered mechanism.

Which control voltage should I order?

The title and electrical table list different supply options. Confirm the nameplate voltage, AC or DC type, frequency and operating limits for the ordered DC6; no all-voltage mechanism is implied.

Will this mechanism fit any MCCB with the same current rating?

Confirm the exact breaker series, frame, release, mounting interface and mechanism code. A matching current designation does not establish mechanical compatibility.

Does it replace the breaker protection release?

Do not substitute a motor operating mechanism for the required protection release. Confirm the complete breaker and control scheme, including how protective trips affect closing permission.

Can I use a pulse or maintained command?

The DC6 source mentions pulse and self-holding control. Confirm the permitted command duration, interlocks and reset logic in the supplied wiring instructions.

What should be checked for manual operation and status feedback?

Request the manual/automatic selection instructions, state indication, feedback contacts and maintenance procedure for the matched host assembly. Confirm which feedback parts are included.

What is needed for a DC6 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a DC6 MCCB Motor Drive Quotation

Tell W9 Group your host breaker code, frame, mounting interface, control supply, command scheme and required feedback, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기