MCB JCB3-80Hで電気安全性を向上
JCB3-80H specification matrix
| フィールド | Reviewed listing | Confirm for the order |
|---|---|---|
| Current | 1–80 A | Exact step and code |
| Breaking rating | 10 kA version | Voltage and applicable declaration |
| カーブ | B/C/D | Corresponding time-current curve |
| ポーランド人 | Single through four-pole options | Actual neutral and phase arrangement |
| 保護 | 過負荷および短絡 | Separate residual-current requirements |
| Proposed use | Main check |
|---|---|
| モーター部門 | Starting envelope and curve |
| Distribution board | Terminals and assembly acceptance |
| 故障レベルが高い | Applicable interruption rating |
| Electronic equipment | Any required RCD arrangement |
レビューを 小型遮断器のラインナップ 負荷負荷量、ポール配置、および障害レベル調査に基づいて。.

Check the JCB3-80H rating against the board
W9’s current listing identifies 1–80 A options, B/C/D curves and a 10 kA version. Compare the applicable rating at the actual voltage with the prospective 短絡電流. Do not assume a higher headline kA value makes the device a universal replacement for another MCB.
The exact pole arrangement, terminal system, busbar geometry and assembly requirements must also fit. Select the curve using starting behaviour and fault-disconnection calculations. If the circuit requires 残留電流保護, the MCB label does not supply it.
現代の急速な世界では、電気システムの安全性と信頼性を確保することが不可欠です。家庭用設備や産業用電力配電システムにおいて、MCB(機械式遮断器)は重要な役割を果たします。 JCB3-80H 小型遮断器は信頼性があり効率的なソリューションです。短絡および過負荷保護機能と最大10kAの断面積を備えたこの遮断器は、安心感を提供し、電気機器を潜在的な危険から保護するように設計されています。.
MCB JCB3-80Hは、1Aから80Aの幅広い電流範囲を備え、幅広い用途に適しています。1ポインツ、2ポインツ、3ポインツ、および4ポインツのオプションにより、多種多様な設置ニーズに対応する汎用性がさらに強化されています。さらに、B、C、またはDのカーブオプションは、特定の要件に基づいてカスタマイズが可能で、さまざまな電気環境において最適な性能を発揮します。この柔軟性により、MCB JCB3-80Hは幅広い電気設置用途に最適な多用途かつ適応性の高い選択肢となります。.
国際基準への準拠はあらゆる電気部品の重要な要素であり、MCB JCB3-80Hはこの点において卓越しています。この製品はIEC 60898-1規格に準拠しており、厳しい電気安全性能基準を満たしています。この認証はMCB JCB3-80Hの信頼性と品質を裏付け、電気システムの効果的な保護能力に対する信頼性を保証します。.
MCB JCB3-80H miniature circuit breaker is a robust and reliable solution for ensuring electrical safety in a wide range of applications. Its comprehensive features, including short-circuit and overload protection, high 破壊能力, contact indicators, and compliance with international standards, make it ideal for domestic, commercial, and industrial installations. With its versatility, reliability, and unwavering adherence to stringent standards, the MCB JCB3-80H fully embodies our commitment to electrical safety and performance.
よくある質問
Does JCB3-80H include earth-leakage detection?
Its listed MCB functions are overload and short circuit. Provide the required residual-current arrangement separately.
Is the listed 10 kA value enough for every board?
No. Confirm its voltage and applicable product declaration, then compare with the installation fault level and any approved backup arrangement.
Can I change the curve to prevent a motor-start trip?
Only after reviewing starting current, conductors and fault-disconnection requirements. A higher pickup threshold can change protection performance.
What should be checked before replacing another MCB?
Verify ratings, curve, poles, terminals, busbars and assembly acceptance. Matching rail mounting and amperes is insufficient.
参考文献
MCBの注文コードを確認するには、, W9グループへのお問い合わせ 曲線、電流、電圧、極、および 将来的な故障電流.