サーキット保護製品

  • ミニチュア遮断器 JCB3-80M 6kA ギャラリー画像 1
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 12
  • ミニチュア遮断器 JCB3-80M 6kA ギャラリー画像 1
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80M 6kA Gallery image 12

JCB3-80M MCB

JCB3-80M MCBは、過負荷および短絡保護用の小型回路ブレーカーです。W9グループでは、1~80 Aの定格電流と6 kAの遮断容量をラインアップしており、1P/2P/3P/4Pの構成も用意しています。回路および盤の配置に応じて、定格電流、極数、トリップ特性曲線をお選びください。選択した構成と対応する技術資料は、W9グループまでお問い合わせください。.

技術データ

JCB3-80M 6kA ミニチュア回路ブレーカーの仕様

JCB3-80M MCBは、過負荷および短絡保護用の小型回路遮断器です。W9グループでは、1~80 Aの定格電流と6 kAの遮断容量をラインアップしており、1P/2P/3P/4Pの構成が可能です。回路および基板の配置に応じて、電流値、極数、トリップ特性を選択してください。.

スタンダード IEC/ EN 60898- 1  IEC/ EN 60947- 2
電気機能 定格電流 In (A) 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
ポーランド人 1P、1P+ N、2P、3P、3P+ N、4P 1P、2P、3P、4P
定格電圧 Ue(V) 230/ 400~ 240/ 415
絶縁耐電圧 Ui (V) 500
定格周波数 50/60Hz
定格断面積 6kA
エネルギー制限クラス 3
Rated impulse withstand voltage( 1. 2/ 50) Uimp ( V) 4000
Dielectric test voltage at ind. Freq. for 1 min ( kV) 2
汚染度 2
Power  loss  per pole Rated  current  ( A)
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
Thermo- magnetic release characteristic B, C, D 8- 12In, 9. 6- 14. 4In
Mechanicalfe atures 電気寿命 4,000
機械的寿命 20,000
接触位置インジケーター はい
保護レベル IP 20
サーマルエレメントの設定時の基準温度(℃) 30
Ambient temperature ( with daily average ≤35℃) – 5…+40 ℃
保管温度(℃) -25…+ 70 ℃
インストール ターミナル接続タイプ Cable/ U- type busbar/ Pin- type busbar
Terminal size top/ bottom for cable 25mm2 / 18- 4 AWG
Terminal size top/ bottom for busbar 10mm2 / 18- 8 AWG
締めトルク 2. 5 N* m / 22 In- Ibs.
取り付け On DIN rail EN 60715 ( 35mm) by means of fast clip device
接続 From  top  and bottom
Combination withaccessori es 補助連絡先 はい
シュントの放出 はい
電圧降下時の放電 はい
アラームコンタクト はい

選定ガイド

How to Select a 1 Pole to 4 Pole MCB

Specify the rated current, pole count, trip curve, operating voltage and board connection details when requesting a JCB3-80M quotation from W9 Group.

01

Match current to the circuit

The catalog covers 1–80 A. Confirm the required current step and coordinate it with the circuit conductors and load.

02

Choose the trip curve

The reviewed matching features list B / C / D. Request the selected time-current curve for starting-current and coordination checks.

03

Specify poles and supply

State the supply voltage and required 1P / 2P / 3P / 4P arrangement. Confirm the wiring diagram and terminal allocation.

04

Check the board space

Request dimensions and busbar details for the selected pole version before finalizing the board.

Before specifying JCB3-80M: Confirm the ordered current, pole configuration, operating voltage and trip curve. Use the matching model datasheet for installation and fault-duty checks.

W9 GROUPについて

W9 Group MCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB3-80M enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JCB3-80M MCB Datasheet and Trip Curve Information

Use W9 Group technical support and the product directory to specify JCB3-80M. Request a datasheet and wiring diagram matching the selected JCB3-80M configuration.

購入者のよくある質問

JCB3-80M MCB FAQs: Pole Options and Short-Circuit Rating

Find answers about JCB3-80M selection, configuration and ordering.

What does JCB3-80M protect against?

The product is listed for overload and short-circuit protection. Residual-current protection requires a suitable additional device or an RCBO configuration.

Which currents are listed for JCB3-80M?

The target-model summary lists a 1–80 A range. Confirm the individual current rating and complete order code.

Which pole configurations are offered?

This page lists 1P / 2P / 3P / 4P. Confirm the wiring and neutral arrangement in the matching product drawing.

How do I specify the trip curve?

The matching features list B / C / D. Select using the load starting current and protective coordination, and request the corresponding curve.

Is the listed 6kA rating suitable for every board?

The breaking rating must meet the prospective short-circuit current at the installation point. Confirm the applicable voltage and rating on the supplied datasheet.

How is this MCB installed?

The source lists 35 mm DIN-rail mounting. Confirm the terminal capacity, busbar type, dimensions and tightening instructions for the ordered version.

What is needed for a JCB3-80M quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a JCB3-80M MCB Quotation

Tell W9 Group your rated current, pole count, trip curve, operating voltage and board connection details, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ