サーキット保護製品

ホーム製品サーキット保護製品RCBOResidual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 1
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 2
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 3
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 1
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 2
  • Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA Gallery image 3

Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA

The JCB2LE-4E RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential housesElectronic TypeResidual current (rcd) protectionOverload and short circuit protectionBreaking capacity 6kARated current up to 80A (available from 6A to 80A)Available in B or C tripping curvesType A or Type AC are availableTripping sensitivity: 30mA,100mA,300mAComplies with IEC 61009-1, EN61009-1

Introduction

JCB2LE-80M4P RCBO combines RCD and MCB protection in a 4 module wide device and is operating for unbalanced loads and balanced loads, 3 phase protection in DIN rail distribution box.

JCB2LE-80M4P RCBO (Residual Current Circuit Breaker with Overload Protection) provides residual and overload protection in one neat device. The breaking capacity is up to 6kA. The rate current is up to 80Amps. It is available in 6A, 10A, 16A, 20A, 32A, 40A, 50A, 63A,80A. It is available in A type and AC type. Type AC RCBOs are used for general purpose on AC (Alternating Current) only circuits. Type A are used for DC (Direct Current) protection. Available in 30mA,100mA,300mA tripping sensitivity. Available in B, C ,D tripping curves.

JCB2LE-80M4P RCBO is commonly used in applications where there is the need to combine protection against overcurrents (overload and short-circuit) and protection against earth leakage currents. They help in sensing this kind of faults and trip the circuit ensuring complete protection of the people and connected equipment

JCB2LE-80M4P RCBO is purposed to protect one from the risk of electrical shocks, firesand electrocution. It can also assist in sudden earth faults. The installation of an JCB2LE-80M4P RCBO ensures that a circuit trips immediately and protects you from electric shock.

JCB2L3-80M4P comply with IEC 61009-1, EN61009-1 standard.

Product Description

Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 1

Main Features

● Electronic 4-pole
● Leakage Protection
● Overload and short circuit protection
● Non-linear/load sensitive
● Breaking capacity up to 6kA
● Rated current up to 80A (available in 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A, 80A)
● Provide B-type and C-type tripping curves
● Trip sensitivity: 30mA, 100mA, 300mA
● Type A or AC available
● Insulated openings facilitate busbar installation
● 35mm DIN rail mounting
● Compatible with many types of combination head screwdrivers
● Meet ESV’s additional testing and verification requirements for RCBO
● Comply with IEC 61009-1, EN61009-1
The electronic 4-pole RCBO offers comprehensive functionality to ensure strong electrical protection. It features leakage protection, overload and short-circuit protection, and non-linearity/load sensitivity designed to protect against a wide range of electrical faults. Breaking capabilities up to 6kA and current ratings up to 80A (available in various amperages) make them suitable for a variety of applications.
RCBO has B-type and C-type tripping curves to choose from, and the tripping sensitivity has three options: 30mA, 100mA, and 300mA, which can meet different requirements. Additionally, it offers the flexibility of Type A or AC configurations to meet specific circuit needs.
The design includes insulated openings for easy busbar installation and 35mm DIN rail mounting, ensuring easy and safe installation. In addition, it is compatible with many types of double-ended screwdrivers, simplifying maintenance and upkeep.
The device meets ESV’s additional testing and validation requirements for RCBOs to ensure compliance with industry standards, including IEC 61009-1 and EN61009-1, providing safety and performance assurance.

Technical Data

● Standard: IEC 61009-1, EN61009-1
● Type: Electronic
● Type (detected leakage waveform): A or AC available
● Number of poles: 4 poles
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A
● Rated working voltage: 400V, 415V AC
● Rated sensitivity I△n: 30mA, 100mA, 300mA
● Rated breaking capacity: 6kA
● Insulation voltage: 500V
● Rated frequency: 50/60Hz
● Rated impulse withstand voltage (1.2/50): 6kV
● Pollution level: 2
● Thermomagnetic release characteristics: B curve, C curve, D curve
● Mechanical life: 10,000 times
● Electrical life: 2000 times
● Protection level: IP20
● Ambient temperature (daily average ≤35℃): -5℃~+40℃
● Contact position indicator: green = closed, red = open
● Terminal connection type: cable/U-shaped busbar/pin busbar
● Installation: Mounting on DIN rail EN 60715 (35mm) via quick clamp device
● Recommended torque: 2.5Nm
● Connection method: can be connected from the top or bottom
Electronic RCBOs are designed to comply with a comprehensive set of technical specifications to ensure reliable and safe operation in a variety of electrical installations. It complies with IEC 61009-1 and EN61009-1 standards and complies with international safety and performance standards.
The 4-pole RCBO has a rated current range from 6A to 80A and is suitable for rated operating voltages from 400V to 415V AC. It offers rated sensitivity options of 30mA, 100mA and 300mA to ensure effective protection against ground leakage currents.
The RCBO has a rated breaking capacity of 6kA, an insulation voltage of 500V and is designed to withstand electrical stresses and impulses. Pollution level 2, suitable for use in various environments.
The device is equipped with thermomagnetic release characteristics in B-curve, C-curve and D-curve options, providing flexibility to meet specific application requirements. The mechanical life span reaches 10,000 times and the electrical life span reaches 2,000 times, ensuring long-term reliability.
The RCBO has an IP20 protection rating, which provides adequate protection against solid objects but limited protection against water intrusion. Its designed working environment temperature range is -5℃ to +40℃, suitable for a variety of working conditions.
RCBO is available in a variety of terminal connection types, including cable, U-busbar and pin-type busbar, and can be mounted on DIN rail EN 60715 (35mm) using quick-clamp devices. The recommended installation torque is 2.5Nm, and it can be flexibly connected from the top or bottom for easy installation and maintenance.

Standard

IEC61009-1 ,  EN61009-1

Electrical

features

Rated current In (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Type

Eletronic

Type (wave form of the earth leakage sensed)

A or AC are available

Poles

4 Pole

Rated voltage Ue(V)

230/240

Rated sensitivity I△n

30mA,100mA,300mA

Insulation voltage Ui (V)

500

Rated frequency

50/60Hz

Rated breaking capacity

6kA

Rated impulse withstand voltage(1.2/50) Uimp (V)

6000

Pollution degree

2

Thermo-magnetic release characteristic

B, C

Mechanical

features

Electrical life

2, 000

Mechanical life

10, 000

Contact position indicator

Yes

Protection degree

IP20

Reference temperature for setting of thermal element(℃)

30

Ambient temperature (with daily average ≤35℃)

-5…+40

Storage temperation (℃)

-25…+70

Installation

Terminal connection type

Cable/U-type busbar/Pin-type busbar

Terminal size top/bottom for cable

25mm2  / 18-4 AWG

Terminal size top/bottom for Busbar

10mm2  / 18-8 AWG

Tightening torque

2.5 N*m  /  22 In-Ibs.

Mounting

On DIN rail EN 60715 (35mm) by means of fast clip device

Connection

From top

Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 2

Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 3

Respect the environment – ​​comply with EU directives:
In addition to complying with Directive 2002/95/EC of January 27, 2003 (known as “RoHS”), this directive restricts the use of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated compounds. Phenyl ether (PBDE) brominated flame retardants, our commitment to environmental responsibility extends to compliance with Directive 91/338/EEC of 18 June 1991 and Decree No. 94-647 of 27 June 2007.

We ensure that our MCCB production lines comply with these directives, demonstrating our commitment to sustainable and environmentally friendly manufacturing practices. By complying with these regulations, we contribute to protecting the environment and the health and safety of our customers and communities. Our commitment to environmental compliance is evident in every aspect of our production process, from material sourcing to manufacturing and distribution.