محصولات صنعتی

خانهمحصولاتمحصولات صنعتیMCCBMCCB M7 SeriesWLM7DCWLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 1
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 2
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 3
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 1
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 2
  • WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb Gallery image 3

WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb

Rated Current : 400A Number Of Poles : 2P Rated Working Voltage : 800V

MCCB Highlights

WLM7DC MCCB: Application field of centralized inverter: PV string is output to DC combiner box for confluence, and then DC/AC inverter is used for inversion. After AC output, the voltage is boosted and connected to the grid. DC combiner box and DC side of inverter shall be equipped with DC circuit breaker, with working voltage of DC1000V → DC1500V.

Remote Monitoring and Communication Capabilities
In the era of smart and connected systems, the ability to remotely monitor and communicate with electrical components is becoming increasingly important. DC MCCBs are equipped with advanced communication capabilities, allowing for remote monitoring of their status, trip events, and operational parameters. This level of connectivity enables proactive maintenance and troubleshooting, leading to improved system reliability and reduced downtime.
Furthermore, remote communication capabilities also facilitate integration with supervisory control and data acquisition (SCADA) systems, allowing for centralized monitoring and control of DC MCCBs across multiple locations. This level of integration enhances the overall visibility and management of the electrical infrastructure, contributing to improved operational efficiency and maintenance practices.

Main performance index of WLM7DC  series circuit breaker

WLM7DC Moulded Case Circuit Breaker 400Q
Rated operating current In (A),40℃ 250-280-315-320-350-400
Rated insulation voltage Ui (V) 1500
Rated impulse withstand voltage (kV) 12
Rated operational voltage Ue(V),AC 50/60Hz 110/250/500/750/1000/1200/1500
Breaking capacity code – M H
Number of poles 2P – – ■
3P – – ■
DC250V – – 50
DC500V – – 50
Rated ultimate
short-circuit breaking
capacity Icu(kA)
DC750V – – 25
DC1000V – – 25(3P40)
DC1250V – – –
DC1500V – – 10(3P30)
Rated service breaking
capacity Ics(kA)
DC250V – – 50
DC500V – – 50
DC750V – – 25
DC1000V – – 25(3P40)
DC1250V – – –
DC1500V – – 10(3P30)
Standard
Utilization category A
Ambient temperature
Safety of insulation ■
Arcing distance 0
Mechanical life
(CO recycle)
Maintenance free 20000
Electrical life
(CO recycle)
Maintenance free 2000(DC1500V is :1000times)
Release units
Distribution protection TM ■
Mounting and connection
Fixed Front connection ■
Rear connection ■
Plug-in Front connection ■
Rear connection ■
Draw-out Front connection –
Rear connection –
DIN rail Front connection ■
Dimension
Dimension (mm)
W×H×D
Width 130/182
Height 270
Depth 125.8
Weight
Weight(kg)/Fixed 2P 2.5
3P 3.2
4P –

Overall and installation dimensions of circuit breaker

WLM7DC-400A-2300 2Poles WLM7DC Series Photovoltaic solar type dc mccb 250vdc/500vdc/750VDC/1000VDC/1500VDC 250A 3 Poles solar mccb detail image 1