Productos industriales

InicioProductosProductos industrialesMCCBSerie M6WLM6EMCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles
  • Disjuntor MCCB WLM6E-2000A-3300 de 3 polos/4 polos Serie WLM6E Disjuntor electrónico MCCB 2000A 400V/690V 3 polos/4 polos Imagen de galería 1
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 2
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 3
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 4
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 5
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 6
  • Disjuntor MCCB WLM6E-2000A-3300 de 3 polos/4 polos Serie WLM6E Disjuntor electrónico MCCB 2000A 400V/690V 3 polos/4 polos Imagen de galería 1
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 2
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 3
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 4
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 5
  • MCCB circuit breaker WLM6E-2000A-3300 3P/4P WLM6E Series MCCB 2000A electronic circuit breaker 400V/690V 3 Poles/4 Poles Gallery image 6

Disjuntor MCCB WLM6E-2000A-3300 de 3 polos/4 polos Serie WLM6E Disjuntor electrónico MCCB 2000A de 400V/690V de 3 polos/4 polos

The WLM6E 2000A electronic MCCB is listed by W9 Group for the configuration described below. Confirm the selected current, poles, supply voltage and trip-unit version against the matching order-code datasheet.

DATOS TÉCNICOS

WLM6E 2000A Electronic MCCB Specifications

The WLM6E 2000A electronic MCCB is listed by W9 Group for the configuration described below. Confirm the selected current, poles, supply voltage and trip-unit version against the matching order-code datasheet.

WLM6E Moulded Case Circuit Breaker 2000
Corriente de operación nominal en (A), 40 °C 6 adjutable knobs 500-630-700-800-1000-1250-1500-1600
3 adjutable knobs 500-630-700-800-1000-1250-1500-1600
Características eléctricas
Tensión de aislamiento nominal Ui (V) 1000
Tensión de resistencia a la impulsión nominal (kV) 8
Tensión operativa nominal Ue(V), CA 50/60Hz 380/400/415,440,500,660/690
Código de capacidad de ruptura C S M H
Número de postes 1P – – – –
2P – – – –
3P – – ■ ■
4P – – ■ ■
Número de postes CA220/230/240V – – – –
CA380/400/415V – – 70 100
AC440V – – 20 20
AC500V – – – –
AC660/690V – – 20 20
Número de postes CA220/230/240V – – – –
CA380/400/415V – – 50 70
AC440V – – – –
AC500V – – – –
AC660/690V – – 10 10
Estándar
Categoría de utilización B
Temperatura ambiente
Seguridad de la aislación ■
Distancia de arco 0
Vida mecánica
(Reciclaje de CO)
Mantenimiento 2500
Vida eléctrica
(Reciclaje de CO)
AC415V,En 500
AC690V,En 400
Unidades de liberación
Protección de la distribución E ■
Protección del motor E ■
Instalación y conexión
Corregido Conexión frontal ■
Conexión trasera –
Pluggable Conexión frontal –
Conexión trasera –
Desarrollar Conexión frontal ■
Conexión trasera ■
Rápidamente montable en un panel de pared Conexión frontal –
Dimension
Dimensiones (mm)
W×H×D
Ancho (3P/4P) 210/280
Altura 340
Profundidad 141
Peso
Protección de la distribución 1P –
2P –
3P 16.8/17.1/18.82
4P 21.86/23.24/24.54

Guía de selección

Selecting a 2000A Electronic MCCB with 3P or 4P Options

Specify the required 2000 A configuration, pole arrangement, supply voltage, short-circuit duty, trip-unit settings and installation requirements when requesting a WLM6E quotation from W9 Group.

01

Especifica el voltaje y los polos actuales

Use WLM6E 2000 A in the enquiry and state the required 3P or 4P arrangement. Confirm the rated current and full order code on the quotation.

02

Compruebe el estado de funcionamiento de la carga en la tensión de alimentación

Indique la tensión de suministro y la corriente de cortocircuito potencial. Solicite el código de la capacidad seleccionada y sus valores máximos y de ruptura de servicio.

03

Combine la unidad de viaje

Request the fitted electronic trip-unit functions, setting schedule and coordination curves. Confirm any ground-fault or communication options separately.

04

Verificación de la integración del panel

Request a dimension drawing for the selected WLM6E 2000 A pole and trip-unit configuration. Do not plan the enclosure from the series name alone.

Before specifying WLM6E: Confirm the selected WLM6E 2000 A rating label, voltage-specific breaking capacity, trip settings and installation drawing before ordering. The catalog page does not by itself identify a complete order configuration.

QUÉ ES W9 GROUP

W9 Group 2000A Electronic MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6E order, contact W9 Group about the required configuration and product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

WLM6E 2000A MCCB Datasheet and Wiring Diagram Requests

Use W9 Group’s MCCB guide and product directory for context. Request a datasheet and wiring diagram matching the selected WLM6E configuration.

Preguntas frecuentes del comprador

WLM6E 2000A MCCB FAQs: Trip Unit, Ratings and Panel Fit

Encuentre respuestas sobre las calificaciones, la configuración de la unidad de viaje y los documentos de instalación.

What configuration does the WLM6E 2000 A page list?

The catalog lists a 2000 A current designation, 3P or 4P options and working voltages of 400 V and 690 V. Confirm the exact configuration and its marked ratings before ordering.

How should I specify the WLM6E trip unit?

Consulte el documento del modelo correspondiente.

How can I verify the WLM6E 2000 A panel dimensions?

Consulte el documento del modelo correspondiente.

What is needed for a WLM6E quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. El precio, la cantidad mínima de pedido, la disponibilidad de muestras y el plazo de entrega no se publican para este producto; confirme estos datos con W9 Group.

How do I choose the breaking capacity for the WLM6E 2000A MCCB?

Provide the installation voltage and prospective short-circuit current. Request the Icu and Ics data for the exact WLM6E 2000A capacity code; confirm the rating at that voltage rather than using a value from a different condition.

Which WLM6E 2000A electronic trip settings should I specify?

Request the protection-function list, adjustment schedule and time-current curves for the installed WLM6E 2000A release. Confirm the available settings on the quoted trip unit rather than inferring them from the frame designation.

Does the WLM6E 2000A electronic MCCB include display or communication functions?

Ask W9 Group to confirm the supplied WLM6E 2000A trip-unit interface and any separately ordered functions. Request the matching function list and wiring documents; the electronic designation alone does not establish a display or communication option.

Solicitud de producto

Request a WLM6E 2000A Electronic MCCB Quotation

Tell W9 Group your required 2000 A configuration, pole arrangement, supply voltage, short-circuit duty, trip-unit settings and installation requirements, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group