W9 Group lists the WLPV-1085 photovoltaic fuse with gPV operation class and a 1500VDC designation for photovoltaic DC protection. Select the individual fuse current, verify its time-current behavior and match the exact physical format to the holder before ordering.

DATOS TÉCNICOS

WLPV-1085 photovoltaic fuse specifications

W9 Group lists the WLPV-1085 photovoltaic fuse with gPV operation class and a 1500VDC designation for photovoltaic DC protection. Select the individual fuse current, verify its time-current behavior and match the exact physical format to the holder before ordering.

WLPV-1085 product specifications
Modelo WLPV-1085
Categoría de producto Fusible fotovoltaico
DC voltage designation 1500VDC
Rango actual publicado 2A–32A
Published fuse size 10×85
Operation class gPV
Capacidad de ruptura indicada 20kA
Standards listed GB/T 13539.6 / IEC60269-6; confirm applicable documentation

Guía de selección

WLPV-1085 solar DC fuse selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a WLPV-1085 quotation from W9 Group.

01

Empareja el circuito fotovoltaico.

Proporcione el voltaje máximo del sistema de corriente continua, la configuración del arreglo fotovoltaico y las posibles fuentes de corriente de falla. Confirme la clasificación de la protección por fusible para el punto de protección específico.

02

Seleccione la corriente y la curva

Compare los requisitos del módulo y del circuito con la corriente nominal del fusible y la curva tiempo-corriente. Solicite información sobre la reducción de carga dependiente de la instalación.

03

Verifique el ajuste del fusible y del portafusibles.

Asegúrese de que las dimensiones del fusible, la disposición de los contactos y la clasificación del portafusibles coincidan exactamente. Confirme el componente ofrecido y los accesorios incluidos antes de realizar el pedido.

04

Verifique las condiciones de interrupción

Solicite las condiciones de corte en corriente continua, la curva de funcionamiento y los documentos técnicos correspondientes. Confirme cualquier procedimiento de aislamiento y sustitución para el conjunto completo.

Before specifying WLPV-1085: Confirme la corriente nominal, la tensión de CC, la curva de funcionamiento, el formato físico exacto y el soporte compatible antes de realizar la selección.

QUÉ ES W9 GROUP

W9 Group support for WLPV-1085 photovoltaic fuse

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLPV-1085 enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

WLPV-1085 Photovoltaic Fuse Dimensions and Datasheets

Use technical support and related products to specify WLPV-1085. Request a datasheet and wiring diagram matching the selected WLPV-1085 configuration.

Preguntas frecuentes del comprador

WLPV-1085 gPV fuse selection FAQs

Find answers about WLPV-1085 selection, configuration and ordering.

What does the gPV designation mean for selection?

The supplier lists gPV as the fuse operation class for photovoltaic protection. Confirm the exact time-current curve, DC operating conditions and scope for the offered fuse; the class label does not select the current for the circuit.

Which voltage and current range are listed?

The target description lists 1500VDC and 2A–32A. Confirm the individual current option and the conditions associated with the DC voltage designation.

Which fuse holder fits this model?

The source lists the 10×85 format. Confirm the dimensioned drawing, end contacts and holder compatibility for the exact supplied version.

Does the 20kA figure apply under every circuit condition?

The supplier lists 20kA breaking capacity. Confirm the corresponding DC voltage and test conditions, and compare them with the prospective fault current at the protection point.

Can I replace it with an AC fuse of the same current?

Do not select by current alone. Confirm a photovoltaic DC rating, operating curve, physical format and holder compatibility appropriate to the exact circuit.

Can a fuse be reset after operation?

A fuse link is replaced after operation rather than reset like a circuit breaker. Confirm the cause of operation and use the specified isolation and replacement procedure for the installation.

What is needed for a WLPV-1085 quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

Solicitud de producto

Request a WLPV-1085 photovoltaic fuse quotation

Informe a W9 Group del código completo de su pedido, la función del circuito, las condiciones de instalación y los documentos requeridos, la cantidad y el mercado de destino para que pueda identificarse la configuración seleccionada.

Contacte a W9 Group