フューズ

ホーム製品フューズWLPV-1038 太陽光発電用ヒューズ

WLPV-1038 光起電 fuse

W9 Group lists the WLPV-1038 photovoltaic fuse with gPV operation class and a 1000VDC designation for photovoltaic DC protection. Select the individual fuse current, verify its time-current behavior and match the exact physical format to the holder before ordering.

技術データ

WLPV-1038 photovoltaic fuse specifications

W9 Group lists the WLPV-1038 photovoltaic fuse with gPV operation class and a 1000VDC designation for photovoltaic DC protection. Select the individual fuse current, verify its time-current behavior and match the exact physical format to the holder before ordering.

WLPV-1038 product specifications
モデル WLPV-1038
製品カテゴリー 太陽光発電用ヒューズ
直流電圧の表示 1000VDC
公開されている現在の範囲 2A–32A
Published fuse size 10x38mm
Operation class gPV
リストされたブレーク容量 20kA
Standards listed GB/T 13539.6 / IEC60269-6; confirm applicable documentation

選定ガイド

WLPV-1038 solar DC fuse selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a WLPV-1038 quotation from W9 Group.

01

太陽光発電回路を一致させる

最大直流系統電圧、アレイの配置および考えられる故障電流源を記載してください。具体的な保護ポイントにおけるヒューズの定格を確認してください。.

02

現在値とカーブを選択

モジュールおよび回路の要求事項と、発注済みヒューズの定格電流および時限特性曲線を比較してください。設置条件に応じたデレーティング情報については、別途お問い合わせください。.

03

ヒューズとホルダーの適合を確認してください。

ヒューズの寸法、接点配置およびホルダー定格を必ず一致させてください。ご注文の前に、提供される部品と付属品をご確認ください。.

04

割り込み条件を確認する

DC遮断条件、動作曲線および関連技術資料を要求してください。組立全体に関する隔離および交換手順を確認してください。.

Before specifying WLPV-1038: Confirm the ordered current, DC voltage, operating curve, exact physical format and compatible holder before selection.

W9 GROUPについて

W9 Group support for WLPV-1038 photovoltaic fuse

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLPV-1038 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

WLPV-1038 Photovoltaic Fuse Dimensions and Datasheets

Use technical support and related products to specify WLPV-1038. Request a datasheet and wiring diagram matching the selected WLPV-1038 configuration.

購入者のよくある質問

WLPV-1038 gPV fuse selection FAQs

Find answers about WLPV-1038 selection, configuration and ordering.

What does the gPV designation mean for selection?

The supplier lists gPV as the fuse operation class for photovoltaic protection. Confirm the exact time-current curve, DC operating conditions and scope for the offered fuse; the class label does not select the current for the circuit.

Which voltage and current range are listed?

The target description lists 1000VDC and 2A–32A. Confirm the individual current option and the conditions associated with the DC voltage designation.

Which fuse holder fits this model?

The source lists the 10x38mm format. Confirm the dimensioned drawing, end contacts and holder compatibility for the exact supplied version.

Does the 20kA figure apply under every circuit condition?

The supplier lists 20kA breaking capacity. Confirm the corresponding DC voltage and test conditions, and compare them with the prospective fault current at the protection point.

Can I replace it with an AC fuse of the same current?

Do not select by current alone. Confirm a photovoltaic DC rating, operating curve, physical format and holder compatibility appropriate to the exact circuit.

Can a fuse be reset after operation?

A fuse link is replaced after operation rather than reset like a circuit breaker. Confirm the cause of operation and use the specified isolation and replacement procedure for the installation.

What is needed for a WLPV-1038 quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

製品のお問い合わせ

Request a WLPV-1038 photovoltaic fuse quotation

W9 Group にご注文の全コード、回路の仕様、設置条件、必要な書類、数量、および配送先市場を伝えてください。そうすれば、選択された構成が特定できます。.

W9グループへのお問い合わせ