ホームブログ多用途で信頼性の高い JCB3-80M 小型遮断器

多用途で信頼性の高い JCB3-80M 小型遮断器

Release Time: 2026-02-22

説明は B、C、Dの曲線 磁気式プルアップを過熱保護動作から分離します。.

JCB3-80M selection matrix

フィールド Reviewed listing Acceptance check
Current 1–80 A options Exact ordered rating and conductors
Breaking rating 6 kA Applicable voltage and fault level
カーブ B/C/D options Actual time-current curve
ポーランド人 Multiple configurations Switched and protected paths
取り付け DINレール Board and busbar compatibility
Circuit condition Selection input
Motor or transformer starting Current-time envelope
Long cable run Minimum available fault current
Hot enclosure Manufacturer derating
Required additional protection Separate residual-current arrangement

The MCB保護ガイド 過電流保護の限界と、補完的な機能の必要性について説明しています。.

Reference illustration: JCB3-80M selection matrix

Reading the JCB3-80M configuration

The current listing identifies 1–80 A options and a 6 kA breaking rating, with B/C/D curve choices and several pole arrangements. Use the supplied model’s time-current curve and voltage-specific data for acceptance. Alternative standard columns in a web table do not establish identical declarations for every version.

Review conductor ampacity and starting current before choosing the curve. Verify terminal and busbar compatibility for the actual distribution board; fitting onto a DIN rail does not prove that the assembled board is approved. Separate 残留電流保護 remains necessary where required by the installation rules.

The JCB3-80M’s 6 kA label is useful only when it meets the 将来的な故障電流 at the installation point. Current, trip curve, poles and board fit still need to be selected for the individual circuit.

One of the key features of the JCB3-80M miniature circuit breaker is its contact indicator, which enhances ease of monitoring and maintenance. The indicator provides visual cues to quickly and efficiently identify any potential issues, minimizing downtime and ensuring continuous operation of the electrical system.

In addition to the contact indicators, the JCB3-80M miniature circuit breaker offers flexibility through its availability in various configurations. Available in current ranges from 1A to 80A, the circuit breakers are available in 1, 2, 3 and 4 pole options and can be customized to meet the specific requirements of different applications. In addition, the choice of B, C or D curves provides further customization to precisely fit the unique needs of different electrical systems.

Importantly, the JCB3-80M miniature circuit breaker complies with the international standard IEC 60898-1, ensuring its reliability and compliance with industry regulations. This adherence to standards emphasizes product quality and reliability, giving both users and installers peace of mind.

Whether for residential, commercial or industrial use, the JCB3-80M miniature circuit breaker provides a reliable and adaptable solution for protecting electrical systems. Its combination of reliability, flexibility and compliance with international standards make it a valuable asset in ensuring the safety and efficiency of electrical installations.

In summary, the JCB3-80M miniature circuit breaker is a versatile and reliable choice for protection in a variety of environments. With its high 破壊能力, contact indication and flexibility in configurations and curves, it provides a comprehensive solution for ensuring the safety and reliability of electrical systems. Compliance with international standards further enhances its quality and reliability, making it an essential component in any electrical installation.

よくある質問

What does JCB3-80M protect against?

Its listed functions are overload and 短絡保護. Required residual-current protection must be provided separately or by a suitable combined device.

Is 6 kA suitable for every installation?

No. Compare the prospective fault current with the applicable rating at the circuit voltage. Any backup arrangement needs documented coordination.

Are B, C and D curves interchangeable?

No. They have different magnetic pickup characteristics. Select using load starting current and the required fault-disconnection performance.

Does DIN-rail mounting establish board compatibility?

No. Check terminals, busbars, clearances and the assembly manufacturer’s requirements as well as mechanical mounting.

参考文献

MCBの注文コードを確認するには、, W9グループへのお問い合わせ with the curve, current, voltage, poles and prospective fault current.