JC3AE 2 Module 1P+N Arc fault Detection Device (AFDD+RCBO)
Description
JC3AE AFDD consists of a Type A RCBO and a Arc fault detection module in a single module DIN rail mounted unit. They combine short circuit, overload, over voltage, earth leakage protection and arc fault protection and will disconnect Live and Neutral poles in the event of these faults. It could avoid various of fires caused by short circuit, circuit aging, heavy load, poor contact, fault electrical devices etc. Automatic control is realized by built-in computer chip. Its operating principle: the detected arc impulse is processed, compared and identified by electronic circuit and MCU. Once fault arc impulse which easily creates fire detected, the output will drive tripping unit to cut off the load power supply, so that the fire is prevented.
Protective Area
JC3AE AFDDs combines AFDD, MCB and A type RCD devices.They can detect & respond as for type AC, PLUS pulsating DC components. This allows to provide the highest protection level. Ideal for Domestic and Commercial applications
Overvoltage Protection
Overvoltage condition of 270Vrms to 300Vrms for 10 seconds will cause device to trip. LED indication of over-voltage trip will be provided on product re-latch.
BI-Directional
JC3AE is a bi-directional AFDD, which is suitable for PV and EV systems
Series & Parallel Arc Fault
JC3AE is designed to activate and shut off power when it detects both series and parallel arc faults, preventing potential fire hazards
اطلاعنامه
JC3AE AFDD is designed for use in single phase AC current systems in either single phase only units or on one phase of a 3 phase distribution unit at a rated Voltage of 230V @ 50Hz. The JC3AE must not be used in DC networks.
JC3AE Devices combine the function of a residual current operated device for earth leak detection, overcurrent protection for short-circuit and Arc fault detection for both parallel and series arcs. The device is intended to reduce the risk of fires by ignition from electrical sources.
مشخصات
| کد محصول | نوع | Curve | Amps | Rated residual operating current(IΔn) |
|---|---|---|---|---|
| JC3AE | AC, A, | B curve,C curve | 6A,10A,16A, 20A, 25A, 32A,40A,50A,63A | 30mA، 100mA، 300mA |
| Category | Item | Specification |
|---|---|---|
| ویژگیهای الکتریکی | استاندارد | IEC/EN 61009-1 & IEC/EN 62606 |
| Type (wave form of the earth leakage sensed) | A | |
| خاصیت آزاد شدن ترمو-مغناطیسی | B، C | |
| پال | 1P+N (Switched Live and Neutral) | |
| مقاومت جریان ورودی (A) | 6, 10, 16, 20, 25, 32, 40, 50, 63 | |
| ولتاژ رتبهدهی شده Ue (V) | 230 | |
| Rated sensitivity IΔn (A) | 0.03 | |
| Rated residual making and breaking capacity IΔm (A) | 3000 | |
| Rated short-circuit capacity Icn (A) | 6,000 | |
| Break time under IΔn (s) | ≤0.1 | |
| Rated frequency (Hz) | 50/60 | |
| Rated impulse withstand voltage (1.2/50)Uimp (V) | 4,000 | |
| Dielectric TEST voltage at ind. Freq. for 1min (kV) | 2 | |
| ولتاژ عایق بندی Ui (V) | 500 | |
| سطح آلودگی | 2 | |
| ویژگیهای مکانیکی | زندگی الکتریکی | 2,000 |
| زمان کارکرد مکانیکی | 2,000 | |
| نمایشگر موقعیت تماس | بله | |
| سطح حفاظت | IP20 | |
| Ambient temperature (with daily average≤35°C) | -5… +40 °C | |
| دمای ذخیره سازی | -25…+70 °C | |
| ارائه نصب | نوع اتصال ترمینال | کابل/پیوستهای U-type/پیوستهای Pin-type |
| Terminal size top for cable | 10mm² | |
| Terminal size bottom for cable | 16 mm² | |
| 18-5 AWG | ||
| Terminal size bottom for busbar | 10 mm² | |
| 18-8 AWG | ||
| تنگ کردن گشتاور | 2.5 N*m / 22 In-lbs. | |
| قرارگیری | On DIN rail EN 60715 (35mm) by means of fast clip device | |
| اتصال | from top and bottom |
Dimensions