Productos industriales

  • Disyuntor MCCB WLM6LY-400A-4300 tipo de protección contra fugas de tierra de la serie WLM6L 4P, RCCB 400V 400 amperios, 3 polos, 4 polos
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 6
  • Disyuntor MCCB WLM6LY-400A-4300 tipo de protección contra fugas de tierra de la serie WLM6L 4P, RCCB 400V 400 amperios, 3 polos, 4 polos
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 2
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 3
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 4
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 5
  • MCCB circuit breaker WLM6LY-400A-4300 4P WLM6L Series earth leakage protection type RCCB 400V 400amper 3 poles 4 Poles Gallery image 6

MCCB de fuga de tierra WLM6LY-400

The WLM6LY-400 earth leakage MCCB is listed by W9 Group with a 400 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version. Request the selected configuration and matching technical documents from W9 Group.

DATOS TÉCNICOS

WLM6LY-400 Earth Leakage MCCB Specifications

The WLM6LY-400 earth leakage MCCB is listed by W9 Group with a 400 A summary rating and 3P / 4P options. Its table identifies a thermal overcurrent release and an electronic leakage release. Specify the required residual-current response, pole arrangement and fault duty for the exact supplied version.

WLM6LY Moulded Case Circuit Breaker 400
Corriente nominal (A) del interruptor automático a 40 °C Tipo de arreglo 250-315-350-400
Tipo de LCD 250-315-350-400
Tensión de aislamiento nominal Ui (V) 1000
Tensión de resistencia a la impulsión nominal (kV) 8
Tensión operativa nominal Ue(V), CA 50/60Hz AC400V
Código de capacidad de ruptura C S M H
Número de postes 2P – – – –
3P – – ■ ■
4P – – ■ ■
Calificado como el mejor
Desconexión por cortocircuito
Capacidad de la unidad de control (kA)
CA380/400/415V – – 50 65
CA380/400/415V – – 35 42
Capacidad nominal de cierre y apertura en condiciones de fallo
Yo△ m(kA)
CA220/230/240V – – – 16.5
Límite del tiempo de no actuación Δt (ms) 0.06s/0.2s/0.5s/1s
Función de alarma de fuga sin disparo □
tipo de disparo por sobrecorriente Tipo térmico
Tipo de disparo por fuga Tipo electrónico
Tipo de corriente residual AC
Estándar IEC/EN 60947-2
Categoría de utilización A
Temperatura ambiente -40℃ ~+70 ℃
Seguridad de la aislación ■
Distancia de arco 0
Vida mecánica
(Reciclaje de CO)
Mantenimiento 15000
Vida eléctrica
(Reciclaje de CO)
AC415V,En 8000
AC690V,En 2000
Unidades de liberación
Instalación y conexión
Corregido Conexión frontal ■
Conexión trasera ■
Pluggable Conexión frontal ■
Conexión trasera ■
Desarrollar Conexión frontal –
Conexión trasera –
Rápidamente montable en un panel de pared Conexión frontal ■
Dimension
Dimensiones (mm)
W×H×D
Anchura (2P/3P/4P) -/140/184
Altura 257
Profundidad 103
Peso
Protección de la distribución 2P –
3P 4.758
4P 6.314

Guía de selección

Selecting a 400A Earth Leakage MCCB by Sensitivity and Poles

Specify the selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode when requesting a WLM6LY-400 quotation from W9 Group.

01

Choose the ordered current

The 400 A page lists 250, 315, 350, 400 A. Confirm the selected current and full model suffix, including the pole arrangement.

02

Specify leakage protection

Provide the required sensitivity, waveform response and delay. Confirm the actual available settings; residual-current making capacity is not the sensitivity setting.

03

Check voltage and fault duty

Use the selected configuration’s operational-voltage and breaking-capacity data. Confirm the capacity code and do not substitute insulation voltage for operating voltage.

04

Define alarm, mounting and wiring

Confirm tripping versus alarm-only behavior, mounting form, neutral routing and the connection drawing. Request the required test and commissioning instructions.

Before specifying WLM6LY-400: Confirm current, poles, residual-current sensitivity and delay, alarm / trip mode, operating voltage and voltage-specific fault ratings. The source mixes generic RCCB prose and configuration data; do not treat the prose as a complete order specification.

QUÉ ES W9 GROUP

W9 Group 400A Earth Leakage MCCB Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a WLM6LY-400 enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

WLM6LY-400 Residual-Current MCCB Datasheet and Wiring Requests

Use technical support and related products to specify WLM6LY-400. Request a datasheet and wiring diagram matching the selected WLM6LY-400 configuration.

Preguntas frecuentes del comprador

WLM6LY-400 Earth Leakage MCCB FAQs: Sensitivity, Alarm and Fault Duty

Find answers about WLM6LY-400 selection, configuration and ordering.

Which current choices are listed for WLM6LY-400?

The summary identifies 400 A. The frame schedule lists 250, 315, 350, 400 A. Confirm the selected current and complete order code; the schedule is not a guaranteed adjustment range.

¿Es este un interruptor diferencial sin protección contra sobrecorriente?

La tabla de referencia describe un dispositivo en caja moldeada con disparadores de sobrecorriente y de fuga. Confirme las funciones completas de protección en la hoja de datos correspondiente; el texto genérico sobre RCCB no es suficiente para clasificar la unidad solicitada.

What leakage sensitivity can I order?

A definitive sensitivity schedule is not established by the available page. State your required residual-current pickup and delay, then confirm the available combination with W9 Group.

Does the listed residual-current type cover every waveform?

The table lists AC residual-current response. Confirm the expected leakage waveform and required device type; do not assume support for other waveforms from the electronic release description.

Can the breaker signal leakage without tripping?

A leakage-alarm non-tripping function is marked as an option. Confirm whether it is available, which mode is supplied and how the alarm is wired for the exact order code.

How should I select voltage and breaking capacity?

Request the operational-voltage and Icu / Ics data for the pole arrangement and capacity code. Confirm discrepancies between the summary and table before installation; no universal fault rating is assigned here.

What is needed for a WLM6LY-400 quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

Solicitud de producto

Request a WLM6LY-400 Earth Leakage MCCB Quotation

Tell W9 Group your selected current, poles, leakage sensitivity and delay, waveform requirement, voltage, fault duty and alarm mode, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group