Productos de protección de circuitos

InicioProductosProductos de protección de circuitosMCBJCB3-63DC Disjuntor de circuito miniatura de CC
  • JCB3-63DC Interruptor de circuito miniatura de polaridad DC (MCB)
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 2
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 3
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 4
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 5
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 6
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 7
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 8
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 9
  • JCB3-63DC右侧面4p.png
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 11
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 12
  • JCB3-63DC Interruptor de circuito miniatura de polaridad DC (MCB)
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 2
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 3
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 4
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 5
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 6
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 7
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 8
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 9
  • JCB3-63DC右侧面4p.png
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 11
  • JCB3-63DC Polarity DC Miniature Circuit Breaker (MCB) Gallery image 12

JCB3-63DC Disjuntor de circuito miniatura de CC

El interruptor automático en miniatura de corriente continua JCB3-63DC está homologado por W9 Group para la protección contra sobrecargas y cortocircuitos en circuitos de corriente continua. La tabla de selección ofrece opciones de intensidad desde 6 A hasta 63 A, curvas de disparo B/C y versiones de 1P/2P/3P/4P. Confirme la polaridad, la conexión de polos y la capacidad de interrupción específica para el voltaje correspondiente en la instalación real. Solicite la configuración seleccionada y los documentos técnicos correspondientes a W9 Group.

DATOS TÉCNICOS

JCB3-63DC DC Miniature Circuit Breaker: Current, Poles and Trip Curves

The JCB3-63DC DC miniature circuit breaker is listed by W9 Group for overload and short-circuit protection in direct-current circuits. The target table lists current choices from 6 A to 63 A, B / C trip curves and 1P / 2P / 3P / 4P versions. Confirm polarity, pole wiring and voltage-specific fault duty for the actual installation.

Código del producto JCB3-63DC
Pola 1 Pole 2 Pole 3 Pole 4 Pole
Estándar IEC/ EN  60947- 2
 

 

 

 

Electrical  features

Rated  current  In   (A) 6 ,  10,  16, 20 , 25 , 32, 40, 50 , 63
Rated  voltage  Ue(V) 1P:DC250V,  2P:DC500V,  3P:DC 750V, 4P:DC1000V
Insulation  voltage  Ui   (V) 1000V
Rated impulse withstand voltage Uimp (V) 4000V
Rated  breaking  capacity 6 kA
Rated  impulse  withstand  voltage( 1 . 2/ 50)  Uimp   (V) 4000
Pollution  degree 2
Thermo- magnetic  release  characteristic B  Curve ,  C  Curve
 

 

 

Mechanicalfeatures

Electrical  life ≥1500
Mechanical  life ≥20000
Contact  position  indicator Sí
Protection  degree IP 20
Reference  temperature  for  setting  of  thermal  element(℃) 30
Ambient  temperature   (with  daily  average   ≤35℃) – 5…+40 ℃
Storage  temperation   (℃) -25 . . . + 70 ℃
 

 

Instalación

Terminal  connection type Cable/ U-type  busbar/ Pin-type  busbar
Terminal  size top/ bottom for  cable 25mm2    / 18-4  AWG
Terminal  size top/ bottom  for busbar 10mm2   /  18- 8 AWG
Tightening  torque 2. 5  N*m    /   22  In-Ibs.
Instalación On  DIN  rail  EN  60715  ( 35mm)
 

Combination with accessories

Auxiliary  contact Sí
Shunt  release Sí
Under  voltage  release Sí
Alarm  contact Sí

Guía de selección

How to Select a JCB3-63DC DC MCB by Pole Voltage and Polarity

Specify the current, trip curve, DC voltage, pole wiring, polarity, fault level and accessory requirements when requesting a JCB3-63DC quotation from W9 Group.

01

Select the DC current and curve

Use the table current choices and confirm the selected B or C curve against load startup and protection coordination.

02

Match voltage and pole wiring

Select the pole arrangement for the system voltage and obtain the required series connection and earthing diagram.

03

Confirm polarity and reverse current

The title and body give inconsistent polarity descriptions. Request the exact terminal marking and allowed current direction for the supplied version.

04

Check fault duty and accessories

Confirm DC fault capacity, circuit time constant where applicable, installation conditions and each ordered accessory code.

Before specifying JCB3-63DC: Confirm polarity and standard references using the supplied version documents. Pole-dependent voltage ratings do not justify arbitrary wiring or unrestricted bidirectional operation.

QUÉ ES W9 GROUP

W9 Group JCB3-63DC DC Circuit Breaker Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB3-63DC enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

JCB3-63DC DC MCB Wiring, Polarity and Fault-Rating Document Requests

Use technical support and related products to specify JCB3-63DC. Request a datasheet and wiring diagram matching the selected JCB3-63DC configuration.

Preguntas frecuentes del comprador

JCB3-63DC DC MCB FAQs: Pole Wiring, DC Voltage and Breaking Capacity

Find answers about JCB3-63DC selection, configuration and ordering.

Which currents are listed for JCB3-63DC?

The electrical table lists 6, 10, 16, 20, 25, 32, 40, 50 and 63 A. The prose mentions a broader lower-end range; use a confirmed order schedule for any additional current.

Does every pole version have the highest DC voltage rating?

No. The table assigns different DC voltages to different pole arrangements. Confirm the required pole connection and operating voltage for the selected version.

Is JCB3-63DC polarity sensitive?

The native title calls it polarity DC while body prose says it is not polarity sensitive. Confirm the actual terminal markings, wiring diagram and permitted current direction before installation.

What does the listed breaking capacity establish?

The table lists 6 kA. Confirm the applicable DC voltage, pole arrangement, test conditions and project fault duty for the ordered breaker.

Does the DC breaker replace residual-current or insulation monitoring?

Do not infer those functions from overload and short-circuit protection. Confirm any additional monitoring or protection required by the system design.

Which standard and accessories should be specified?

The summary and body use different standard references. Request the exact-model test documents and confirm each auxiliary contact, alarm or release by its matching accessory code.

What is needed for a JCB3-63DC quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

Solicitud de producto

Request a JCB3-63DC DC Miniature Circuit Breaker Quotation

Tell W9 Group your current, trip curve, DC voltage, pole wiring, polarity, fault level and accessory requirements, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group