{"id":2150,"date":"2026-07-30T11:25:58","date_gmt":"2026-07-30T03:25:58","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1-1\/"},"modified":"2026-07-30T11:26:02","modified_gmt":"2026-07-30T03:26:02","slug":"jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1-1","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ru\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1-1-1-1\/","title":{"rendered":"RCBO JCB1LE-125 125A 6kA"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>The JCB1LE-125 RCBOs (residual current circuit breaker with overload protection) are suitable for distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.<\/p>\n<p>They are suitable for AC 50Hz, single phase, 3 phase, rated current from 63A to 125A circuit.<br \/>They prevent earth leakage, direct or indirect contact electric shock and other faults, and are applicable to low-voltage terminal power distribution in such fields as industry, civil construction, energy, communication and infrastructure. They provide short-circuit protection, overload protection, leakage protection and isolation protection.<\/p>\n<p>When personal electric shock or grid leakage, When the current exceeds the specified value, JCB1LE-125 RCBO will be quickly cut off the faulty power supply in a very short time to protect the safety of people and electrical equipment. At the same time, it can protect the line from overload or short-circuit, and it can also be used as an infrequent conversion of the line.<\/p>\n<p>Combination of ELCB &amp; MCB (EL+MCB) offers 3 in 1 protection against -overload, short circuit and earth leakage<\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-01-6.webp\" alt=\"RCBO JCB1LE-125 125A 6kA detail image 1\" loading=\"lazy\"><\/p>\n<p>Main Features<\/p>\n<p>\u25cf Electronic type: JCB1LE-125 RCBO is designed with electronic components to ensure reliable and precise operation.<\/p>\n<p>\u25cf Leakage protection: These RCBOs have the function of preventing leakage, which enhances the safety of the electrical system.<br \/>\n\u25cf Overload and short-circuit protection: RCBO provides comprehensive protection against overload and short-circuit conditions, protecting equipment and personnel.<br \/>\n\u25cf Non-Line\/Load Sensitive: RCBO is designed to be insensitive to line\/load conditions, ensuring consistent performance in a variety of electrical configurations.<br \/>\n\u25cf Breaking capacity: RCBO has a breaking capacity of up to 6kA, which can effectively break fault current and minimize potential damage to the electrical system.<br \/>\n\u25cf Rated current: Provides a variety of rated currents from 63A to 125A to meet different power load requirements.<br \/>\n\u25cf Trip curve: Type B and C trip curves are provided to provide flexible response characteristics for different applications.<br \/>\n\u25cf Trip sensitivity: RCBO offers 30mA, 100mA and 300mA trip sensitivity options for precise response to fault conditions.<br \/>\n\u25cf Type A or AC: Customers can choose between Type A or AC configurations to meet specific application needs.<br \/>\n\u25cf Insulating openings: RCBO has insulating openings to facilitate busbar installation and simplify the installation process.<br \/>\n\u25cf DIN rail installation: Designed for 35mm DIN rail installation, ensuring compatibility with standard mounting systems.<br \/>\n\u25cf Screwdriver compatibility: Compatible with a variety of combination head screwdrivers for easy installation and maintenance.<br \/>\n\u25cf Compliance: RCBO meets ESV additional testing and verification requirements to ensure compliance with industry standards for safety and performance. They also comply with IEC 61009-1 and EN61009-1 standards, providing quality and reliability assurance.<\/p>\n<p>\nTechnical Data<\/p>\n<p>\u25cf Standard: JCB1LE-125 RCBO complies with IEC 61009-1 and EN61009-1 standards to ensure compliance with industry safety and performance requirements.<br \/>\n\u25cf Type: This RCBO is electronic and uses advanced electronic components to work reliably and accurately.<br \/>\n\u25cf Type (detected leakage waveform): Customers can choose Type A or Type AC configurations to meet specific application needs, providing flexibility in leakage detection.<br \/>\n\u25cf Number of poles: Available in 1-pole, 2-pole, 3-pole and 4-pole configurations, suitable for various electrical system settings.<br \/>\n\u25cf Rated current: There are four rated currents: 63A, 80A, 100A, and 125A to meet different electrical load requirements.<br \/>\n\u25cf Rated working voltage: The rated working voltage of RCBO is AC 400V and 415V, ensuring compatibility with standard electrical systems.<br \/>\n\u25cf Rated sensitivity I\u25b3n: Provides 30mA, 100mA, and 300mA rated sensitivity options to accurately respond to fault conditions.<br \/>\n\u25cf Rated breaking capacity: The rated breaking capacity of RCBO is 6kA, which can effectively break fault current and minimize potential damage to the electrical system.<br \/>\n\u25cf Insulation voltage: RCBO insulation voltage is 500V, ensuring safe and reliable operation in various electrical environments.<br \/>\n\u25cf Rated frequency: The rated frequency is 50\/60Hz, ensuring compatibility with standard power systems.<br \/>\n\u25cf Rated impulse withstand voltage (1.2\/50): The rated impulse withstand voltage of RCBO is 6kV, which has strong protection against transient voltage surges.<br \/>\n\u25cf Pollution level: The pollution level is Level 2, suitable for use in moderately polluted environments.<br \/>\n\u25cf Thermal magnetic release characteristics: It has B-curve, C-curve and D-curve characteristics and can flexibly respond to overcurrent conditions.<br \/>\n\u25cf Mechanical life: The mechanical life is designed to be 10,000 times to ensure long-term reliability and durability.<br \/>\n\u25cf Electrical Life: These RCBOs have an electrical life of 2000 cycles, providing consistent performance over a long service life.<br \/>\n\u25cf Protection level: The protection level is IP20, which means it can protect solid objects larger than 12mm without harmful effects.<br \/>\n\u25cf Ambient temperature: Suitable for operation at ambient temperatures from -5\u00b0C to +40\u00b0C, with the daily average temperature not exceeding 35\u00b0C.<br \/>\n\u25cf Contact position indicator: Equipped with contact position indicator, green indicates OFF and red indicates ON, providing intuitive status indication.<br \/>\n\u25cf Terminal connection type: Compatible with cable or pin busbar connections, providing flexibility in installation options.<br \/>\n\u25cf Installation: Designed to be installed on DIN rail EN 60715 (35mm) using a quick clamp device to ensure simple and safe installation.<br \/>\n\u25cf Recommended torque: The recommended torque for terminal connection is 2.5Nm to ensure correct and firm connection.<br \/>\n\u25cf Connection method: Flexible connection from top or bottom for easy installation and maintenance.<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\n<p>Standard<\/p>\n<\/td>\n<td>\n<p>IEC61009-1 , \u00a0EN61009-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p>Electrical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Rated current In (A)<\/p>\n<\/td>\n<td>\n<p>63,80,100,125<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type<\/p>\n<\/td>\n<td>\n<p>Electronic<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type (wave form of the earth leakage sensed)<\/p>\n<\/td>\n<td>\n<p>A or AC are available<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Poles<\/p>\n<\/td>\n<td>\n<p>1 pole, 2 Pole, 3 pole, 4 pole<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated voltage Ue(V)<\/p>\n<\/td>\n<td>\n<p>230\/240<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated sensitivity I\u25b3n<\/p>\n<\/td>\n<td>\n<p>30mA,100mA,300mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation voltage Ui (V)<\/p>\n<\/td>\n<td>\n<p>500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated breaking capacity<\/p>\n<\/td>\n<td>\n<p>6kA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated impulse withstand voltage(1.2\/50) Uimp (V)<\/p>\n<\/td>\n<td>\n<p>6000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pollution degree<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Thermo-magnetic release characteristic<\/p>\n<\/td>\n<td>\n<p>B, C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p>Mechanical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Electrical life<\/p>\n<\/td>\n<td>\n<p>2, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mechanical life<\/p>\n<\/td>\n<td>\n<p>2, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Contact position indicator<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection degree<\/p>\n<\/td>\n<td>\n<p>IP20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reference temperature for setting of thermal element(\u2103)<\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ambient temperature (with daily average \u226435\u2103)<\/p>\n<\/td>\n<td>\n<p>-5&#8230;+40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage temperation (\u2103)<\/p>\n<\/td>\n<td>\n<p>-25&#8230;+70<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Installation<\/p>\n<\/td>\n<td>\n<p>Terminal connection type<\/p>\n<\/td>\n<td>\n<p>Cable\/Pin-type busbar<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for cable<\/p>\n<\/td>\n<td>\n<p>16~50\/6-1\/0 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for Busbar<\/p>\n<\/td>\n<td>\n<p>16~35mm2 \u00a0\/ 6-2 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tightening torque<\/p>\n<\/td>\n<td>\n<p>3.5 N*m \u00a0\/ \u00a031 In-Ibs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mounting<\/p>\n<\/td>\n<td>\n<p>On DIN rail EN 60715 (35mm) by means of fast clip device<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connection<\/p>\n<\/td>\n<td>\n<p>From top or bottom are available<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-02-6.webp\" alt=\"RCBO JCB1LE-125 125A 6kA detail image 2\" loading=\"lazy\"><\/p>\n<p>JCB1LE-125 Dimensions<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-03-6.webp\" alt=\"RCBO JCB1LE-125 125A 6kA detail image 3\" loading=\"lazy\"><\/p>","protected":false},"excerpt":{"rendered":"<p>The JCB1LE-125 RCBOs (residual current circuit breaker with overload protection) are suitable for distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.Electronic TypeResidual current protectionOverload and short circuit protectionBreaking capacity 6kARated current up to 125A (available from 63A to 125A)Available in B Curve or C tripping curves.Tripping sensitivity: 30mA,100mA,300mAType A or Type AC are availableComplies with IEC 61009-1, EN61009-1Available in B Curve or C tripping curves.Tripping sensitivity: 30mA,100mA,300mAType A or Type AC are availableComplies with IEC 61009-1, EN61009-1<\/p>","protected":false},"featured_media":2151,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[78],"product_tag":[],"class_list":["post-2150","product","type-product","status-publish","has-post-thumbnail","product_cat-rcbo","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product\/2150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/comments?post=2150"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media\/2151"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media?parent=2150"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_brand?post=2150"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_cat?post=2150"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_tag?post=2150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}