{"id":2129,"date":"2026-07-30T11:25:46","date_gmt":"2026-07-30T03:25:46","guid":{"rendered":"https:\/\/eqsvq3fzct.wpdns.site\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1\/"},"modified":"2026-07-30T11:25:49","modified_gmt":"2026-07-30T03:25:49","slug":"jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1","status":"publish","type":"product","link":"https:\/\/w9-group.com\/ru\/product\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-n-1-1-1\/","title":{"rendered":"Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA"},"content":{"rendered":"<h2>\nIntroduction<br \/>\n<\/h2>\n<p>JCB2LE-80M4P RCBO combines RCD and MCB protection in a 4 module wide device and is operating for unbalanced loads and balanced loads, 3 phase protection in DIN rail distribution box.<\/p>\n<p>JCB2LE-80M4P RCBO (Residual Current Circuit Breaker with Overload Protection) provides residual and overload protection in one neat device. The breaking capacity is up to 6kA. The rate current is up to 80Amps. It is available in 6A, 10A, 16A, 20A, 32A, 40A, 50A, 63A,80A. It is available in A type and AC type. Type AC RCBOs are used for general purpose on AC (Alternating Current) only circuits. Type A are used for DC (Direct Current) protection. Available in 30mA,100mA,300mA tripping sensitivity. Available in B, C ,D tripping curves.<\/p>\n<p><\/p>\n<p>JCB2LE-80M4P RCBO is commonly used in applications where there is the need to combine protection against overcurrents (overload and short-circuit) and protection against earth leakage currents. They help in sensing this kind of faults and trip the circuit ensuring complete protection of the people and connected equipment<\/p>\n<p><\/p>\n<p>JCB2LE-80M4P RCBO is purposed to protect one from the risk of electrical shocks, firesand electrocution. It can also assist in sudden earth faults. The installation of an JCB2LE-80M4P RCBO ensures that a circuit trips immediately and protects you from electric shock.<\/p>\n<p>JCB2L3-80M4P comply with IEC 61009-1, EN61009-1 standard.<\/p>\n<h2>\nProduct Description<br \/>\n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-01-3.webp\" alt=\"Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 1\" loading=\"lazy\"><\/p>\n<p>Main Features<\/p>\n<p>\u25cf Electronic 4-pole<br \/>\n\u25cf Leakage Protection<br \/>\n\u25cf Overload and short circuit protection<br \/>\n\u25cf Non-linear\/load sensitive<br \/>\n\u25cf Breaking capacity up to 6kA<br \/>\n\u25cf Rated current up to 80A (available in 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A, 80A)<br \/>\n\u25cf Provide B-type and C-type tripping curves<br \/>\n\u25cf Trip sensitivity: 30mA, 100mA, 300mA<br \/>\n\u25cf Type A or AC available<br \/>\n\u25cf Insulated openings facilitate busbar installation<br \/>\n\u25cf 35mm DIN rail mounting<br \/>\n\u25cf Compatible with many types of combination head screwdrivers<br \/>\n\u25cf Meet ESV&#8217;s additional testing and verification requirements for RCBO<br \/>\n\u25cf Comply with IEC 61009-1, EN61009-1<br \/>\nThe electronic 4-pole RCBO offers comprehensive functionality to ensure strong electrical protection. It features leakage protection, overload and short-circuit protection, and non-linearity\/load sensitivity designed to protect against a wide range of electrical faults. Breaking capabilities up to 6kA and current ratings up to 80A (available in various amperages) make them suitable for a variety of applications.<br \/>\nRCBO has B-type and C-type tripping curves to choose from, and the tripping sensitivity has three options: 30mA, 100mA, and 300mA, which can meet different requirements. Additionally, it offers the flexibility of Type A or AC configurations to meet specific circuit needs.<br \/>\nThe design includes insulated openings for easy busbar installation and 35mm DIN rail mounting, ensuring easy and safe installation. In addition, it is compatible with many types of double-ended screwdrivers, simplifying maintenance and upkeep.<br \/>\nThe device meets ESV&#8217;s additional testing and validation requirements for RCBOs to ensure compliance with industry standards, including IEC 61009-1 and EN61009-1, providing safety and performance assurance.<\/p>\n<p>\nTechnical Data<\/p>\n<p>\u25cf Standard: IEC 61009-1, EN61009-1<br \/>\n\u25cf Type: Electronic<br \/>\n\u25cf Type (detected leakage waveform): A or AC available<br \/>\n\u25cf Number of poles: 4 poles<br \/>\n\u25cf Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A<br \/>\n\u25cf Rated working voltage: 400V, 415V AC<br \/>\n\u25cf Rated sensitivity I\u25b3n: 30mA, 100mA, 300mA<br \/>\n\u25cf Rated breaking capacity: 6kA<br \/>\n\u25cf Insulation voltage: 500V<br \/>\n\u25cf Rated frequency: 50\/60Hz<br \/>\n\u25cf Rated impulse withstand voltage (1.2\/50): 6kV<br \/>\n\u25cf Pollution level: 2<br \/>\n\u25cf Thermomagnetic release characteristics: B curve, C curve, D curve<br \/>\n\u25cf Mechanical life: 10,000 times<br \/>\n\u25cf Electrical life: 2000 times<br \/>\n\u25cf Protection level: IP20<br \/>\n\u25cf Ambient temperature (daily average \u226435\u2103): -5\u2103~+40\u2103<br \/>\n\u25cf Contact position indicator: green = closed, red = open<br \/>\n\u25cf Terminal connection type: cable\/U-shaped busbar\/pin busbar<br \/>\n\u25cf Installation: Mounting on DIN rail EN 60715 (35mm) via quick clamp device<br \/>\n\u25cf Recommended torque: 2.5Nm<br \/>\n\u25cf Connection method: can be connected from the top or bottom<br \/>\nElectronic RCBOs are designed to comply with a comprehensive set of technical specifications to ensure reliable and safe operation in a variety of electrical installations. It complies with IEC 61009-1 and EN61009-1 standards and complies with international safety and performance standards.<br \/>\nThe 4-pole RCBO has a rated current range from 6A to 80A and is suitable for rated operating voltages from 400V to 415V AC. It offers rated sensitivity options of 30mA, 100mA and 300mA to ensure effective protection against ground leakage currents.<br \/>\nThe RCBO has a rated breaking capacity of 6kA, an insulation voltage of 500V and is designed to withstand electrical stresses and impulses. Pollution level 2, suitable for use in various environments.<br \/>\nThe device is equipped with thermomagnetic release characteristics in B-curve, C-curve and D-curve options, providing flexibility to meet specific application requirements. The mechanical life span reaches 10,000 times and the electrical life span reaches 2,000 times, ensuring long-term reliability.<br \/>\nThe RCBO has an IP20 protection rating, which provides adequate protection against solid objects but limited protection against water intrusion. Its designed working environment temperature range is -5\u2103 to +40\u2103, suitable for a variety of working conditions.<br \/>\nRCBO is available in a variety of terminal connection types, including cable, U-busbar and pin-type busbar, and can be mounted on DIN rail EN 60715 (35mm) using quick-clamp devices. The recommended installation torque is 2.5Nm, and it can be flexibly connected from the top or bottom for easy installation and maintenance.<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\n<p>Standard<\/p>\n<\/td>\n<td>\n<p>IEC61009-1 , \u00a0EN61009-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p>Electrical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Rated current In (A)<\/p>\n<\/td>\n<td>\n<p>6, 10, 16, 20, 25, 32, 40,50,63,80<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type<\/p>\n<\/td>\n<td>\n<p>Eletronic<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type (wave form of the earth leakage sensed)<\/p>\n<\/td>\n<td>\n<p>A or AC are available<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Poles<\/p>\n<\/td>\n<td>\n<p>4 Pole<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated voltage Ue(V)<\/p>\n<\/td>\n<td>\n<p>230\/240<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated sensitivity I\u25b3n<\/p>\n<\/td>\n<td>\n<p>30mA,100mA,300mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation voltage Ui (V)<\/p>\n<\/td>\n<td>\n<p>500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated breaking capacity<\/p>\n<\/td>\n<td>\n<p>6kA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated impulse withstand voltage(1.2\/50) Uimp (V)<\/p>\n<\/td>\n<td>\n<p>6000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pollution degree<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Thermo-magnetic release characteristic<\/p>\n<\/td>\n<td>\n<p>B, C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p>Mechanical<\/p>\n<p>features<\/p>\n<\/td>\n<td>\n<p>Electrical life<\/p>\n<\/td>\n<td>\n<p>2, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mechanical life<\/p>\n<\/td>\n<td>\n<p>10, 000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Contact position indicator<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection degree<\/p>\n<\/td>\n<td>\n<p>IP20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reference temperature for setting of thermal element(\u2103)<\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ambient temperature (with daily average \u226435\u2103)<\/p>\n<\/td>\n<td>\n<p>-5&#8230;+40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage temperation (\u2103)<\/p>\n<\/td>\n<td>\n<p>-25&#8230;+70<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Installation<\/p>\n<\/td>\n<td>\n<p>Terminal connection type<\/p>\n<\/td>\n<td>\n<p>Cable\/U-type busbar\/Pin-type busbar<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for cable<\/p>\n<\/td>\n<td>\n<p>25mm2\u00a0\u00a0\/ 18-4 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Terminal size top\/bottom for Busbar<\/p>\n<\/td>\n<td>\n<p>10mm2 \u00a0\/ 18-8 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tightening torque<\/p>\n<\/td>\n<td>\n<p>2.5 N*m \u00a0\/ \u00a022 In-Ibs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mounting<\/p>\n<\/td>\n<td>\n<p>On DIN rail EN 60715 (35mm) by means of fast clip device<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connection<\/p>\n<\/td>\n<td>\n<p>From top<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-02-3.webp\" alt=\"Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 2\" loading=\"lazy\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/w9-group.com\/wp-content\/uploads\/2026\/07\/jcr2-63-2-pole-rcbo-for-ev-charger-10ka-differential-circuit-breaker-1p-detail-03-3.webp\" alt=\"Residual Current Circuit Breaker JCB2LE-4E 4P 4 Pole RCBO 6kA detail image 3\" loading=\"lazy\"><\/p>\n<p>Respect the environment \u2013 \u200b\u200bcomply with EU directives:<br \/>\nIn addition to complying with Directive 2002\/95\/EC of January 27, 2003 (known as &#8220;RoHS&#8221;), this directive restricts the use of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated compounds. Phenyl ether (PBDE) brominated flame retardants, our commitment to environmental responsibility extends to compliance with Directive 91\/338\/EEC of 18 June 1991 and Decree No. 94-647 of 27 June 2007.<\/p>\n<p>We ensure that our MCCB production lines comply with these directives, demonstrating our commitment to sustainable and environmentally friendly manufacturing practices. By complying with these regulations, we contribute to protecting the environment and the health and safety of our customers and communities. Our commitment to environmental compliance is evident in every aspect of our production process, from material sourcing to manufacturing and distribution.<\/p>","protected":false},"excerpt":{"rendered":"<p>The JCB2LE-4E RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential housesElectronic TypeResidual current (rcd) protectionOverload and short circuit protectionBreaking capacity 6kARated current up to 80A (available from 6A to 80A)Available in B or C tripping curvesType A or Type AC are availableTripping sensitivity: 30mA,100mA,300mAComplies with IEC 61009-1, EN61009-1<\/p>","protected":false},"featured_media":2130,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[78],"product_tag":[],"class_list":["post-2129","product","type-product","status-publish","has-post-thumbnail","product_cat-rcbo","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product\/2129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/comments?post=2129"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media\/2130"}],"wp:attachment":[{"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/media?parent=2129"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_brand?post=2129"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_cat?post=2129"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/w9-group.com\/ru\/wp-json\/wp\/v2\/product_tag?post=2129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}